Subchapter 7. General Industry Safety Orders
Group 8. Points of Operation and Other Hazardous Parts of Machinery
Article 69. Food and Tobacco Machinery

New query

§4545. Dividers.

(a) Guards at the front of a divider shall be so arranged that the weight of the dough can be adjusted without removing the guard.

(b) The back of the divider shall have a complete cover to enclose all of the moving parts or each individual part shall be enclosed or guarded. The rear cover shall be provided with an interlock so arranged that the machine cannot operate when this cover is open.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. Amendment filed 5-1-86; effective thirtieth day thereafter (Register 86, No. 19).

Go BackGo Back to Article 69 Table of Contents