This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 8. Points of Operation and Other Hazardous Parts of Machinery
Article 70. Chemical Industry Machines
Return to index
New query

ยง4566. Extractors (Screw Cover Type).


(a) Screw cover type extractors shall be equipped with a metal cover of at least No. 20 gage or its equivalent which shall cover the entire opening to the outer shell and shall be kept in its closed position when the extractor is in motion.

(b) The cover for the revolving container shall be held securely in place by a locknut on the spindle or the container shall revolve in the direction that will tend to tighten the spindle nuts.