| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
Hydraulic relief valves shall have pressure settings of sufficient magnitude to provide the capabilities of operations under 110% of rated loading conditions. Relief valve settings shall be specified and no change in relief valve setting shall be made without the consent of the certified agent. Gauge ports shall be provided in each hydraulic circuit for checking certified agent's specified pressure settings.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).
Go Back to Article 94 Table of Contents