§3093.36. Operation of the Stopping Devices.

(a) The final terminal stopping device shall act to prevent movement of the car in both directions of travel. The normal and final terminal stopping devices shall not control the same switches on the controller unless two or more separate and independent switches are provided, two of which shall be closed to complete the motor and brake circuit in each direction of travel.

(b) The switches required in subsection 3093.36(a) shall be positively opened mechanically as required by 3039(a).

(Title 24, Part 7, Section 7-3093.36)

NOTE

Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).