| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) The infeed to the die shall be guarded to prohibit the entry of the operator's hand.
(b) Where hinged or moveable, the guard shall be interlocked to disconnect the power from the prime mover when the guard is in the open position.
(c) A minimum 4-inch clearance shall be provided between the end of the slat and the guide bar.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 9-15-86; effective thirtieth day thereafter (Register 86, No. 38).