PLATE B-11
STRENGTH OF U.S. STANDARD
BOLTS FROM ¼" TO 2" DIAMETER
BOLT | AREAS | TENSILE STRENGTH, LBS. | SHEARING STRENGTH, LBS. | |||||||
Diameter of Bolts, Inches |
Number of Threads per Inch | Full Bolt, Sq. In. | Bottom of Thread, Sq. In. | At 10,000 Lbs. Per Sq. In. | At 12,500 Lbs. Per Sq. In. | At 17,500 Lbs. Per Sq. In. | FULL BOLT | BOTTOM OF THREAD | ||
At 7,500 Lbs. Per Sq. In. | At 10,000 Lbs. Per Sq. In. | At 7,500 Lbs. Per Sq. In. | At 10,000 Lbs. Per Sq. In. | |||||||
¼ | 20 | 0.049 | 0.027 | 270 | 340 | 470 | 380 | 490 | 200 | 270 |
5/16 | 18 | 0.077 | 0.045 | 450 | 570 | 790 | 580 | 770 | 340 | 450 |
3/8 | 16 | 0.110 | 0.068 | 680 | 850 | 1,190 | 830 | 1,100 | 510 | 680 |
7/16 | 14 | 0.150 | 0.093 | 930 | 1,170 | 1,630 | 1,130 | 1,500 | 700 | 930 |
½ | 13 | 0.196 | .126 | 1,260 | 1,570 | 2,200 | 1,470 | 1.960 | 940 | 1,260 |
9/16 | 12 | 0.248 | 0.162 | 1,620 | 2,030 | 2,840 | 1,860 | 2,480 | 1,220 | 1,620 |
5/8 | 11 | 0.307 | 0.202 | 2,020 | 2,520 | 3,530 | 2,300 | 3,070 | 1,510 | 2,020 |
¾ | 10 | 0.442 | 0.302 | 3,020 | 3,770 | 5,290 | 3,310 | 4,420 | 2,270 | 3,020 |
7/8 | 9 | 0.601 | 0.419 | 4,190 | 5,240 | 7,340 | 4,510 | 6,010 | 3,150 | 4,190 |
1 | 8 | 0.785 | 0.551 | 5,510 | 6,890 | 9,640 | 5,890 | 7,850 | 4,130 | 5,510 |
1 1/8 | 7 | 0.994 | 0.693 | 6,990 | 8,660 | 12,130 | 7,450 | 9,940 | 5,200 | 6,930 |
1 ¼ | 7 | 1.227 | 0.890 | 8,890 | 11,120 | 15,50 | 9,200 | 12,270 | 6,670 | 8,900 |
1 3/8 | 6 | 1.435 | 1.054 | 10,540 | 13,180 | 18,450 | 11,140 | 14,850 | 7,910 | 10,540 |
1 ½ | 6 | 1.767 | 1.294 | 12,940 | 16,170 | 22,640 | 13,250 | 17,60 | 9,700 | 12,940 |
1 5/8 | 5 ½ | 2.074 | 1.515 | 15,150 | 18,940 | 26,510 | 15,550 | 20,740 | 11,360 | 15,150 |
1 ¾ | 5 | 2.405 | 1.745 | 17,450 | 21,800 | 30,520 | 18,040 | 24,050 | 13,080 | 17,440 |
1 7/8 | 5 | 2.761 | 2.049 | 20,490 | 25,610 | 35,860 | 20,710 | 27,610 | 15,370 | 20,490 |
2 | 4 ½ | 3.142 | 2.300 | 23,000 | 28,750 | 40,500 | 23,560 | 31,420 | 17,250 | 23,000 |