Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts

New query

§3093.26. Fastening of Driving Machines and Sheaves to Underside of Overhead Beams.

(a) Overhead driving machines or sheaves shall not be fastened to the underside of the supporting beams.

Exception to subsection 3093.26(a): Idlers or deflecting sheaves including the guards and frames.

(b) Cast iron in tension shall not be used for supporting idler and deflections sheaves where they are hung beneath the beams.

(Title 24, Part 7, Section 7-3093.26)

NOTE

Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).

2. Amendment of section heading filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).

Go BackGo Back to Article 15 Table of Contents