This information is provided free of charge by the Department of Industrial Relations
from its web site at
www.dir.ca.gov. These regulations are for the
convenience of the user and no representation or warranty is made that the information
is current or accurate. See full disclaimer at
https://www.dir.ca.gov/od_pub/disclaimer.html.
Subchapter 7. General Industry Safety Orders
Group 13. Cranes and Other Hoisting Equipment
Article 98. Operating Rules
ยง4995. Riding Loads on Derricks, Hoists, or Cranes.
No employee shall be permitted to ride on loads, hooks, or slings of any derrick, hoist, or crane.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 4-11-94; operative 5-11-94 (Register 94, No. 15). For prior history, see Register 86, No. 39.
Go Back to Article 98 Table of Contents