| New query |
(a) A car door or gate shall be provided at each entrance to the car which, when closed, shall guard the opening to its full height. Car doors may be of solid or openwork construction which will reject a ball 1 in. (25 mm) in diameter. Collapsible car gates shall comply with subsection 3034(e)(5).
(b) A car door or gate contact meeting the requirements of subsection 3034(d)(2) shall be provided.
(Title 24, Part 7, Section 7-3085.16)
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
Go Back to Article 12.3 Table of Contents
| The above information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. |