This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 4. General Mobile Equipment and Auxiliaries
Article 23. Mobile Ladder Stands and Scaffolds (Towers)
Return to index
New query

ยง3625. Mobile Tube and Coupler Scaffolds.


(a) Units shall be designed to comply with the applicable requirements of Section 3622.

(b) The material used for the couplers shall be of a structural type, such as a drop-forged steel, malleable iron, or structural grade aluminum. The use of gray cast iron is prohibited.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.