| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) Every plunger on hot chamber machines shall be equipped with a control interlocked with the die which will prevent the operation of the plunger prior to the closing of the die.
(b) Every plunger on cold chamber machines shall be equipped with a control interlocked with the die which will prevent the operation of the plunger unless the die is completely open or completely closed.
(c) For the removal of a stuck plug a cold chamber machine shall be equipped with two-hand controls, which operate the plunger only, and require concurrent use of both hands.