Subchapter 7. General Industry Safety Orders
Group 4. General Mobile Equipment and Auxiliaries
Article 23. Mobile Ladder Stands and Scaffolds (Towers)

New query

§3625. Mobile Tube and Coupler Scaffolds.

(a) Units shall be designed to comply with the applicable requirements of Section 3622.

(b) The material used for the couplers shall be of a structural type, such as a drop-forged steel, malleable iron, or structural grade aluminum. The use of gray cast iron is prohibited.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New NOTE filed 10-12-84 (Register 84, No. 41).