This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 13. Cranes and Other Hoisting Equipment
Article 101. Slings

Return to index
New query


Table S-1a Minimum Allowable Chain Size At Any Point of Link


Chain size (Inches)
Minimum allowable chain size (Inches)
¼
13/64
⅜
19/64
½
25/64
⅝
31/64
¾
19/32
⅞
45/64
1
13/16
1 ⅛
29/32
1 ¼
1
1 ⅜
1 3/32
1 ½
1 3/16
1 ¾
1 13/32