Skip to Main Content


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts
Return to index
New query

§3093.16. Operation of Safeties.


The car safety shall be of the inertia or other approved type operated by the breakage of the suspension means or by the action of a speed governor. If it is a speed governor type, the governor shall operate the safety at a maximum speed of 75 fpm (0.38 m/s). On the breakage of the suspension means, the safety shall operate without delay and independent of the speed governor action.

(Title 24, Part 7, Section 7-3093.16)

NOTE

Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).

2. Amendment of section heading and section filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).

Go BackGo Back to Article 15 Table of Contents