§3087.4. Controls.

(a) Controls shall be remotely installed so as to be inaccessible from the platform or carrier. [6.6.1 and 6.21.2(e)]

(b) Control stations shall be provided for each landing or located near the access point to the platform or carrier.

(c) The area around the starting and stopping devices shall be kept free of obstruction to permit ready access.

(1) Whenever a solid access door is used, audible or visible means shall be provided at each landing to indicate the platform or carrier arrival.

(2) The area around the control stations shall be kept free of obstruction to permit ready access. [5.12(b)]

(Title 24, Part 7, Section 7-3087.4)

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code; and Section 18943, Health and Safety Code.