| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
In addition to the requirements of Section 3337:
(a) Bridge or dock plates shall be furnished and used to bridge the area between a dock and truck or railcar.
(b) The sides of bridge or dock plates shall have an upturn or lip of at least 4 inches extending between the edge of the loading dock and edge of car or truck floor or other devices whenever the span exceeds 18 inches to prevent wheeled equipment from running off the sides.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Repealer and new section filed 9-15-86; effective thirtieth day thereafter (Register 86, No. 38).