| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) A berm, bumper block, safety hook or similar means, shall be provided to prevent overtravel and overturning of haulage equipment at dumping locations.
(b) Dump track areas shall be maintained reasonably level and properly ballasted or the ties planked over to prevent employees from tripping.
(c) Standard walkways with railings in accordance with Section 1620 of the Construction Safety Orders shall be provided on elevated trestles and at all dump locations.
NOTE: Authority cited: Sections 142.3 and 7997, Labor Code. Reference: Sections 142.3 and 7997, Labor Code.
HISTORY
1. Amendment of section heading, subsections (a)-(c), repealer of subsection (d) and new Note filed 3-5-96; operative 4-4-96 (Register 96, No. 10).