| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) A guard or feeding device shall be provided which will allow feeding of the material without permitting the fingers of the operator to be caught in the nip point(s). This shall be accomplished by:
(1) Provision of a lever, rod or treadle allowing the operator to immediately stop the rolls at the feed point, or
(2) An automatic device which will stop the rolls when the fingers approach the nip point(s).
NOTE: Use of a "Doctor Feed" is acceptable.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 9-15-86; effective thirtieth day thereafter (Register 86, No. 38).