Skip to Main Content


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts
Return to index
New query

§3093.20. Opening of the Brake Circuit on Safety Application.


Where a speed governor is used, the motor circuit and the brake circuit shall be opened before or at the time that the safety applies.

(Title 24, Part 7, Section 7-3093.20)

NOTE

Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).

2. Amendment of section heading filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).

Go BackGo Back to Article 15 Table of Contents