§1678. Extension Ladders.

(a) Extension ladders shall not exceed 44 feet in length when extended to the limit permitted by the following lap schedule.

(b) Extension ladders shall not be fully extended but shall have the following minimum laps:

(1) Two-Section Ladders.

3 feet for ladders with working length up to 33 feet.

4 feet for ladders with working length 33 to 44 feet.

(2) Three-Section Ladders.

4 feet for each section.