This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 20. Flammable Liquids, Gases and Vapors
Article 137. Spray Coating Operations
Return to index
New query

§5459. Automobile Undercoating in Garages.


Undercoating spray operations shall conform to all requirements of this Article pertaining to spray finishing operations.

EXCEPTION: Automobile undercoating operations in garages, conducted in areas having adequate natural or mechanical ventilation, are exempt from the requirements pertaining to spray coating operations, when undercoating materials not more hazardous than kerosene (as classified by Underwriters Laboratories in respect to fire hazard rating 30-40) are used, or undercoating materials using only solvents having a flash point in excess of 100o F(37.8o C) are used, and no open flames or other sources of ignition are within 20 feet while such operations are conducted.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. Amendment filed 12-5-86; effective thirtieth day thereafter (Register 86, No. 51).