Skip to Main Content


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 13. Cranes and Other Hoisting Equipment
Article 92. Cranes (Except Boom-Type Mobile Cranes)
Return to index
New query

§4895. Illumination.


Sufficient light shall be provided in the cab to enable the operator to see clearly enough to perform the work.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).

Go BackGo Back to Article 91 Table of Contents