Skip to Main Content


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 4. Construction Safety Orders
Article 15. Cranes and Derricks in Construction
Return to index
New query

§ 1610.2. Design Standards.


(a) Cranes and derricks used in construction which are manufactured prior to July 7, 2011 shall be designed, constructed and installed in accordance with the applicable standards of General Industry Safety Orders, Section 4884.

(b) Cranes and derricks used in construction which are manufactured on or after July 7, 2011 shall be designed, constructed and installed in accordance with the following applicable standards which are hereby incorporated by reference:

(1) American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME) standards:

(A) ASME B30.2-2005, Overhead and Gantry Cranes (Top Running Bridge, Single or Multiple Girder, Top Running Trolley Hoist), issued Dec. 30, 2005.

(B) B30.3-1996, Construction Tower Cranes (includes Hammerhead Tower Cranes).

(C) B30.4-1996, Portal, Tower and Pedestal.

(D) ASME B30.5-2004, Mobile and Locomotive Cranes, issued Sept. 27, 2004.

(E) B30.6-1995, Derricks.

(F) ASME B30.7-2001, Base-Mounted Drum Hoists, issued Jan. 21, 2002.

(G) B30.8-1982, Floating Cranes and Floating Derricks.

(H) B30.11-1980, Monorails and Underhung Cranes.

(I) B30.13-1977, Controlled Mechanical Storage Cranes.

(J) ASME B30.14-2004, Side Boom Tractors, issued Sept. 20, 2004.

(K) B30.17-1992, Overhead and Gantry Cranes (Top Running Bridge, Single Girder, Underhung Hoist).

(2) American Welding Society (AWS) standards:

(A) AWS D1.1/D1.1M:2002, Structural Welding Code - Steel, 18th ed., ANSI approved Aug. 31, 2001.

(B) ANSI/AWS D14.3-94, Specification for Welding Earthmoving and Construction Equipment, ANSI approved Jun. 11, 1993.

(3) British Standards Institution (BSI) standards:

(A) BS EN 13000:2004, Cranes - Mobile Cranes, published Jan. 4, 2006.

(B) BS EN 14439:2006, Cranes - Safety - Tower Cranes, published Jan. 31, 2007.

(4) International Organization for Standardization (ISO) standards:

(A) ISO 11660-1:2008(E), Cranes - Access, guards and restraint - Part 1: General, 2d ed., Feb. 15, 2008.

(B) ISO 11660-2:1994(E), Cranes - Access, guards and restraints - Part 2: Mobile cranes, 1994.

(C) ISO 11660-3:2008(E), Cranes - Access, guards and restraint - Part 3: Tower cranes, 2d ed., Feb. 15, 2008.

(5) Power Crane and Shovel Association (PCSA) standards:

(A) PCSA Std. No. 1, Mobile Crane and Excavator Standards, 1968.

(B) PCSA Std. No. 2, Mobile Hydraulic Crane Standards, 1968.

(C) PCSA Std. No. 3, Mobile Hydraulic Excavator Standards, 1969.

(6) Society of Automotive Engineers (SAE) standards:

(A) SAE J185 (reaf. May 2003), Access Systems for Off-Road Machines, reaffirmed May 2003.

(B) SAE J987 (rev. Jun. 2003), Lattice Boom Cranes - Method of Test, revised Jun. 2003.

(C) SAE J1063 (rev. Nov. 1993), Cantilevered Boom Crane Structures - Method of Test, revised Nov. 1993.

(c) All electrically powered cranes and derricks shall also comply with applicable CCR Title 8 Electrical Safety Orders.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-7-2011; operative 7-7-2011. Exempt from OAL review pursuant to Labor Code section 142.3(a)(3) (Register 2011, No. 27).


Go BackGo Back to Article 15 Table of Contents