| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) Machines using full revolution clutches shall incorporate a single-stroke control.
EXCEPTION: Automatically fed machines with the point of operation completely protected by a fixed barrier guard.
(b) If the single-stroke control is dependent upon spring action, the spring(s) shall be of the compression-type, operating on a rod or guided within a hole or tube, and designed to prevent interleaving of the spring coils in event of breakage.
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. Repealer of subsections (c) and (d) filed 7-17-75; effective thirtieth day thereafter (Register 75, No. 29).
2. Amendment filed 10-31-85; effective thirtieth day thereafter (Register 85, No. 44).