JACKING EQUIPMENT
Lift-slab operations CSO, 1722.1
Vertical Slip Form operations CSO, 1719
JACKS GISO, 3562
Access Restrictions, Adjacent to Lifting Operation GISO, 3562(e)
Antifreeze / Hydraulic Fluid GISO, 3562(c)
Blocking Requirements GISO, 3562(d)
Cleaning / Lubricating GISO, 3562(f)
Design / Maximum Safe Extension GISO, 3562(b)
Foundation /Support, for GISO, 3562(d)
Loading Limit Marked GISO, 3562(a)
Lubricating / Cleaning GISO, 3562(f)
Rated Load Capacity, Marked GISO, 3562(a)
JACKS, Roof Jacks CSO, 1724(a)
JACK SCAFFOLDS, Pump Jack Scaffolds CSO, 1655
JACOB'S LADDER (Chain or Wire Rope Ladder)
Construction Operations per CSO CSO, 1603(h) & (i)
Definition In CSO CSO, 1504(a)
Petroleum Refineries, Transportation & Handling
Approval of PSO-R,T&H, 6799.1(b)
Definition In PSO, R,T&H PSO-R,T&H, 6755
Inspection & Load testing of, In PSO, R,T&H PSO-R,T&H, 6799.1(c)
Use of Jacob's Ladder PSO-R,T&H, 6799.1(e)
Use Plan PSO-R,T&H, 6799.1(d)
Tunneling Operations per TSO, Access in Shafts & Inclines TSO, 8494(a)(1)
J-BOX, Covers ESO-LV, 2340.23
JEWELRY, WATCHES, RINGS, Wearing around Machinery, Prohibition GISO, 3384, Note 2
JOB BUILD
Ladders CSO, 1676
Impalement Protective Covers, Rebar CSO, 1712(d)
JOB ROTATION, Ergonomic Standard
Control of Exposures, RMI Prevention Program Requirements GISO, 5110(b)(2)
JOBSITE VEHICLES CSO, 1597
Brakes, Lights, Operable CSO, 1597(c)
Brakes, Maintained, Operable CSO, 1597(a)
Diesel Engine Exhaust Retrofits per CSO, 1591(m) CSO, 1597(l)
Access of Vehicle not Obstructed CSO, 1591(m)(2)
Engine Performance CSO, 1591(m)(1)
Exhaust Retrofit, Definition CSO, 1504(a)
Installation of Exhaust Retrofit CSO, 1591(m)
Fire Hazard, Effectively Shielded CSO, 1591(m)(3)
Hot Surfaces of Exhaust System, Operator Shielding from CSO, 1591(m)(4)
Obstruction of Operator's View CSO, 1591(m)(5)
Exhaust Stack Requirements CSO, 1591(m)(6)
Maintenance of Exhaust Retrofit CSO, 1591(m)
Visibility Testing Applied to Exhaust Retrofit CSO, 1591, Appx A
Fenders, Mud Flaps CSO, 1597(i)
Inspection at beginning of shift CSO, 1597
Lights, Headlights, Taillights, Operable CSO, 1597(b)
Mud Flaps CSO, 1597(i)
Safety Check, Vehicle CSO, 1597(j)
Seatbelts, Installed CSO, 1597(g)
Use of Seatbelts CSO, 1597(h)
Seats, Adequate number, Secured CSO, 1597(f)
Temporary Covers in Roadways, Secured CSO, 1597(k)
Tools & material, Secured CSO, 1597(e)
Traffic Control CSO, 1598
Flaggers CSO, 1599
Employees exposed to Vehicle Traffic at Excavations CSO, 1541(d)
High Visibility Safety Apparel, Flaggers, warning garments CSO, 1599(d)
High Visibility Safety Apparel, Flaggers, during hours of darkness CSO, 1599(e)
High Visibility Safety Apparel, Flaggers, proper type CSO, 1599(f)
Number of Flaggers CSO, 1599(a)
Traffic Control & Barricades, Public Streets & Highways CSO, 1598
Transport Employees CSO, 1597(f)
Vehicles Safety Check CSO, 1597(j)
Windshields / Wipers / Defogger / Defroster CSO, 1597(d)
JOB TRAINING See TRAINING
JOINTERS, Woodworking GISO, 4311
JOINT POWER & TELE-COM MAN HOLES TelSO, 8616(d)
First Aid Training TelSO, 8616(b)
JOISTS
Structural steel erection, CSO, 1710
Bridging terminus points, illustrations CSO, 1710, Appx A
Double connections, illustrations CSO, 1710, Appx B
JUMBOS, Use in Tunneling operations, per TSO TSO, 8450
JUMPERS, Electrical Equipment Bonding ESO-LV, 2395.79
Attachment ESO-LV, 2395.79(b)
Installation ESO-LV, 2395.79(c)
Material ESO-LV, 2395.79(a)
JUMP SAWS, Woodworking GISO, 4306
Guarding and Point of Operation Guarding GISO, 4306(b), (e)
JUNCTION BOX COVERS ESO-LV, 2473.2(a)
Covers Required, High Voltage ESO-HV, 2745.2
JUNCTION BOXES, High Voltage ESO-HV, Article 8
Conductors Entering Boxes, Cabinets or Fittings ESO-HV, 2754.1
Construction & installation Requirements ESO-HV, 2753
Covers & Canopies ESO-HV, 2754.2
Size of Pull Boxes & Raceway Entrance Locations ESO-HV, 2752