| Return to index New query |
(a) Car frames and platforms shall be constructed of metal or a combination of metal and wood having a factor of safety of not less than 5 based on rated load.
(b) Cast iron shall not be used in any member of the car frame or platform other than for guides or guide shoe brackets.
(Title 24, Part 7, Section 7-3093.8)
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).
Go Back to Article 15 Table of Contents