This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html.

Subchapter 4. Construction Safety Orders
Article 14. Construction Hoists

Return to index
New query

§1605.15. Protection of Operator.

(a) See Article 4, Construction Safety Orders for protection of operator from dust and airborne material.

(b) The operator station of a hoisting machine shall be provided with overhead protection equivalent to tight planking not less than 2 inches thick. The support for the overhead protection shall be of equal strength.

(c) The area occupied by the hoisting machine and its operator shall be protected from the elements and shall be heated in cold weather.

(d) No open-flame heaters shall be allowed inside any operator's enclosure. All other types shall be properly vented.

(e) Heating systems using liquefied petroleum gases shall be installed in compliance with the Unfired Pressure Vessel Safety Orders.

Go BackGo Back to Article 14 Table of Contents