| Return to index New query |
(a) Bumpers shall be provided at each end of the trolley travel to prevent trolleys leaving the rails. If the bumpers engage the tread of the wheels, they shall be of a height at least equal to the radius of the wheel. Trolley bumpers shall be capable of stopping the trolley at an average rate of deceleration not exceeding 4.7 feet per second per second when traveling in either direction at 1/3 of the rated load speed. Bumpers shall be designed and installed to minimize parts falling from the trolley in case of breakage.
(b) If there is more than one trolley on the same bridge girder, buffers or other cushioning devices shall be placed between the trolleys. Buffers shall be designed and installed to minimize parts falling from the trolley in case of breakage.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code
HISTORY
1. Amendment filed 2-13-75; effective thirtieth day thereafter (Register 75, No. 7).
2. New NOTE filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).
Go Back to Article 92 Table of Contents