This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 3. General Plant Equipment and Special Operations
Article 19. Automotive Lifts
Return to index
New query

§3547. Working Area Under Lifts.


(a) No slots or abrupt recesses in excess of 2 1/4 inches in width (unless closable by integral hinged flat covers) or raised floor obstructions for re-- ceiving the lift frame and rails shall be permitted in the floor under the lift.

NOTE: The floor may be recessed to receive the rails providing the slope into the lowest part of the recess does not exceed 1 inch in 4 inches and provided also the inclined surfaces are constructed and surfaced so as to reduce slipping hazards.

(b) Floor surfaces under the lift shall be kept reasonably free of oil or grease to minimize the slipping hazards.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.