This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts
Return to index
New query

§3093.45. Emergency Devices.


(a) A telephone, which is connected to a central telephone exchange, shall be installed in the car and an emergency signalling device, operable from inside the car and audible outside the hoistway, shall be provided.

(b) All machines shall be provided with a means to lower the car in case of power failure. The device shall be painted bright red or orange and shall have suitable instructions for use and warnings about use affixed to the operating means.