Decompression Tables
1. EXPLANATION. The decompression tables are computed for working chamber pressures from 0 to 14 pounds, and from 14 to 50 pounds per square inch gauge inclusive by 2-pound increments and for exposure times for each pressure extending from 1/2 to over 8 hours inclusive. Decompressions will be conducted by 2 or more stages with a maximum of 4 stages, the latter for a working chamber pressure of 40 pounds per square inch gauge or over.
Stage 1 consists of a reduction in ambient pressure ranging from 10 to a maximum of 16 pounds per square inch, but in no instance will the pressure be reduced below 4 pounds at the end of stage 1. This reduction in pressure in stage 1 will always take place at a rate not greater than 5 pounds per minute.
Further reduction in pressure will take place during stage 2 and subsequent stages as required at a slower rate, but in no event at a rate greater than 1 pound per minute.
Decompression Table No. 1 indicates in the body of the table the total decompression time in minutes for various combinations of working chamber pressure and exposure time.
Decompression Table No. 2 indicates for the same various combinations of working chamber pressure and exposure time the following:
a. The number of stages required;
b. The reduction in pressure and the terminal pressure for each required stage;
c. The time in minutes through which the reduction in pressure is accomplished for each required stage;
d. The pressure reduction rate in minutes per pound for each required stage;
IMPORTANT NOTE: THE PRESSURE REDUCTION IN EACH STAGE IS ACCOMPLISHED AT A UNIFORM RATE. DO NOT INTERPOLATE BETWEEN VALUES SHOWN ON THE TABLES. USE THE NEXT HIGHER VALUE OF WORKING CHAMBER PRESSURE OR EXPOSURE TIME SHOULD THE ACTUAL WORKING CHAMBER PRESSURE OR THE ACTUAL EXPOSURE TIME, RESPECTIVELY, FALL BETWEEN THOSE FOR WHICH CALCULATED VALUES ARE SHOWN IN THE BODY OF THE TABLES.
Examples:
Example No. 1
4 hours working period at 20 pounds gauge
Decompression Table No. 1
20 pounds for 4 hours,
Total Decompression Time........................ 43 minutes
Decompression Table No. 2
Stage 1
Reduce pressure from 20 pounds to 4 pounds at the
uniform rate of 5 pounds per minute.
Elapsed time stage 1: 1 6/5 ............. 3 minutes
Stage 2 (final stage)
Reduce pressure at a uniform rate from 4
pounds to 0 pound gauge over a period of 40 minutes.
Rate--0.10 pounds per minute or 10.00 minutes per
pound
Stage 2 (final) elapsed time.................. 40 minutes
Total Time.................................... 43 minutes
Example No. 2
5-hour working period at 24 pounds gauge
Decompression Table No. 1
24 pounds for 5 hours
Total Decompression Time........................ 117 minutes
Decompression Table No. 2
Stage 1
Reduce pressure from 24 pounds to 8 pounds at
the uniform rate of 5 pounds per minute
Elapsed time stage 1: 1 6/5................ 3 minutes
Stage 2
Reduce pressure at a uniform rate from 8 pounds to
4 pounds over a period of 4 minutes.
Rate, 1 pound per minute
Elapsed time, stage 2......................... 4 minutes
Transfer persons to Special Decompression Chamber
maintaining the 4-pound pressure during the transfer
operation.
Stage 3 (final stage)
In the Special Decompression Chamber, reduce the
pressure at a uniform rate from 4 pounds to 0 pound
gauge over a period of 110 minutes.
Rate, 0.037 pounds per minute or 27.5 minutes per
pound
Stage 3 (final) elapsed time 110 minutes
Total Time...................................... 117 minutes
DECOMPRESSION TABLE NO. 1 -- TOTAL DECOMPRESSION TIME
__________________________________________________________________
Work | Working period hours
pressure|_________________________________________________________
p.s.i.g | | | | | | | | | | | Over
|1/2 | 1 |1 1/2| 2 | 3 | 4 | 5 | 6 | 7 | 8 | 8
________|____|___|_____|____|____|____|____|____|____|____|_______
| | | | | | | | | | |
0 to 12.| 3 | 3| 3 | 3| 3| 3| 3| 3| 3| 3| 3
14......| 6 | 6| 6 | 6| 6| 6| 6| 6| 16| 16| 33
16......| 7 | 7| 7 | 7| 7| 7| 17| 33| 48| 48| 62
18......| 7 | 7| 7 | 8| 11| 17| 48| 63| 63| 73| 87
20......| 7 | 7| 8 | 15| 15| 43| 63| 73| 83| 103| 113
22......| 9 | 9| 16 | 24| 38| 68| 93| 103| 113| 128| 133
24......| 11 | 12| 23 | 27| 52| 92| 117| 122| 127| 137| 151
26......| 13 | 14| 29 | 34| 69| 104| 126| 141| 142| 142| 163
28......| 15 | 23| 31 | 41| 98| 127| 143| 153| 153| 165| 183
30......| 17 | 28| 38 | 62| 105| 143| 165| 168| 178| 188| 204
32......| 19 | 35| 43 | 85| 126| 163| 178| 193| 203| 213| 226
34......| 21 | 39| 58 | 98| 151| 178| 195| 218| 223| 233| 248
36......| 24 | 44| 63 | 113| 170| 198| 223| 233| 243| 253| 273
38......| 28 | 49| 73 | 128| 178| 203| 223| 238| 253| 263| 278
40......| 31 | 49| 84 | 143| 183| 213| 233| 248| 258| 278| 288
42......| 37 | 56| 102 | 144| 189| 215| 245| 260| 263| 268| 293
44......| 43 | 64| 118 | 154| 199| 234| 254| 264| 269| 269| 293
46......| 44 | 74| 139 | 171| 214| 244| 269| 274| 289| 299| 318
48......| 51 | 89| 144 | 189| 229| 269| 299| 309| 319| 319| ...
50......| 58 | 94| 164 | 209| 249| 279| 309| 329| ...| ...| ...
________|____|___|_____|____|____|____|____|____|____|____|_____
DECOMPRESSION TABLE NO. 2
[Do not interpolate, use next higher value
for conditions not computed]
____________________________________________________________________
| |
| | Decompression data
| |___________________________________________________
Working | | | | | |
chamber |Working| |Pressure reduc.| Time |Pressure | Total
pressure|peroid |Stage| p.s.i.g. | in | reduc. | time
p.s.i.g.| hours | No. |_______________| stage | rate |decompress
| | | | |minutes|Min/pound| minutes
| | | From | To | | |
________|_______|_____|_______|_______|_______|_________|___________
| | | | | | |
14......| 1/2 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 1 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 1 1/2 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 2 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 3 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 4 | 1 | 14 | 0 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 5 | 1 | 14 | 4 | 2 | 0.20 | 6
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 6 | 1 | 14 | 4 | 2 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 6
| 7 | 1 | 14 | 4 | 2 | 0.20 | .....
| | 2 | 4 | 0 | 14 | 3.50 | 16
| 8 | 1 | 14 | 4 | 2 | 0.20 | .....
| | 2 | 4 | 0 | 14 | 3.50 | 16
|Over 8 | 1 | 14 | 4 | 2 | 0.20 | .....
| | 2 | 4 | 0 | 30 | 7.50 | 32
16......| 1/2 | 1 | 16 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 | 1 | 16 | 4 | 3 | 0.20 | 7
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 1/2 | 1 | 16 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 2 | 1 | 16 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 3 | 1 | 16 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 4 | 1 | 14 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 5 | 1 | 14 | 4 | 3 | 0.20 | 7
| | 2 | 4 | 0 | 4 | 3.50 | 17
| 6 | 1 | 14 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 30 | 7.50 | 33
| 7 | 1 | 14 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 45 | 11.25 | 48
| 8 | 1 | 14 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 45 | 11.25 | 48
|Over 8 | 1 | 14 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 60 | 15.00 | 63
18......| 1/2 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 1/2 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 2 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 5 | 1.25 | 8
| 3 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 8 | 2.00 | 11
| 4 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 14 | 3.50 | 17
| 5 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 45 | 11.25 | 48
| 6 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 60 | 15.00 | 63
| 7 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 60 | 15.00 | 63
| 8 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 70 | 17.50 | 73
|Over 8 | 1 | 18 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 84 | 21.00 | 87
20......| 1/2 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 4 | 1.00 | 7
| 1 1/2 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 5 | 1.25 | 8
| 2 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 12 | 3.00 | 15
| 3 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 12 | 3.00 | 15
| 4 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 40 | 10.00 | 43
| 5 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 60 | 15.00 | 63
| 6 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 70 | 17.50 | 73
| 7 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 80 | 20.00 | 83
| 8 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 100 | 25.00 | 103
|Over 8 | 1 | 20 | 4 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 110 | 27.50 | 113
22......| 1/2 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 6 | 1.00 | 9
| 1 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 6 | 1.00 | 9
| 1 1/2 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 13 | 2.20 | 16
| 2 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 21 | 3.50 | 24
| 3 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 35 | 5.85 | 38
| 4 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 65 | 10.83 | 68
| 5 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 90 | 15.00 | 93
| 6 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 4 | 0 | 100 | 16.67 | 103
| 7 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 110 | 18.35 | 113
| 8 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 125 | 20.80 | 128
|Over 8 | 1 | 22 | 6 | 3 | 0.20 | .....
| | 2 | 6 | 0 | 130 | 21.70 | 133
24......| 1/2 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 11
| 1 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 5 | 1.25 | 12
| 1 1/2 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 16 | 4.00 | 23
| 2 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 20 | 5.00 | 27
| 3 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 45 | 11.25 | 52
| 4 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 85 | 21.25 | 92
| 5 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 110 | 27.50 | 117
| 6 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 115 | 28.80 | 122
| 7 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 120 | 30.00 | 127
| 8 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 4 | 1.00 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 137
|Over 8 | 1 | 24 | 8 | 3 | 0.20 | .....
| | 2 | 8 | 4 | 8 | 2.00 | .....
| | 3 | 4 | 0 | 140 | 35.00 | 151
26......| 1/2 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 13
| 1 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 5 | 1.25 | 14
| 1 1/2 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 20 | 5.00 | 29
| 2 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 25 | 6.25 | 34
| 3 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 60 | 15.00 | 69
| 4 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 6 | 1.00 | .....
| | 3 | 4 | 0 | 95 | 23.75 | 104
| 5 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 8 | 1.33 | .....
| | 3 | 4 | 0 | 115 | 28.80 | 126
| 6 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 8 | 1.33 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 141
| 7 | 1 | 26 | 10 | 3 | 2.20 | .....
| | 2 | 10 | 4 | 9 | 1.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 142
| 8 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 9 | 1.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 142
|Over 8 | 1 | 26 | 10 | 3 | 0.20 | .....
| | 2 | 10 | 4 | 30 | 5.00 | .....
| | 3 | 4 | 0 | 30 | 32.50 | 163
28......| 1/2 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 8 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 15
| 1 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 8 | 1.00 | .....
| | 3 | 4 | 0 | 12 | 3.00 | 23
| 1 1/2 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 8 | 1.00 | .....
| | 3 | 4 | 0 | 20 | 5.00 | 31
| 2 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 8 | 1.00 | .....
| | 3 | 4 | 0 | 30 | 7.50 | 41
| 3 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 10 | 1.25 | .....
| | 3 | 4 | 0 | 85 | 21.20 | 98
| 4 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 14 | 1.75 | .....
| | 3 | 4 | 0 | 110 | 27.50 | 127
| 5 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 20 | 2.50 | .....
| | 3 | 4 | 0 | 120 | 30.00 | 143
| 6 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 20 | 2.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 153
| 7 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 20 | 2.50 | .....
| | 3 | 4 | 0 | 120 | 32.50 | 153
| 8 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 32 | 4.00 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 165
|Over 8 | 1 | 28 | 12 | 3 | 0.20 | .....
| | 2 | 12 | 4 | 50 | 6.25 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 183
30......| 1/2 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 10 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 17
| 1 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 10 | 1.00 | .....
| | 3 | 4 | 0 | 15 | 3.75 | 28
| 1 1/2 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 10 | 1.00 | .....
| | 3 | 4 | 0 | 25 | 6.25 | 38
| 2 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 14 | 1.40 | .....
| | 3 | 4 | 0 | 45 | 11.25 | 62
| 3 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 17 | 1.70 | .....
| | 3 | 4 | 0 | 85 | 21.20 | 105
| 4 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 30 | 3.00 | .....
| | 3 | 4 | 0 | 110 | 27.50 | 143
| 5 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 35 | 3.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 165
| 6 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 35 | 3.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 168
| 7 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 45 | 4.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 178
| 8 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 55 | 5.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 188
|Over 8 | 1 | 30 | 14 | 3 | 0.20 | .....
| | 2 | 14 | 4 | 71 | 7.10 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 204
32......| 1/2 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 12 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 19
| 1 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 12 | 1.00 | .....
| | 3 | 4 | 0 | 20 | 5.00 | 35
| 1 1/2 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 15 | 1.25 | .....
| | 3 | 4 | 0 | 25 | 6.25 | 43
| 2 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 22 | 1.83 | .....
| | 3 | 4 | 0 | 60 | 15.00 | 85
| 3 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 28 | 2.33 | .....
| | 3 | 4 | 0 | 95 | 23.75 | 126
| 4 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 40 | 3.33 | .....
| | 3 | 4 | 0 | 120 | 30.00 | 163
| 5 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 45 | 3.75 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 178
| 6 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 60 | 5.00 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 193
| 7 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 70 | 5.83 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 203
| 8 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 80 | 6.67 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 213
|Over 8 | 1 | 32 | 16 | 3 | 0.20 | .....
| | 2 | 16 | 4 | 93 | 7.75 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 226
34......| 1/2 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 14 | 1.00 | .....
| | 3 | 4 | 0 | 4 | 1.00 | 21
| 1 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 14 | 1.00 | .....
| | 3 | 4 | 0 | 22 | 5.50 | 39
| 1 1/2 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 25 | 1.80 | .....
| | 3 | 4 | 0 | 30 | 7.50 | 58
| 2 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 35 | 2.50 | .....
| | 3 | 4 | 0 | 60 | 15.00 | 98
| 3 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 43 | 3.10 | .....
| | 3 | 4 | 0 | 105 | 26.25 | 151
| 4 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 55 | 3.93 | .....
| | 3 | 4 | 0 | 120 | 30.00 | 178
| 5 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 62 | 4.43 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 195
| 6 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 85 | 6.07 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 218
| 7 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 90 | 6.43 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 223
| 8 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 100 | 7.15 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 233
|Over 8 | 1 | 34 | 18 | 3 | 0.20 | .....
| | 2 | 18 | 4 | 115 | 8.23 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 248
36......| 1/2 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 16 | 1.00 | .....
| | 3 | 4 | 0 | 5 | 1.25 | 24
| 1 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 16 | 1.00 | .....
| | 3 | 4 | 0 | 25 | 6.25 | 44
| 1 1/2 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 30 | 1.88 | .....
| | 3 | 4 | 0 | 30 | 7.50 | 63
| 2 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 40 | 2.50 | .....
| | 3 | 4 | 0 | 70 | 17.50 | 113
| 3 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 52 | 3.25 | .....
| | 3 | 4 | 0 | 115 | 28.75 | 170
| 4 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 65 | 4.06 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 198
| 5 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 90 | 5.63 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 223
| 6 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 100 | 6.25 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 233
| 7 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 110 | 6.88 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 243
| 8 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 120 | 7.50 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 253
|Over 8 | 1 | 36 | 20 | 3 | 0.20 | .....
| | 2 | 20 | 4 | 140 | 8.75 | .....
| | 3 | 4 | 0 | 130 | 32.50 | 273
38......| 1/2 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 16 | 1.00 | .....
| | 3 | 6 | 0 | 9 | 1.50 | 28
| 1 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 16 | 1.00 | .....
| | 3 | 6 | 0 | 30 | 5.00 | 49
| 1 1/2 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 20 | 1.25 | .....
| | 3 | 6 | 0 | 50 | 8.34 | 73
| 2 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 30 | 1.88 | .....
| | 3 | 6 | 0 | 95 | 15.83 | 128
| 3 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 35 | 2.19 | .....
| | 3 | 6 | 0 | 140 | 23.35 | 178
| 4 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 50 | 3.12 | .....
| | 3 | 6 | 0 | 150 | 25.00 | 203
| 5 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 55 | 3.44 | .....
| | 3 | 6 | 0 | 165 | 27.50 | 223
| 6 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 70 | 4.38 | .....
| | 3 | 6 | 0 | 165 | 27.50 | 238
| 7 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 85 | 5.32 | .....
| | 3 | 6 | 0 | 165 | 27.50 | 253
| 8 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 95 | 5.93 | .....
| | 3 | 6 | 0 | 165 | 27.50 | 263
|Over 8 | 1 | 38 | 22 | 3 | 0.20 | .....
| | 2 | 22 | 6 | 110 | 6.88 | .....
| | 3 | 6 | 0 | 165 | 27.50 | 278
40......| 1/2 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 16 | 1.00 | .....
| | 3 | 8 | 4 | 4 | 1.00 | .....
| | 4 | 4 | 0 | 8 | 2.00 | 31
| 1 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 16 | 1.00 | .....
| | 3 | 8 | 4 | 5 | 1.25 | .....
| | 4 | 4 | 0 | 25 | 6.25 | 49
| 1 1/2 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 16 | 1.00 | .....
| | 3 | 8 | 4 | 20 | 5.00 | .....
| | 4 | 4 | 0 | 45 | 11.25 | 84
| 2 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 25 | 1.56 | .....
| | 3 | 8 | 4 | 20 | 5.00 | .....
| | 4 | 4 | 0 | 95 | 23.75 | 143
| 3 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 30 | 1.88 | .....
| | 3 | 8 | 4 | 30 | 7.50 | .....
| | 4 | 4 | 0 | 120 | 30.00 | 183
| 4 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 45 | 2.81 | .....
| | 3 | 8 | 4 | 35 | 8.75 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 213
| 5 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 47 | 2.94 | .....
| | 3 | 8 | 4 | 53 | 13.25 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 233
| 6 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 55 | 3.44 | .....
| | 3 | 8 | 4 | 60 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 248
| 7 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 65 | 4.06 | .....
| | 3 | 8 | 4 | 60 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 258
| 8 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 75 | 4.70 | .....
| | 3 | 8 | 4 | 60 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 268
|Over 8 | 1 | 40 | 24 | 3 | 0.20 | .....
| | 2 | 24 | 8 | 95 | 5.93 | .....
| | 3 | 8 | 4 | 60 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 288
42......| 1/2 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 6 | 1.00 | .....
| | 4 | 4 | 0 | 12 | 3.00 | 37
| 1 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 12 | 2.00 | .....
| | 4 | 4 | 0 | 25 | 6.25 | 56
| 1 1/2 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 23 | 3.83 | .....
| | 4 | 4 | 0 | 60 | 15.00 | 102
| 2 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 30 | 5.00 | .....
| | 4 | 4 | 0 | 95 | 23.75 | 144
| 3 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 50 | 8.34 | .....
| | 4 | 4 | 0 | 120 | 30.00 | 189
| 4 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 17 | 1.06 | .....
| | 3 | 10 | 4 | 65 | 10.83 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 215
| 5 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 27 | 1.69 | .....
| | 3 | 10 | 4 | 85 | 14.18 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 245
| 6 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 27 | 1.69 | .....
| | 3 | 10 | 4 | 100 | 16.67 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 260
| 7 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 30 | 1.88 | .....
| | 3 | 10 | 4 | 100 | 16.67 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 263
| 8 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 35 | 2.19 | .....
| | 3 | 10 | 4 | 100 | 16.67 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 268
|Over 8 | 1 | 42 | 26 | 3 | 0.20 | .....
| | 2 | 26 | 10 | 60 | 3.75 | .....
| | 3 | 10 | 4 | 100 | 16.67 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 293
44......| 1/2 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 8 | 1.00 | .....
| | 4 | 4 | 0 | 16 | 4.00 | 43
| 1 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 20 | 2.50 | .....
| | 4 | 4 | 0 | 25 | 6.25 | 64
| 1 1/2 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 27 | 3.38 | .....
| | 4 | 4 | 0 | 72 | 18.00 | 118
| 2 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 40 | 5.00 | .....
| | 4 | 4 | 0 | 95 | 23.75 | 154
| 3 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 60 | 7.50 | .....
| | 4 | 4 | 0 | 120 | 30.00 | 199
| 4 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 85 | 10.62 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 234
| 5 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 105 | 13.13 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 254
| 6 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 115 | 14.38 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 264
| 7 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 120 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 269
| 8 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 16 | 1.00 | .....
| | 3 | 12 | 4 | 120 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 269
|Over 8 | 1 | 44 | 28 | 3 | 0.20 | .....
| | 2 | 28 | 12 | 40 | 2.50 | .....
| | 3 | 12 | 4 | 120 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 293
46......| 1/2 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 10 | 1.00 | .....
| | 4 | 4 | 0 | 15 | 3.75 | 44
| 1 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 25 | 2.50 | .....
| | 4 | 4 | 0 | 30 | 7.50 | 74
| 1 1/2 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 35 | 3.50 | .....
| | 4 | 4 | 0 | 85 | 21.20 | 139
| 2 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 47 | 4.70 | .....
| | 4 | 4 | 0 | 105 | 26.25 | 171
| 3 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 65 | 6.50 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 214
| 4 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 95 | 9.50 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 244
| 5 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 120 | 12.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 269
| 6 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 125 | 12.50 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 274
| 7 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 34 | 14 | 16 | 1.00 | .....
| | 3 | 10 | 4 | 140 | 14.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 289
| 8 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 16 | 1.00 | .....
| | 3 | 14 | 4 | 150 | 15.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 299
|Over 8 | 1 | 46 | 30 | 3 | 0.20 | .....
| | 2 | 30 | 14 | 25 | 1.56 | .....
| | 3 | 14 | 4 | 160 | 16.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 318
48......| 1/2 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 12 | 1.00 | .....
| | 4 | 4 | 0 | 20 | 5.00 | 51
| 1 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 35 | 2.92 | .....
| | 4 | 4 | 0 | 35 | 8.75 | 89
| 1 1/2 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 45 | 3.75 | .....
| | 4 | 4 | 0 | 80 | 20.00 | 144
| 2 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 60 | 5.00 | .....
| | 4 | 4 | 0 | 110 | 27.50 | 189
| 3 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 90 | 7.50 | .....
| | 4 | 4 | 0 | 120 | 30.00 | 229
| 4 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 120 | 10.00 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 269
| 5 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 140 | 11.67 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 209
| 6 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 160 | 13.33 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 309
| 7 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 170 | 14.17 | .....
| | 4 | 4 | 0 | 130 | 32.50 | .....
| 8 | 1 | 48 | 32 | 3 | 0.20 | .....
| | 2 | 32 | 16 | 16 | 1.00 | .....
| | 3 | 16 | 4 | 170 | 14.17 | .....
| | 4 | 4 | 0 | 130 | 32.50 | .....
50......| 1/2 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 14 | 1.00 | .....
| | 4 | 4 | 0 | 25 | 6.25 | 58
| 1 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 40 | 2.86 | .....
| | 4 | 4 | 0 | 35 | 8.75 | 94
| 1 1/2 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 55 | 3.93 | .....
| | 4 | 4 | 0 | 90 | 22.50 | 164
| 2 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 70 | 5.00 | .....
| | 4 | 4 | 0 | 120 | 30.00 | 209
| 3 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 100 | 7.15 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 249
| 4 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 130 | 8.58 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 279
| 5 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 160 | 11.42 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 309
| 6 | 1 | 50 | 34 | 3 | 0.20 | .....
| | 2 | 34 | 18 | 16 | 1.00 | .....
| | 3 | 18 | 4 | 180 | 12.85 | .....
| | 4 | 4 | 0 | 130 | 32.50 | 329
________|_______|_____|_______|_______|_______|_________|__________
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Amendment of Appendix A filed 8-7-85; effective thirtieth day thereafter (Register 85, No. 32).