Skip to Main Content


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 6. Elevator Safety Orders
Article 12.3. Special Purpose Personnel Elevators
Return to index
New query

§3085.3. Horizontal Car and Counterweight Clearances [Rule 1500.2].


(a) Horizontal car and counterweight clearances shall conform to the requirements of Section 3018 and subsection 3085.6(a).

(b) Where the distance between the car sill and the facia, where provided, or the building structure exceeds 7 in. (178 mm), the car door or gate shall be equipped with an interlock or contact lock.

(Title 24, Part 7, Section 7-3085.3)

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. Editorial correction of subsection (b) (Register 95, No. 34).

2. Editorial correction of Note (Register 97, No. 25).

Go BackGo Back to Article 12.3 Table of Contents