(a) Scope. The elevator industry and the material handling industry, both of which are subject to these orders, use many words and terms that have meanings unique to their respective endeavors. Definitions are included to standardize nomenclature and improve communication between inspectors, mechanics, architects, engineers, and owners. Oral and written interchanges are enhanced when both parties understand a given term or word to have a specific meaning.
(b) List of Definitions. The following definitions shall be accepted as the meaning of the various terms as used in these regulations:
Acceleration. The operation of advancing the elevator drive motor speed from zero to normal operating speed.
Alteration. Any change or addition to the equipment other than ordinary repairs or replacements.
Alternate Level. See Level, Alternate.
Angle of Contact. That portion of a sheave contacted by a rope. Measured in degrees of contact. Sometimes referred to as angle of wrap or arc of contact.
Annunciator, Car. An electrical device in the car which indicates visually the landings at which an elevator landing signal registering device has been actuated.
Approved Device. An approved device is one on which a written approval for use in the State of California has been issued by the Division of Industrial Safety.
Apron. See Platform Guard.
Astragal. A molding on the leading edge of hoistway and car doors. Usually a rubber molding extending the full height on center opening doors, and either metal or rubber running the full width of the upper panel on biparting freight type doors. It is furnished to reduce the effects of injury, should something get caught between door panels and quiet the operation of the doors.
Authorized Personnel. Persons who have been instructed in the operation and/or maintenance of the equipment and designated by the owner to use or maintain the equipment.
Automatic Transfer Device. See under Material Handling Devices.
Backlash. Excessive clearance between the teeth of the worm and worm gear of a geared machine; it permits a rocking action of the drive sheave or gear when the worm is held stationary.
Basic Safety Circuit. A portion of the elevator control wiring that includes a number of mechanical switch contacts and relay contacts in series. Usually includes the final limits, emergency stop button, governor contacts and a safety-operated switch. The cause of operation of any one of these contacts constitutes a possible hazardous operation of the elevator and therefore stops all elevator operation. Also called the emergency circuit.
Buffer. A device designed to stop a descending car or counterweight beyond its normal limit of travel by storing or by absorbing and dissipating the kinetic energy of the car or counterweight.
(A) Oil Buffer. A buffer using oil as a medium which absorbs and dissipates the kinetic energy of the descending car or counterweight.
(B) Oil Buffer Stroke. The oil-displacing movement of the buffer plunger or piston.
(C) Spring Buffer. A buffer which stores in a spring the kinetic energy of the descending car or counterweight.
(D) Spring-Buffer Load Rating. The load required to compress the spring an amount equal to its stroke.
(E) Spring-Buffer Stroke. The distance the contact end of the spring can move under a compressive load until all coils are essentially in contact.
Bumper. A device, other than an oil or spring buffer, designed to stop a descending car or counterweight beyond its normal limit of travel by absorbing the impact.
Cam. A steel angle beveled at both ends and fastened to the guide rails to operate terminal switches mounted on the car. A steel angle beveled at both ends fastened to the car to operate terminal switches in the hoistway. A steel angle mounted on the car to operate a hoistway floor selector. A movable steel bar or angle mounted on a car to unlock hoistway door interlocks. A device for converting regular rotary motion into irregular rotary motion or reciprocating motion.
Car, Elevator. The load-carrying unit, including its platform, car frame, enclosure, and car door or gate.
Car, Material Lift. See under Material Handling Devices.
Car Door or Gate Electric Contact. An electrical device, the function of which is to prevent the operation of the driving machine by the normal operating device unless the car door or gate is in the closed position.
Car Enclosure. The top and the walls of the car resting on and attached to the car platform.
Car Frame (Sling). The supporting frame to which the car platform, upper and lower sets of guide shoes, car safety and hoisting ropes or rope sheaves of a cable elevator are usually attached or the plunger or cylinder of a direct plunger elevator are attached.
Car Frame, Overslung. A car frame to which the hoisting rope fastenings or hoisting rope sheaves are attached to the crosshead or top member of the car frame.
Car Frame, Underslung. A car frame to which the hoisting rope fastenings or hoisting rope sheaves are attached at or below the car platform.
Car Frame, Sub-Post. A car frame, all of whose members are located below the car platform.
Car Frame, Offset. A car frame sufficiently offset from the center of the platform to require special design and construction not covered by the formulas in Article 18.
Car Platform. The structure which forms the floor of the car and which directly supports the load.
Car Stop Switch. A device located in the car which, when manually operated, causes the electric power to be removed from the driving machine motor and brake of an electric elevator or from the electrically operated valves and pump motor of a hydraulic elevator.
C.C.R. means the California Code of Regulations.
Clearance, Bottom Car. The clear vertical distance from the pit floor to the lowest structural or mechanical part, equipment or device installed beneath the car platform, except guide shoes or rollers, safety jaw assemblies and platform aprons or guards, or other equipment located within 12 inches horizontally from the edge of the platform, when the car rests on its fully compressed buffer.
Clearance, Top Car. The shortest vertical distance between the top of the car crosshead, or between the top of the car which ever is higher, and the nearest part of the overhead structure or any other obstruction when the car floor is level with the top terminal landing.
Clearance, Top Counterweight. The shortest vertical distance between any part of the counterweight structure and the nearest part of the overhead structure or any other obstruction when the car floor is level with the bottom terminal landing.
Collision Switch. See under Earthquake Protection Devices.
Compensating Rope Sheave Switch. A device which automatically causes the electric power to be removed from the elevator motor and brake when the compensating sheave approaches its upper or lower limit of travel.
Computer. An electronic device in the common signal system of an operatorless group of elevators. It monitors the operation of and demand on the system and initiates changes to alter the operation of the bank of elevators to satisfy the traffic conditions prevailing at any time.
(A) Binary Counter. A counter circuit that counts the number of pulses entering a circuit. On a specific count, the counter automatically resets.
(B) Central Processing Unit (CPU). The portion of a computer that performs all arithmetic operations, logic operations and data manipulation. It retrieves control instructions stored in the computer's memory then decodes, interprets and implements them.
(C) Input/Output (I/O). The section of a computer by which the microprocessor communicates with a variety of devices, such as other microprocessors in the system. Input/Output devices can also be conventional hardware such as a keyboard for input and a television screen displaying output.
(D) Logic. The result of planning a data-processing system or of synthesizing a network of logic elements to perform a specified function. Pertaining to the type of physical realization of logic elements used, for example, diode logic.
(E) Logic Board. An assembly of decision making circuits on a printed circuit mounting board.
(F) Microcomputer: A computer system based on a microprocessor Central Processing Unit.
(G) Microprocessor: The Central Processing Unit (CPU) of a microcomputer, it is the device that contains the silicon chip which decodes instructions and controls the operation of the microcomputer and the flow of information within it.
(H) Peripherals. Subsystems or components of a computer, other than memory, which exchange information with the CPU, usually through an input/output port.
(I) PROM (Programmable Read Only Memory). A variation of the ROM concept which allows the memory to be manufactured as "blank." The information is later installed by blowing fusable links in the structure.
(J) RAM (Random Access Memory). A collection of "read/write" memory chips that store data and can be modified while the computer is operating. Information can be "written" (stored) and "read" (recalled) at a later time in a system using RAM.
(K) ROM (Read Only Memory). The part of a computer memory system that stores permanent information. A ROM chip cannot be written on or changed. During manufacture, information is permanently encoded as a part of its physical structure. It is a source of information only.
(L) Software Based: A system which uses programmed instructions rather than mechanical or electronic devices to control operations. In a software based system, the path taken by signals, or the decisions the system makes, is determined by instructions rather than physical linkages between hardware.
Control. The system governing the starting, stopping, direction of motion, acceleration, speed, and retardation of the moving member.
(A) Generator-Field Control. A system of control which is accomplished by the use of an individual generator for each elevator or dumbwaiter wherein the voltage applied to the driving-machine motor is adjusted by varying the strength and direction of the generator field.
(B) Multivoltage Control. A system of control which is accomplished by impressing successively on the armature of the driving-machine motor a number of substantially fixed voltages such as may be obtained from multicommutator generators common to a group of elevators.
(C) Rheostatic Control. A system of control which is accomplished by varying resistance or reactance, or both, in the armature or field circuit, or both, of the driving-machine motor.
(D) Single-Speed Alternating Current Control. A control for a driving-machine induction motor which is arranged to run at a single speed.
(E) Two-Speed Alternating Current Control. A control for a two-speed driving-machine induction motor which is arranged to run at two different synchronous speeds by connecting the motor windings so as to obtain different numbers of poles.
Control, Static. A control system in which control functions are performed by solid state devices.
Controller. A device, or group of devices, which serves to control in some predetermined manner the apparatus to which it is connected.
Conveyor, Reciprocating. See under Material Handling Devices.
Derailment Switch. See under Earthquake Protection Devices.
Designated Level. See Level, Designated.
Dispatching Device, Elevator Automatic. A device, the principal function of which is to operate a signal in the car to indicate when the car should leave a designated landing, or to actuate its starting mechanism when the car is at a designated landing.
Division. The word "Division" when used in these regulations shall mean the Division of Occupational Safety and Health, State of California.
Door or Gate, Car or Hoistway. The sliding portion of the car or the hinged or sliding portion in the hoistway enclosure which closes the opening giving access to the car or to the landing.
(A) Biparting Door. A vertically sliding door, consisting of two or more sections so arranged that the sections or groups of sections open away from each other and so interconnected that all sections operate simultaneously.
(B) Center-Opening Door. A horizontally sliding or horizontally swinging door consisting of two or more sections so arranged that the sections or groups of sections open away from each other. Horizontally sliding center-opening doors are interconnected so that all sections operate simultaneously.
Door or Gate Closer. A device which closes a hoistway door or a car door or gate by means of a spring or by gravity.
Door or Gate, Power-Operated. A hoistway door or a car door or gate which is opened and closed by a door or gate power operator.
Door or Gate Power Operator. A device or assembly of devices which opens a hoistway door or a car door or gate or both by power other than by hand, gravity, springs, or the movement of the car; and which closes them by power other than by hand, gravity, or the movement of the car.
Door or Gate, Self-Closing. A manually opened hoistway door or a car door or gate which closes when released.
Door or Gate, Manually Operated. A door or gate which is opened and closed by hand.
Door or Gate, Semiautomatic. A door or gate which is opened manually and which closes automatically as the car leaves the landing.
Door or Gate, Full Automatic. A door or gate which is opened automatically by the action of the elevator car approaching the landing and closed by gravity as the car leaves the landing.
Doors, Sidewalk. Sidewalk doors are two section center-opening panels hinged to the sidewalk or other approximately horizontal surface that the sidewalk elevator penetrates and that cover or close the entire opening of the hoistway.
Dumbwaiter. See under Material Handling Devices.
Undercounter Dumbwaiter. See under Material Handling Devices.
Earthquake Protection Devices. A device or group of devices which serve to regulate the operation of an elevator in a predetermined manner during or after an earthquake, consisting of:
(A) Collision Switch. A device actuated by the car or counterweight to provide information to the control that a collision between the car and the counterweight is imminent.
(B) Derailment Switch. A device actuated by the derailment of the counterweight at any point in the hoistway to provide information to the control that the counterweight has left its guides.
(C) Seismic Switch. A device activated by ground movement to provide information to the control system that a potentially damaging earthquake is imminent.
(Title 24, part 7, section 7-3009).
Elevator. A hoisting and lowering mechanism which moves a car or platform in fixed guides in a substantially vertical direction and which is designed to carry passengers or freight, or both, between two or more fixed landings.
A hoisting mechanism, such as a portable hoist or a tiering machine, used to elevate or lower material between two or more fixed landings and used or fixed in a permanent location will be classed as an elevator.
A hydraulic hoisting mechanism used to elevate or lower material between two or more fixed landings and used or fixed in a permanent location will be classed as an elevator.
Elevators are classified by the following types:
(A) Auxiliary Power Elevator. An auxiliary power elevator is one having a source of mechanical power, such as shafting, in common with other machinery.
(B) Carriage Type Elevator. A carriage type elevator is a hand freight elevator with a platform having no suspension sling frame, but which is raised by cables dropping from winding drums or sheaves over the wellway and connected to the platform at four or more points.
(C) Double Belt Elevator. A double belt elevator is an elevator in which the source of power is connected to the machine by a double belt system employing idling pulleys and a belt shifter, and in which the reversal of direction of the elevator is accomplished by shifting the belts without reversing the prime mover.
(D) Electric Elevator. A power elevator in which the motion of the car is obtained through an electric motor applied to the elevator without an intervening hydraulic system.
(E) Gravity Elevator. An elevator utilizing gravity to move the car.
(F) Hand Elevator. An elevator utilizing manual energy to move the car.
(G) Hand Power Man Platform Elevator. A hand power man platform elevator is a counter balanced car in guides, so arranged that a man on the platform may, by holding the brake in the off position, pull himself and the car up or down by means of a rope secured at the top and bottom of the hoistway.
(H) Hatchway Type Elevator. A hatchway type elevator is an elevator running through floor openings provided with hatch covers, each of which is opened automatically as the car approaches the landing and is closed automatically as the car leaves the landing.
(I) Hydraulic Elevator. A power elevator where the energy is applied by means of liquid under pressure to a cylinder or plunger.
1. Direct-Plunger Elevator. A hydraulic elevator where the cylinder or plunger acts directly on the platform or car frame without intermediate linkage.
2. Hydraulic Maintained-Pressure Elevator. A hydraulic elevator where liquid under pressure is available at all times for transfer into the cylinder.
3. Hydraulic Telescopic Plunger Elevator. A direct-plunger hydraulic elevator having a set of co-axial plungers.
4. Hydro-Electric or Electro-Hydraulic Elevator. A hydraulic elevator where liquid is pumped under pressure directly into the cylinder by a pump driven by an electric motor.
5. Indirect Plunger Elevator. See Roped Hydraulic Elevator.
6. Roped Hydraulic Elevator. a.k.a. "Indirect Plunger Hydraulic Elevator." A hydraulic elevator having its piston connected to the car with wire ropes.
(J) Inclined Elevator. An elevator which travels at an angle of inclination of 70 degrees or less from the horizontal.
(K) Multideck Elevator. An elevator having two or more compartments located one immediately above the other.
(L) Observation Type Elevator. An observation type elevator is an elevator designed and arranged to travel in a hoistway that is less than fully enclosed. These elevators are typically arranged to provide a view.
(M) Platform Type Elevator. A platform type elevator is an elevator in which the platform is directly supported at three or more points by suspension members which are relied upon to maintain the platform substantially level.
(N) Power Elevator. An elevator utilizing energy other than gravitational or manual to move the car.
(O) Rack and Pinion Elevator. A rack and pinion elevator is an elevator raised and lowered by means of a rack and pinion.
(P) Screw Column Type Elevator. A screw column type elevator is an elevator raised and lowered by means of a threaded nut revolving on a spiral worm or the worm revolving inside the nut or both.
(Q) Single Belt Elevator. A single belt elevator is an elevator in which the prime mover is connected to the machine by a single belt or multiple belt, all parts of which act together, and in which the reversal of direction of the elevator is accomplished by reversing the prime mover.
(R) Steam Elevator. A steam elevator is an elevator in which the motion of the car is obtained from a steam engine directly applied to the elevator machinery.
Elevator, Construction. An elevator, used temporarily during construction, alteration or demolition of buildings or structures, for use by workers or persons connected with or related to the building project.
Elevator, Freight. An elevator used exclusively for carrying freight and on which only the operator and the persons necessary for unloading and loading the freight are permitted to ride.
Elevator, Passenger. An elevator used primarily to carry persons.
Elevator, Private Residence. A passenger elevator which is limited in size, capacity, rise, and speed, and is installed in a private residence or in a multiple dwelling as a means of access to a private residence.
Elevator, Sidewalk. A freight elevator which operates through an area (usually the sidewalk) exterior to the building or structure and floor levels below. The exterior area (sidewalk) is protected by sidewalk doors that are opened by the car as it ascends. Sidewalks elevators without sidewalk doors are permissible (See Section 3075) only where the top landing is at ground level.
Elevator, Special Purpose Personnel. A special purpose personnel elevator is an elevator for use by authorized personnel and their tools or equipment only, and where location, structure and limited usage are the determining factors.
Elevator, Stairway. See Inclined Stairway Chairlift.
Emergency Stop Switch. See Car Stop Switch.
Entrance, Elevator and Dumbwaiter. The protective assembly which closes the openings in the hoistway enclosure normally used for loading and unloading.
(A) Horizontally Sliding. An entrance in which the panel(s) or door(s) slides horizontally.
(B) Swing. An entrance in which the panel(s) or door(s) swings around vertical hinges.
(C) Vertical Sliding. An entrance in which the panel(s) or door(s) slides vertically.
Escalator or Electric Stairway. A moving, inclined, continuous stairway used for raising or lowering passengers.
The following definitions are applicable to escalators only.
1. Balustrade. The side of an escalator extending above the steps. It includes skirt panels, interior panels, decks and handrails.
2. Deck. The transverse members of the balustrade. A high deck is located immediately below the handrail stand. A low deck is located immediately above the skirt panel, having an interior or exterior section, or both.
3. Exterior Escalator Panel. The panel enclosing the exterior side of the balustrade.
4. Interior Escalator Panel. The panel located between the skirt and the handrail stand.
5. Molding. The connecting seams between the various portions of the balustrade.
6. Newel. The balustrade termination at the landing.
7. Newel Base. The panel located immediately under the newel.
8. Skirt. The panels located immediately adjacent to the steps or treadway.
9. Tandem Operation. Escalator used in series with common intermediate landings.
Freight Platform Hoist. A freight platform hoist is a freight type hoist having no car enclosure, no hoistway enclosure and a rise of not more than 5 feet (1.52 m) in or adjacent to a loading platform or similar landing and serving two permanent landings.
Gurney Lift. See under Special Access Lifts.
Hand Power Man Platform. See under Elevators.
Hatch, Hatchway. See Hoistway. In early elevator usage a hatch or hatchway was a framed opening in a floor with a hinged or removable cover. Now incorrectly used to describe or designate an elevator hoistway.
Hoistway Access Switch. A switch located at a landing, the function of which is to permit operation of the car with the hoistway door at this landing and the car door or gate open, in order to permit access to the top of the car or to the pit.
Hoistway, Elevator or Dumbwaiter. A shaftway for the travel of one or more elevators or dumbwaiters. It includes the pit and terminates at the underside of the overhead machinery space floor or grating, or at the underside of the roof where there is no machinery over the hoistway.
Hoistway Enclosure. A fixed structure, consisting of vertical walls or partitions, which isolates the hoistway from all other parts of the building or from an adjacent hoistway and in which the hoistway doors and door assemblies are installed.
Hoistway Door or Gate Locking Device. See hoistway door interlock or contact lock.
Hoistway Unit System. A series of hoistway door interlocks, hoistway door electric contacts, or hoistway door combination mechanical locks and electric contacts, or a combination thereof, the function of which is to prevent operation of the driving machine by the normal operating device unless all hoistway doors are in the closed position and, where so required by these regulations, are locked in the closed position.
(A) Closed Position. See sections 3021(g) and 3021(h) for limitations of "closed position" for the various combinations of doors, gates, and locking devices.
(B) Hoistway Door Interlock. A device having two related and interdependent functions which prevent the operation of the driving machine by the normal operating device unless the hoistway door is locked in the closed position, and prevent the opening of the hoistway door from the landing side unless the car is within the landing zone and is either stopped or being stopped.
(C) Contact Lock or Combination Mechanical Lock and Electric Contact. A combination mechanical and electrical device the two related, but entirely independent, functions of which prevent operation of the driving machine by the normal operating device unless the hoistway gate is in the closed position, and lock the hoistway gate in the closed position and prevent it from being opened from the landing side unless the car is within the landing zone.
Hoistway Door or Gate Electric Contact. An electrical device, the function of which is to prevent operation of the driving machine by the normal operating device unless the hoistway door is in the closed position.
Hoistway Gate Separate Mechanical Lock. A mechanical device, the function of which is to lock a hoistway gate in the closed position after the car leaves a landing and prevent the gate from being opened from the landing side unless the car is within the landing zone.
Hoistway Door Interlock Retiring Cam Device. A hoistway door interlock retiring cam is a device which actuates the locking mechanism of a type of hoistway door interlock by the action of a retractable cam.
Idler Sheave: A grooved sheave used to guide or apply tension to a rope or cord.
Inclined Lift. See Inclined Elevator under Elevator.
Inclined Stairway Chairlift. a.k.a. "Stairway Elevator." See under Special Access Lifts.
Inclined Wheelchair Lift. See under Special Access Lifts.
Jamb. Any one of the three members constituting an elevator entrance frame, head jamb, strike jamb, and return jamb.
Kinetic Energy. The kind of energy a body has by virtue of its motion.
L. C. means the California Labor Code.
Landing, Elevator. That portion of a floor, balcony, or platform used to receive and discharge passengers or freight. Although the vertical level is normally fixed, there are instances where the landing is arranged to vary vertically to satisfy given conditions.
Landing, Bottom Terminal. The lowest landing served by the elevator which is equipped with a hoistway door and hoistway door locking device which permits egress from the hoistway side.
Landing, Top Terminal. The highest landing served by the elevator which is equipped with a hoistway door and hoistway door locking device which permits egress from the hoistway side.
Level, Alternate. The floor or landing selected as the one to which the elevator(s) are to be dispatched by activation of the sensing device permitted by section 3041(c)(1)(B)(2).
Level, Designated. The floor or landing selected as the one to which the elevator(s) are to be dispatched by the on position of the switch required by section 3041(c)(1)(A) and the landing where the switch is intended to be located.
Leveling Device, Elevator Car. Any mechanism which will either automatically or under control of the operator move the car within the leveling zone toward the landing only, and automatically stop it at the landing.
Leveling Device, One-Way Automatic. A device which corrects the car level only in case of under-run of the car but will not maintain the level during loading and unloading.
Leveling Device, Two-Way Automatic Maintaining. A device which corrects the car level on both under-run and over-run and maintains the level during loading and unloading.
Leveling Device, Two-Way Automatic Nonmaintaining. A device which corrects the car level on both under-run and over-run but will not maintain the level during loading and unloading.
Leveling Zone. The limited distance above or below an elevator landing within which the leveling device may cause movement of the car toward the landing independently of the hoistway door interlock or car door or gate contact.
Machine, Driving. The power unit which applies the energy necessary to raise and lower an elevator or dumbwaiter car or to drive an escalator, moving walk, or an inclined lift.
(A) Chain-Drive Machine. An indirect-drive machine having a chain as the connecting means.
(B) Direct-Drive Machine. An electric driving machine, the motor of which is directly connected mechanically to the driving sheave, drum, or shaft without the use of belts or chain, either with or without intermediate gears.
(C) Electric Driving Machine. One where the energy is applied by an electric motor. It includes the motor and brake and the driving sheave or drum, together with its connecting gearing, belt or chain, if any.
(D) Geared-Drive Machine. A direct drive machine in which the energy is transmitted from the motor to the driving sheave, drum, or shaft through gearing.
(E) Hydraulic Driving Machine. One in which the energy is applied by means of a liquid under pressure to a cylinder equipped with a plunger or piston.
(F) Hydroelectric Driving Machine. One in which the liquid is pumped under pressure directly into the cylinder by a pump driven by an electric motor without an intervening accumulator between the pump and the cylinder.
(G) Indirect-Drive Machine. An electric driving machine, the motor of which is connected indirectly to the drive sheave, drum, or shaft by means of a belt or chain through intermediate gears.
(H) Roped Hydraulic Driving Machine. One in which the energy is applied by a piston connected to the car with wire ropes, which operates in a cylinder under hydraulic pressure. It includes the cylinder, the piston, and multiplying sheaves, if any, and their guides.
(I) Screw Machine. An electric driving machine, the motor of which drives a nut on a vertical screw or rotates a vertical screw to raise or lower an elevator car.
(J) Traction Machine. A direct-drive machine in which the motion of the car is obtained through friction between the suspension ropes and a traction sheave.
1. Geared-Traction Machine. A geared-drive traction machine.
2. Gearless-Traction Machine. A traction machine, without intermediate gearing, which has the traction sheave and the brake drum mounted directly on the motor shaft.
(K) Winding-Drum Machine. A geared-drive machine in which the hoisting ropes are fastened to and wind on a drum.
(L) Worm-Geared Machine. A direct-drive machine in which the energy from the motor is transmitted to the driving sheave or drum through worm gearing.
May. The term "may" where used shall be construed as permissive.
Manlift. A device consisting of a power driven endless belt moving in one direction only, and provided with steps or platforms and handholds attached to it for the transportation of personnel from floor to floor.
Manlift, Handhold (handgrip). A handhold is a device attached to a belt which can be grasped by the passenger to provide a means of maintaining balance.
(A) Open type. One which has a handgrip surface fully exposed and capable of being encircled by the passenger's fingers.
(B) Closed type. A cup-shaped device, open at the top in the direction of travel of the step for which it is to be used, and closed at the bottom, into which the passenger may place his fingers.
Manlift, Limit switch. A device the purpose of which is to cut off the power to the motor and apply the brake to stop the carrier in the event that a loaded step passes the terminal landing.
Manlift, Rated speed. Rated speed is the speed for which the device is designed and installed.
Manlift, Split-rail switch. An electric limit switch operated mechanically by the rollers on the manlift steps. It consists of an additional hinged or "split" rail, mounted on the regular guide rail, over which the step rollers pass. It is spring loaded in the "split" position. If the step supports no load, the rollers will "bump" over the switch; if a loaded step should pass over the section, the split rail will be forced straight, tripping the switch and opening the electrical circuit.
Manlift, Step (platform). A step is a passenger carrying unit.
Manlift, Travel. The travel is the distance between the centers of the top and bottom pulleys.
Material Lift. See under Material Handling Devices.
Material Handling Devices. A hoisting or lowering mechanism which moves a car or platform in guides between two or more fixed landings and which is designed to carry inanimate objects only. Material Handling Devices are classified by the following types:
(A) Dumbwaiter. A dumbwaiter is an elevator, the floor area of which does not exceed 9 square feet, whose total inside height, whether or not provided with fixed or removable shelves, does not exceed 4 feet, the capacity of which does not exceed 300 pounds, and which is used exclusively for carrying materials.
1. Undercounter Dumbwaiter. One which has its top terminal landing located underneath a counter and which serves only this landing and the bottom terminal landing.
(B) Material Lift. A hoisting and lowering mechanism which would normally be classified as an elevator but with modifications to adapt it for the automatic movement of material by means of an integrally mounted automatic transfer device.
1. Automatic Transfer Device. A mechanism which automatically moves a load consisting of a cart, tote box, pallet, wheeled vehicle, box or similar object to and from the platform of the lift.
2. Restricted Area (Applicable to article 12.1). An area through which the loads carried by the material lift travel by automatic means. The area shall extend in front of the entrance to the lift a distance not less than that equal to the length of the load plus 4 feet and separated from the unrestricted area by a standard guardrail or equivalent barrier. The end of the restricted area where not guarded shall be marked with a yellow line on the floor.
3. Car, Material Lift. The load carrying unit including the car frame, enclosure and transfer device.
(C) Reciprocating Conveyor. A conveyor where the carrier pusher moves forward and back, or up and down in the same place.
1. Inclined Reciprocating Conveyer. A reciprocating power or gravity actuated unit (not designed to carry passengers or an operator) that receives only inanimate objects on a carrier. These units operate on inclines generally in the range of 30 deg. to 70 deg. from the horizontal.
2. Vertical Reciprocating Conveyor. A reciprocating power or gravity actuated unit (not designed to carry passengers or an operator) that receives only inanimate objects on a carrier and transmits these objects vertically from one elevation to another.
(D) The following definitions are applicable to conveyors only.
1. Actuator--A device that initiates the action of controls or controllers and is manually operated. The actuator may be a push button, toggle switch, foot pedal, hand lever, hand set timer, or any other device that performs the described function.
2. Carrier
a. A device attached to or hung from trolleys to support the load.
b. The receptacle in which objects are placed for transmittal through a conveying system.
c. The moving part of a vertical or inclined reciprocating conveyor that supports the load.
3. Control(s)--The system governing the starting, stopping, direction of motion, acceleration, speed, retardation, identification, and function of the moving member in a predetermined manner.
4. Controller--An electromechanical device or assembly of devices for starting, stopping, accelerating, or decelerating a drive, or serving to govern in some predetermined manner the power delivered to the drive.
5. Drive--An assembly of the necessary structural, mechanical, and electrical parts that provide the motive power for a conveyer.
6. Emergency Stop--A stop arising from a sudden and unexpected need, and not as a part of the normal operation.
7. Emergency Stop Device--A device that must be actuated in an emergency situation to stop a conveyor.
8. Enclosed--Describes guarding of moving parts in such a manner that physical contact by parts of the body is precluded as long as the guard remains in place. The guarding may make use of hinged, sliding, or removable doors for inspection or lubrication.
9. Guard--A covering or barricade to prevent entry into operating components such as gear, chain, and nip guards; a structure mounted below an overhead mounted conveyor to protect personnel from falling materials.
10. Guarded--Shielded, fenced, enclosed, or otherwise protected by means of suitable enclosure, covers, casing, shields, troughs, railings, or by nature of location so as to reduce foreseeable risk of personal injury.
11. Guarded By Location--Describes moving parts so protected by their remoteness from the floor, platform, walkway, or other working level, or by their location with reference to frame, foundation, or structure as to reduce the foreseeable risk of accidental contact by persons or objects. Remoteness from foreseeable, regular, or frequent presence of public or employed personnel may in reasonable circumstance constitute guarding by location.
12. Nip Point--A point at which a machine element moving in line meets a rotating element in such a manner that it is possible to nip, pinch, squeeze, or entrap a person or objects coming into contact with one of the two members. The same definition holds for the similar point with respect to two rotating parts or two converging parts in linear movement.
13. Operator's Station--Location at which actuators are placed for the purpose of starting, stopping, reversing, or otherwise controlling the conveyor or system of conveyors in the course of normal operation.
14. Overload Device--A mechanical or electrical device designed to disconnect the driven equipment from the driving equipment in event of an overload on the conveyor.
15. Qualified Person--A person who, by profession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience has successfully demonstrated his ability to solve problems relating to the subject matter and work.
16. Rated Capacity--Rated capacity shall mean the capacity at the rated speed, as established by the manufacturer or a qualified person, at which safe and satisfactory service can be expected.
17. Rated Speed--Rated speed shall mean the speed of the conveyor, as established by the manufacturer or a qualified person, at which safe and satisfactory service can be expected.
18. Remote Control--Any system of controls in which the actuator is situated in a remote location.
19. Remote Location--Any location, with respect to the conveyor, from which the presence or position of personnel relative to the conveyor cannot be readily determined from the operator's station.
20. Safety Device--A mechanism or an arrangement placed in use for the specific purposes of preventing an unsafe condition, preventing the continuation of an unsafe condition, warning of an unsafe condition, or limiting or eliminating the unsafe effects of a possible condition.
21. Walkway--An elevated passageway for persons above the surrounding floor or ground level. Included in this definition are catwalks, footwalks, runways, and elevated walkways.
(E) Operation, Material Handling Device. Operation of a material handling device shall mean the loading, unloading and actuation of the control.
(F) Operator, Material Handling Device. The operator of a material handling device shall mean the individual trained in safe operation of the particular device.
Moving Walk. A type of passenger-carrying device on which passengers stand or walk, and in which the passenger-carrying surface remains parallel to its direction of motion and is uninterrupted.
Moving Walks are classified by the following types:
(A) Belt Type. A moving walk with a power driven continuous belt treadway.
(B) Belt Pallet Type. A moving walk with a series of connected and power driven pallets to which a continuous belt treadway is fastened.
(C) Edge-Supported Belt Type. A moving walk with the treadway supported near its edge by a succession of rollers.
(D) Pallet Type. A moving walk with a series of connected and power driven pallets which together constitute the treadway.
(E) Roller-Bed Type. A moving walk with the treadway supported throughout its width by a succession of rollers.
(F) Slider-Bed Type. A moving walk with the treadway sliding upon a supporting surface.
Non-Interference. A feature of an elevator which gives preference to a passenger on the elevator for direction of travel and of the stops, over passengers waiting at the landings.
Operating Device. The car switch, pushbutton, lever, or other manual device used to actuate the control.
Operation. The method of actuating the control.
(A) Automatic Operation. Operation wherein the starting of the elevator car is effected in response to the momentary actuation of operating devices at the landing, or of operating devices in the car identified with the landings, or in response to an automatic starting mechanism, and wherein the car is stopped automatically at the landings.
1. Group Automatic Operation. Automatic operation of two or more nonattendant elevators equipped with power-operated car and hoistway doors. The operation of the cars is coordinated by a supervisory control system, including automatic dispatching means, whereby selected cars at designated dispatching points automatically close their doors and proceed on their trips in a regulated manner. It includes one button in each car for each landing served and up-and-down buttons at each landing (single buttons at terminal landings). The stops set up by the momentary actuation of the car buttons are made automatically in succession as a car reaches the corresponding landings irrespective of its direction of travel or the sequence in which the buttons are actuated. The stops set up by the momentary actuation of the landing buttons may be accomplished by any elevator in the group, and are made automatically by the first available car that approaches the landing in the corresponding direction.
2. Nonselective Collective Automatic Operation. Automatic operation by means of one button in the car for each landing level served and one button at each landing, wherein all stops registered by the momentary actuation of landing or car buttons are made irrespective of the number of buttons actuated or of the sequence in which the buttons are actuated. With this type of operation the car stops at all landings for which buttons have been actuated, making the stops in the order in which the landings are reached after the buttons have been actuated, but irrespective of its direction of travel.
3. Selective Collective Automatic Operation. Automatic operation by means of one button in the car for each landing level served and by up-and-down buttons at the landings, wherein all stops registered by the momentary actuation of the car buttons are made as defined under nonselective collective automatic operation, but wherein the stops registered by the momentary actuation of the landing buttons are made in the order in which the landings are reached in each direction of travel after the buttons have been actuated. With this type of operation, all "up" landing calls are answered when the car is traveling in the up direction and all "down" landing calls are answered when the car is traveling in the down direction.
4. Single Automatic Operation. Automatic operation by means of one button in the car for each landing level served and one button at each landing, so arranged that if any car or landing button has been actuated, the actuation of any other car or landing operating button will have no effect on the operation of the car until the response of the first button has been completed.
(B) Call and Send Operation. Operation in which buttons are provided at the landings both for calling the elevator to that landing or for dispatching the elevator to other landings.
(C) Car-Switch Operation. Operation wherein the movement and direction of travel of the car are directly and solely under the control of the operator by means of a manually operated car switch or of continuous-pressure buttons in the car.
(D Car-Switch Automatic Floor-Stop Operation. Operation in which the stop is initiated by the operator from within the car with a definite reference to the landing at which it is desired to stop, after which the slowing down and stopping of the elevator is effected automatically.
(E) Continuous-Pressure Operation. Operation by means of buttons or switches in the car and at the landings, any one of which may be used to control the movement of the car as long as the button or switch is manually maintained in the actuating position.
(F) Preregister Operation. Operation in which signals to stop are registered in advance by buttons in the car and at the landings. At the proper point in the car travel, the operator in the car is notified by a signal (visual, audible, or otherwise) to initiate the stop, after which the landing stop is automatic.
(G) Signal Operation. Operation by means of single buttons or switches, or both, in the car, and up-or-down direction buttons, or both, at the landings, by which predetermined landing stops may be set up or registered for an elevator or for a group of elevators. The stops set up by momentary actuation of the car buttons are made automatically in succession as the car reaches those landings, irrespective of its direction of travel or the sequence in which the buttons are actuated. The stops set up by the momentary actuation of the up-and-down buttons at the landing are made automatically by the first available car in the group approaching the landing in the corresponding direction, irrespective of the sequence in which the buttons are actuated. With this type of operation, the car can be started only by means of a starting switch or button in the car.
Overhead Structure. All of the structural members, platforms, etc., supporting the elevator machinery, sheaves, and equipment at the top of the hoistway.
Parking Device, Elevator. An electrical or mechanical device, the function of which is to permit the opening from the landing side of the hoistway door at any landing when the car is within the landing zone of that landing. The device may also be used to close the door.
Pit, Elevator. That portion of a hoistway extending from the threshold level of the lowest landing door to the floor at the bottom of the hoistway.
Platform Guard. A smooth metal panel extending below the car seal, which eliminates the opening below the platform when the elevator is above the landing and in the leveling zone.
Rated Load. The load which the elevator, dumbwaiter, escalator, moving walk, or inclined lift is designed and installed to lift or move at the rated speed.
Rated Speed. The speed at which the elevator, dumbwaiter, escalator, moving walk, manlift, or inclined lift is designed to operate under the following conditions:
1. Elevator or Dumbwaiter. The speed in the "up" direction with rated load in the car.
2. Escalator, Moving Walk, or Inclined Lift. The rate of travel of the steps, treadway, or carriage, measured along the angle of inclination, with rated load on the steps or carriage. In the case of a reversible escalator, the rated speed shall be the rate of travel of the steps in the "up" direction, measured along the angle of inclination, with rated load on the steps.
Repairs. The word "repairs" where used herein shall mean only such work as is necessary to maintain present equipment in a safe and serviceable condition and to adjust or replace defective, broken, or worn parts with parts made of equivalent material, strength, and design, and where the replacing part performs the same function as the replaced part.
Restricted Area (Applicable to article 12.1). See under Material Handling Devices.
Rope Equalizer, Suspension. A device installed on an elevator car or counterweight to equalize automatically the tensions in the hoisting wire ropes.
Rope-Fastening Device, Auxiliary. A device attached to the car or counterweight or to the overhead dead-end rope-hitch support which will function automatically to support the car or counterweight in case the regular wire rope fastening fails at the point of connection to the car or counterweight or at the overhead dead-end hitch.
Runby, Bottom Elevator Car. The distance between the car buffer striker plate and the striking surface of the car buffer when the car floor is level with the bottom terminal landing.
Runby, Bottom Elevator Counterweight. The distance between the counterweight buffer striker plate and the striking surface of the counterweight buffer when the car floor is level with the top terminal landing.
Safety, Car or Counterweight. A mechanical device attached to the car frame or to an auxiliary frame, or to the counterweight frame, to stop and hold the car or counterweight in case of predetermined overspeed or free fall, or if the hoisting ropes slacken.
Screw Column. A vertical structural member provided with screw threads which supports the car of a screw column elevator. The screw column may be either in tension or compression.
Seismic Switch. See under Earthquake Protection Devices.
Shaft, Shaftway. See Hoistway.
Shall. The term "shall" where used shall be construed as mandatory.
Should. The term "should" where used shall be construed as advisory.
Slack-Rope Switch. A device which automatically causes the electric power to be removed from the elevator driving-machine motor and brake when the hoisting ropes of a winding-drum machine become slack.
Solid State Device. An element that can control current without moving parts.
Special Access Lifts.
(A) Inclined Stairway Chairlift. a.k.a. "Stairway Elevator." An inclined stairway chairlift is a seat(s) or chair(s) that travels on a stairway.
(B) Gurney Lift. A gurney lift is a hoisting and lowering mechanism, for use by a person(s) in a gurney, stretcher or similar device and an attendant(s) and possibly a support system. It consists of a platform with a minimal enclosure that moves through a fixed course either vertically or on an incline, and is used or fixed in a permanent location. The Division shall determine the specific lifts which are gurney lifts, for the purpose of these orders. This determination shall apply equally to all similar or identical lifts used in a similar manner.
(C) Wheelchair Lift. A wheelchair lift is a hoisting and lowering mechanism for use by a person unable to use stairs. It consists of a platform with a minimal enclosure that moves through a fixed course either vertically or on an incline (which is often a stairway), and is used or fixed in a permanent location. The Division shall determine the specific lifts which are wheelchair lifts, for the purpose of these orders. This determination shall apply equally to all similar or identical lifts used in a similar or identical manner.
1. Inclined Wheelchair Lift. An inclined wheelchair lift is a wheelchair lift designed to operate on an incline which is often a stairway.
2. Vertical Wheelchair Lift. A vertical wheelchair lift is a wheelchair lift designed to operate vertically.
(D) The following definitions are applicable to Special Access Lift only.
1. Runway. For stairway chairlifts and wheelchair lifts, the space in which the car, platform, or seat moves.
2. Side Guard. The panels on the sides of the wheelchair lift platform not used for entrance. They are usually 42 in. (1.067m) high and are a form of car enclosure.
3. Toe Guard. Toe guard refers to the panels extending below the platform. They eliminate all accessible areas under the platform when it is above the lower landing. It may be a telescoping-type device.
Stage Lift. A stage lift is a hoisting and lowering mechanism with a platform that at some elevation is a stage or a part of a stage, such as an orchestra pit. The Division shall determine the specific lifts which are stage lifts, for the purpose of these orders. This determination shall apply equally to all similar or identical lifts used in a similar or identical manner.
Static Switching. Switching of circuits by means of solid state devices.
Stopping Devices, Normal. The automatic device used to actuate the control to slow and stop an elevator or dumbwaiter car at any landing.
Terminal Stopping Device, Emergency. A device which automatically causes the power to be removed from the electric elevator driving machine motor and brake, or from a hydraulic elevator machine, at a predetermined distance from the terminal landing, and independently of the functioning of the normal stopping device, the operating device and normal terminal stopping device, if the normal terminal stopping device does not slow down the car as intended.
Terminal Stopping Device, Final. A device which automatically causes the power to be removed from an electric elevator or dumbwaiter driving machine motor and brake, or from a hydraulic elevator or dumbwaiter machine, independently of the functioning of the normal terminal stopping device, the normal stopping device, the operating device, or any emergency terminal stopping device, after the car has passed a terminal landing.
Terminal Stopping Device, Machine Final. A final terminal stopping device operated directly by the driving machine.
Terminal Stopping Device, Normal. A device or devices used to slow down and stop an elevator or dumbwaiter car automatically at or near a terminal landing independently of the functioning of the normal stopping device or the operating device. The device includes the terminal stopping switch, together with such terminal slow-down switches necessary to stop the car at or near the terminal landing.
Travel or Rise. The vertical distance between the bottom terminal landing and the top terminal landing of an elevator, dumbwaiter, escalator, and inclined lift.
Traveling Cable. A cable made up of electric conductors which provides electrical connection between an elevator or dumbwaiter car and a fixed connection in the hoistway.
Truck-Zoning Device, Elevator. A device which will permit the operator in the car to move a freight elevator within the truck zone with the car door or gate and a hoistway door or gate open.
Truck Zone, Elevator. The limited distance above an elevator landing within which the truck zoning device permits movement of the elevator car.
U-Groove. A shape of groove used on the drive sheave of a double wrap traction machine, approximately a semicircle, with a radius approximately equal to the diameter of the hoist rope.
Undercutting. A process of removing, by sawing or scraping, part of the mica until it is below the surface of the copper of a commutator.
Undercut U-Groove. A modified V-groove which has the lower sides cut in the shape of a U.
Vane. (1) A thin piece of metal attached to a stationary structure in the hoistway to provide the actuating part of a magnetically operated switch assembly mounted on the car. These switches are used to perform several functions.
(2) A device mounted on a car door panel to transmit door operating power to the hoistway door.
V-Groove. One form of traction sheave groove which is contoured in the shape of a straight-sided, flat bottom V.
Vision Panel. A small glass panel located in entrance doors to permit the passengers or attendant to see when the car has reached the landing.
Working Pressure. The pressure measured in the liquid line to the cylinder or plunger of a hydraulic elevator, when lifting the car and its rated load at rated speed, or, with Class C-2 loading when leveling up with maximum static load.
(Title 24, part 7, section 7-3009)
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Amendment of subsection (b) filed 12-22-78; effective thirtieth day thereafter (Register 79, No. 1). For prior history, see Register 75, No. 36; 76, No. 22; 76, No. 48; 77, No. 26; and 78, No. 30.
2. Amendment of subsection (b) filed 9-29-82; effective thirtieth day thereafter (Register 82, No. 40).
3. Amendment filed 5-23-88; operative 6-22-88 (Register 88, No. 22).
4. Change without regulatory effect filed 8-16-89 pursuant to Section 100, Title 1, California Code of Regulations (Register 89, No. 42).
5. Editorial correction of printing errors in subsection (b) (Register 91, No. 42).
6. Amendment of subsection (C) and Reference citation added; filed 7-1-91; operative 7-31-91 (Register 91, No. 43).
Go Back to Article 6 Table of Contents