This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 13. Cranes and Other Hoisting Equipment
Article 100. Inspection and Maintenance

Return to index
New query



§5037. Wire Rope -- Selection and Installation Criteria.


(a) Selection of replacement wire rope shall be in accordance with the recommendations of the crane manufacturer or a qualified person.
(b) Wire rope shall be compatible with the safe functioning of the equipment.
(c) Rotation resistant ropes. Rotation resistant ropes shall not be used for boom hoist reeving, except where the requirements of the crane manufacturer state otherwise.
(d) End terminations on wire rope shall be installed in accordance with the termination or rope manufacturer's specification.

Credits

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
History
1. New section filed 7-26-2022; operative 7-26-2022 pursuant to Government Code section 11343.4(b)(3) (Register 2022, No. 30). Filing deadline specified in Government Code section 11349.3(a) extended 60 calendar days pursuant to Executive Order N-40-20 and an additional 60 calendar days pursuant to Executive Order N-71-20.