Subchapter 6. Elevator Safety Orders
Article 15. Special Access Lifts

New query

§3093.19. Location of Speed Governor.

Where a speed governor is used, it shall be located where it is readily accessible from outside the hoistway and it cannot be struck by any moving object in normal operation or under conditions of overtravel and where there is sufficient space for full movement of the governor parts.

(Title 24, Part 7, Section 7-3093.19)

NOTE

Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

HISTORY

1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).

2. Amendment of section heading filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).

Go BackGo Back to Article 15 Table of Contents

The above information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov.