Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts
§3093.36. Operation of the Stopping Devices.
(a) The final terminal stopping device shall act to prevent movement of the car
in both directions of travel. The normal and final terminal stopping devices shall
not control the same switches on the controller unless two or more separate and
independent switches are provided, two of which shall be closed to complete the
motor and brake circuit in each direction of travel.
(b) The switches required in subsection 3093.36(a) shall be positively opened
mechanically as required by 3039(a).
(Title 24, Part 7, Section 7-3093.36)
NOTE
Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor
Code.
HISTORY
1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86,
No. 36).
2. Amendment of section heading filed 8-29-2001; operative 9-28-2001 (Register
2001, No. 35).