§3093.27. Factor of Safety for Overhead Beams and Supports.

The factor of safety for overhead beams and supports based on ultimate strength of material shall not be less than 5 for steel, and 6 for timber and reinforced concrete.

(Title 24, Part 7, Section 7-3093.27)