This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html.


Subchapter 13. Logging and Sawmill Safety Orders
Article 15. Sawmills

Return to index
New query

§6356. Circular Saw Crack.

Circular saws shall be inspected for cracks each time the teeth are filed or set. Any circular saw found to have developed a crack equal to the following table shall be repaired or replaced.


Length of Crack Saw                         Diameter 
1/2-inch................................... 12 inches 
1-inch..................................... 24 inches 
1 1/2-inch................................. 36 inches 
2-inches................................... 48 inches 
2 1/2 inches............................... 60 inches 
3 inches.............................. Over 60 inches 

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. Amendment filed 2-6-85; effective thirtieth day thereafter (Register 85, No. 6).

Go BackGo Back to Article 15 Table of Contents