This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts

Return to index
New query


§3093.6. Horizontal Car Clearances [Rule 500.6].



(a) There shall be a clearance of not less than 3/4 in. (19 mm) between the car and the hoistway enclosure, and between the car and its counterweight.
(b) The clearance between the car platform and the landing sill shall be not less than 1/2 in. (13 mm) nor more than 1 1/2 in. (38 mm).
(Title 24, Part 7, Section 7-3093.6)
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).
2. Editorial correction of subsection (a) (Register 95, No. 34).
3. Editorial correction of subsection (b) (Register 97, No. 6).
4. Amendment of section heading and section filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).