W |
|
|
|
|
|
List of Acronyms |
WALK-IN
COOLERS / FREEZERS, Design Requirements |
|
|
GISO, §3249 |
|
Door Operable on Both Sides, Food Service |
|
|
GISO, §4536 |
WALKING BEAMS, Access to |
|
|
|
|
PSO-D&P, §6632 |
WALKING
SURFACE, |
|
|
|
|
|
|
|
Depressions, Debris, Obstructions, Prohibited |
|
|
GISO, §3273(b) |
|
Glazed Surfaces used as |
|
|
|
|
GISO, §3212(f) |
|
Obstructions, Oil & Grease, Projections,
Water, Prohibited |
|
GISO, §3273(a) |
|
Pallets used as |
|
|
|
|
GISO, §3338 |
|
Sky Lights used as |
|
|
|
|
GISO, §3212(f) |
WALKWAYS |
|
|
|
|
|
GISO, §3272 |
|
Construction Sites, Subject to CSO |
|
|
|
CSO, §1603 |
|
Dangerous Obstructions Prohibited |
|
|
|
GISO, §3273(b) |
|
Mine Safety Orders |
|
|
|
|
MSO, §7046 |
|
Obstructions Prohibited |
|
|
|
|
GISO, §3273(b) |
|
Oil & Gas Refinery, Transportation &
Handling Operations |
|
|
|
|
Access to Stationary Tanks & Reservoirs |
|
PSO-R,T&H, §6803(e) |
|
Oil & Gas Well Operations |
|
|
|
|
|
|
Catwalks at Wells |
|
|
|
PSO-D&P, §6572 |
|
|
Aboveground Tanks, & Containment |
|
|
PSO-D&P, §6548(b)(3) |
|
|
Access Runways, Pipe & Sucker Rod
Platforms |
|
PSO-D&P, §6594 |
|
|
Tanks & Reservoirs |
|
|
|
PSO-D&P, §6546(d) |
|
Permanent |
|
|
|
|
|
GISO, §3273(a) |
|
Traffic |
|
|
|
|
|
GISO, §3272(e)-(f) |
|
Tunnel Safety Orders |
|
|
|
|
TSO, §8411 |
|
Width of |
|
|
|
|
|
GISO, §3272(b) |
WALL OPENINGS, Guarding of |
|
|
|
|
GISO, §3211 |
|
Guardrails |
|
|
|
|
CSO, §1632(k) |
WALL OPENINGS, At Jobsites subject to CSO, Guarding of |
|
|
CSO, §1632 |
|
Chute opening |
|
|
|
|
CSO, §1632 (l) |
|
Covers Specifications |
|
|
|
|
CSO, §1632(b)(3) |
|
Platforms outside wall openings |
|
|
|
CSO, §1632 (k) |
|
Railing & toeboard Specifications |
|
|
|
CSO, §1632(b)(2) |
|
Wall opening protection requirements |
|
|
CSO, §1632 (m) |
|
Wall openings, specified |
|
|
|
|
CSO, §1632 (j) |
WALLS, Retaining walls, Drainage requirements |
|
|
|
PSO-D&P, §6548 |
WAREHOUSES, Working |
|
|
|
|
GISO, §3241.1 |
|
Life Loads |
|
|
|
|
|
GISO, §3241 |
|
Loading |
|
|
|
|
See LOADING |
|
|
Bulk, Flammable / Combustible Liquids |
|
|
GISO, Article 147 |
|
|
Application & Scope |
|
|
|
GISO, §5614 |
|
|
Drainage & Waste Disposal |
|
|
GISO, §5623 |
|
|
Electrical Equipment |
|
|
|
GISO, §5621 |
|
|
Electrical Equipment Classified Areas |
|
|
GISO, §5621, Table FL-19 |
|
|
Fire Control |
|
|
|
|
GISO, §5624 |
|
|
Sources of Ignition |
|
|
|
GISO, §5622 |
|
|
Waste Disposal |
|
|
|
GISO, §5623 |
|
|
Wharves |
|
|
|
|
GISO, §5620 |
WARFARIN, Airborne Contaminant, Exposure limit |
|
|
GISO, §5155, & Appx A |
|
Listed, Permissible Exposure Limits |
|
|
|
GISO, §5155, Table AC-1 |
WARNINGS |
|
|
|
|
|
|
”
” |
|
|
|
|
See also WARNING SIGNS and under SIGNALS |
|
Back-up Alarm, Haulage vehicles backing |
|
|
CSO, §1592 |
|
Cotton gins, warning devices |
|
|
|
GISO, §4644 |
|
Cranes warning devices |
|
|
|
|
GISO, §4889 |
|
|
Boom-type mobile cranes |
|
|
GISO, §4936 |
|
Excavation mobile Equipment, Warning
System |
|
|
CSO, §1541(f) |
|
Forklift |
|
|
|
|
|
GISO, §3661(c ) |
|
Hoists & Hoisting warning devices |
|
|
|
GISO, §4976 |
|
Logging, Before felling trees |
|
|
|
LSSO, §6280 |
|
of Obstruction |
|
|
|
|
GISO, §3273(c) |
|
Railroad Locomotives |
|
|
|
|
GISO, §3734 |
|
Trucks |
|
|
|
|
|
GISO, §3706 |
|
|
Haulage & Earthmoving |
|
|
CSO, §1592 |
WARNING SIGNS |
|
|
|
|
|
|
|
Acrylonitrile |
|
|
|
|
GISO, §5213 |
|
Actinolite, Non-Asbestiform |
|
|
|
GISO, §5208.1(h) |
|
Agricultural Equipment |
|
|
|
|
|
|
|
PTO & Power Transition Components |
|
GISO, §3440(c)(3) |
|
Anhydrous ammonia tanks |
|
|
|
UFPV, §502 |
|
Anthophylite, Non-Asbestiform |
|
|
|
GISO, §5208.1(h) |
|
Arsenic, Inorganic, Warning Signs & Labels |
|
|
GISO, §5214(l) |
|
Asbestos Warning signs near regulated
areas |
|
|
|
|
|
Construction Operations |
|
|
CSO, §1529(k)(7) |
|
|
General industry Requirements |
|
|
GISO, §5208(j)(3) |
|
|
Shipyard Operations |
|
|
|
SSO, §8358(k)(7) |
|
Automatic Starting Machines |
|
|
|
GISO, §3320 |
|
Avalanche Blasting, Misfired Explosives Warning signs |
|
GISO, §5358(j) |
|
Benzene |
|
|
|
|
|
GISO, §5218(j)(1) |
|
Cadmium |
|
|
|
|
|
|
|
|
Construction Operations |
|
|
CSO, §1532(m)(2) |
|
|
General industry Requirements |
|
|
GISO, §5207(m)(2) |
|
Carcinogens |
|
|
|
|
GISO, §5209(e)(1) |
|
Compressed natural gas tanks and cylinders |
|
|
UFPV, §542 |
|
Cotton gins |
|
|
|
|
GISO, §3644 |
|
Cranes, danger of high-voltage overhead lines |
|
|
ESO-HV, §2947 |
|
Derricks, danger of high-voltage overhead lines |
|
|
ESO-HV, §2947 |
|
Drilling rigs, danger of high-voltage overhead
lines |
|
ESO-HV, §2947 |
|
Enclosure Containing Exposed Energized Parts,
Access Doors & Gates |
ESO-HV, §2811 |
|
Equipment, Mobile and portable |
|
|
|
ESO-HV, §2908 |
|
Ethylene Dibromide |
|
|
|
|
GISO, §5219(k) |
|
Ethylene oxide |
|
|
|
|
GISO, §5220(j)(1) |
|
Explosives |
|
|
|
|
|
|
|
|
Avalanche Blasting, Warning signs |
|
|
GISO, §5358(j) |
|
|
Electric Blasting & Road Warning Signs |
|
GISO, §5306(b) |
|
|
Placards |
|
|
|
|
GISO, §5270 |
|
|
Transporting, per GISO |
|
|
|
GISO, §5263 |
|
|
Underground Storage |
|
|
|
GISO, §5258(e) |
|
Formaldehyde |
|
|
|
|
GISO, §5217 |
|
Fumigation |
|
|
|
|
|
|
|
|
Vaults, Chambers, used to Fumigate Products or
Objects |
GISO, §5222(b) |
|
|
Buildings, or Rooms, Fumigation of |
|
|
GISO, §5223(a)(2) |
|
Haulage Vehicles, Backing Up |
|
|
|
CSO, §1592 |
|
Blood Borne Pathogens |
|
|
|
|
GISO, §5193(g)(1) |
|
Hazardous substances warning to employees |
|
|
GISO, §5194(f) |
|
Hazardous substances, Transportation |
|
|
GISO, §5194.1 |
|
Hay loaders, danger of high-voltage overhead
lines |
|
ESO-HV, §2947 |
|
High Voltage Lines |
|
|
|
|
ESO-HV, §2947 |
|
Laser, Warning signs |
|
|
|
|
|
|
|
Construction Operations |
|
|
|
CSO, §1801(d) |
|
|
Tunneling Operations |
|
|
|
TSO, §8416(b) |
|
Lead |
|
|
|
|
|
GISO, §5198(m)(2) |
|
Liquefied natural gas tanks and cylinders |
|
|
UFPV, §542 |
|
Logging, Before felling trees |
|
|
|
LSSO, §6280 |
|
Methylenebis |
|
|
|
|
GISO, §5215(l) |
|
Natural Gas, Compressed & Liquefied, Tanks
& Cylinders |
|
UFPV, §542 |
|
Non-Asbestiform, Tremolite, Anthophylite,
Actinolite |
|
GISO, §5208.1(h) |
|
Pile drivers, danger of high-voltage overhead
lines |
|
|
ESO-HV, §2947 |
|
Power shovels, danger of high voltage overhead
lines |
|
ESO-HV, §2947 |
|
Saws, Warning Signs |
|
|
|
|
GISO, §4640(g) |
|
Tanks, Warning signs |
|
|
|
|
UFPV, §502 |
|
Traffic Control, Public Streets & Highways |
|
|
CSO, §1598(b) |
|
|
Flaggers |
|
|
|
|
CSO, §1599 |
|
|
|
Employees exposed to Vehicle Traffic at
Excavations |
CSO, §1541(d) |
|
|
|
High Visibility Safety Apparel, Flaggers,
warning garments |
CSO, §1599(d) |
|
|
|
High Visibility Safety Apparel, Flaggers,
during hours of darkness |
CSO, §1599(e) |
|
|
|
High Visibility Safety Apparel, Flaggers,
proper type |
CSO, §1599(f) |
|
|
|
Number of Flaggers |
|
|
CSO, §1599(a) |
|
Transformers |
|
|
|
|
ESO-HV, §2874(e) |
|
|
Warning signs |
|
|
|
GISO, §5208(j)(3) |
|
Tremolite, Non-Asbestiform |
|
|
|
GISO, §5208.1(h) |
|
Vinyl chloride, Signs & Labels |
|
|
|
GISO, §5210(l) |
|
|
Areas containing Hazardous Operations |
|
GISO, §5210(l)(2) |
|
|
Emergency Conditions / Operations, at |
|
GISO, §5210(l)(2) |
|
|
Entrances to Regulated Areas, at |
|
|
GISO, §5210(l)(1) |
|
|
Polyvinyl Chloride Container labeling |
|
|
GISO, §5210(l)(4) |
|
|
Prohibited Information, Instruction |
|
|
GISO, §5210(l)(6) |
|
|
Vinyl Chloride Container labeling |
|
|
GISO, §5210(l)(5) |
|
|
Waste Containers |
|
|
|
GISO, §5210(l)(3) |
|
Warning signs near regulated areas, Ship
Yards |
|
|
SSO, §8358(k)(7) |
WARPERS, Textile Machinery |
|
|
|
|
GISO, §4458 |
WASHING
FACILITIES, General, per CSO |
|
|
|
CSO, §1527 |
|
Roofing, handling coal tar pitch, Specific |
|
|
CSO, §1728 |
WASHING
MACHINES |
|
|
|
|
|
|
”
” ” ” |
|
|
|
See Also APPLIANCES, per ESO |
|
Grounding, Electrical, Cord- &
Plug-connected |
|
|
ESO-LV, §2395.45(a) |
|
” ” ” ” |
|
|
See Also ELECTRICAL
GROUNDING |
|
Laundry & Dry Cleaning |
|
|
|
|
GISO, §4481 |
WASHING TANKS, Pan Washing Tanks for Food Service |
|
|
GISO, §4538 |
WASTE BASKET, Food Waste, Lunch / Brake Rooms |
|
|
GISO, §3368(c) |
WASTE, Combustible, Storage & Disposal |
|
|
|
|
|
Closed Container, Industrial Plant |
|
|
|
GISO, §5551(c) |
|
Closed Container, Processing Plant |
|
|
|
GISO, §5562(c) |
WASTE DISPOSAL |
|
|
|
|
See also under GARBAGE |
|
|
Animal waste, Infected, Aerosol Transmissible
Diseases |
|
GISO, §5199.1 (d) |
|
Asbestos materials |
|
|
|
|
|
|
|
Construction Operations, per CSO |
|
|
CSO, §1529(l)(2) |
|
|
|
Prompt Clean-up & Disposal |
|
CSO, §1529(g)(1)(C) |
|
|
|
Non-mandatory standards |
|
CSO, §1529, Appx F |
|
|
|
Waste disposal Bags, Specification |
|
CSO, §1529(g)(5)(D) |
|
|
General Industry Requirements, per GISO |
|
GISO, §5208(k)(6) |
|
|
|
Non-mandatory standards |
|
GISO, §5208, Appx G |
|
|
Shipyard Standards |
|
|
|
SSO, §8358(g)(1)(C) |
|
|
|
Non-mandatory standards |
|
SSO, §8358, Appx F |
|
Bulk plants |
|
|
|
|
|
|
|
|
Flammable/Combustible liquids, Sewer Disposal
Prohibited |
GISO, §5623 |
|
Cadmium
General industry safety orders |
|
|
GISO, §5207(k)(7) |
|
Chromium (VI) General industry safety
orders |
|
|
GISO, §5206(j)(3) |
|
Chutes for waste disposal |
|
|
|
CSO, §1736,(i) |
|
Combustible Liquids, Sewer Disposal
Prohibited |
|
|
GISO, §5623 |
|
Compaction equipment |
|
|
|
|
|
|
|
|
Application & Scope |
|
|
GISO, §4350 |
|
|
|
Definitions |
|
|
|
GISO, §4351 |
|
|
Balers |
|
|
|
|
GISO, §4353 |
|
|
Construction of |
|
|
|
GISO, §4352 |
|
|
Garbage trucks |
|
|
|
GISO, §4354 |
|
|
Modification of |
|
|
|
GISO, §4352 |
|
|
Mobile Compaction Equipment |
|
|
GISO, §4354 |
|
|
Operating Rules / Requirements |
|
|
GISO, §4355 |
|
|
Reconstruction of |
|
|
|
GISO, §4352 |
|
|
Stationary Compaction Equipment |
|
|
GISO, §4353 |
|
|
|
Operating rules Mandated |
|
GISO, §4353(d) |
|
|
|
Operating Rules |
|
|
GISO, §4355 |
|
Demolition Waste Material Disposal |
|
|
CSO, §1736 |
|
|
Barricading, Without Shute |
|
|
CSO, §1736(f) |
|
|
Removal as work proceeds |
|
|
CSO, §1736(g) |
|
|
Shute Requirements |
|
|
|
CSO, §1736(b)-(j) |
|
Crankcase Oils Disposal in Sewers is
Prohibited |
|
|
GISO, §5623 |
|
Demolition operations |
|
|
|
|
CSO, §1736 |
|
Exhaust Materials |
|
|
|
|
CSO, §1530(c) |
|
Explosives |
|
|
|
|
|
|
|
|
Damaged / Deteriorated Explosives, Disposal of |
|
GISO, §5240 |
|
|
Shipping Boxes, Packing Materials |
|
|
GISO, §5276(c) |
|
Flammable/ Combustible Liquids |
|
|
|
|
|
|
Disposal in Sewers is Prohibited |
|
|
GISO, §5623 |
|
|
Disposal of Residue |
|
|
|
GISO, §5453(f) |
|
Food preparation and processing |
|
|
|
|
|
|
Garbage Disposal Equipment |
|
|
GISO, §4559 |
|
Gas Stations, Drainage & Water
Disposal |
|
|
GISO, §5579 |
|
Methylenebis |
|
|
|
|
GISO, §5215(i) |
|
Mobile collection equipment, Trash & Refuse |
|
|
GISO, Article 60 |
|
|
Application & Scope |
|
|
|
GISO, §4342 |
|
|
Definitions |
|
|
|
|
GISO, §4343 |
|
|
Collection Equipment |
|
|
|
GISO, §4344 |
|
|
Hoist & Tilt-Frame Collection Equipment |
|
GISO, §4345 |
|
Compaction Equipment |
|
|
|
See COMPACTION
EQUIPMENT |
|
Oily Rags, Storage & Disposal |
|
|
|
GISO, §5562(c) |
|
Records, Lead work, Notification of disposal of
Records |
|
GISO, §5198(n)(5) |
|
Residue, Flammable, Spray Coating Operations,
Disposal |
|
GISO, §5453(f) |
|
Service stations, Flammable liquids |
|
|
|
GISO, §5579 |
|
Solid Waste, Disposal Equipment, Food
Service |
|
|
GISO, §4559 |
|
Ventilation, Disposal of Exhaust Materials |
|
|
CSO, §1530(c) |
|
Waste Disposal, per SSO |
|
|
|
SSO, §8397.4(i) |
|
Waste Disposal Containers |
|
|
|
GISO, §3368(c) |
|
Waste, Combustible, Disposal |
|
|
|
|
|
|
Closed Container, Industrial Plant |
|
|
GISO, §5551(c) |
|
|
Closed Container, Processing Plant |
|
|
GISO, §5562(c) |
WASTEWATER
WELLS, Hazardous Locations |
|
|
|
ESO-LV, §2540.10 |
WATER |
|
|
|
|
|
|
|
|
Agricultural Operations, For |
|
|
|
GISO, §3457(c)(1) |
|
|
Access to Drinking Water |
|
|
GISO, §3395(c) |
|
|
Heat Illness Prevention |
|
|
|
GISO, §3395 |
|
|
Maintenance of |
|
|
|
GISO, §3457(c)(3) |
|
Potable Water in Adequate Supply |
|
|
|
GISO, §3363(a) |
|
Clean & Sanitary |
|
|
|
|
GISO, §3363(b) |
|
Common use, Prohibition |
|
|
|
GISO, §3363(e) |
|
Construction Operations |
|
|
|
|
CSO, §1524 |
|
|
Common Drinking Cups / Containers |
|
|
CSO, §1524(a) |
|
|
Drinking Water |
|
|
|
CSO, §1524(a) |
|
|
Non-Potable Water |
|
|
|
CSO, §1524(b) |
|
|
|
Backflow Protection |
|
|
CSO, §1524(b)(3) |
|
|
|
Posting at Outlet |
|
|
CSO, §1524(b)(2) |
|
|
|
Prohibition of Use |
|
|
CSO, §1524(b)(1) |
|
Cups, Drinking |
|
|
|
|
GISO, §3457(c) |
|
Dipping or Pouring of, Prohibition |
|
|
|
GISO, §3363(d) |
|
Dispenser, Designs & Construction |
|
|
|
GISO, §3363(d) |
|
Drinking Supply, Not in Toilet Rooms |
|
|
|
GISO, §3363(c) |
|
Fountains |
|
|
|
|
|
GISO, §3363(b), (c) |
|
Heat Illness Prevention |
|
|
|
|
GISO, §3395 |
|
Labor Camps, In |
|
|
|
|
GISO, §3363 |
|
Maintenance of Supply & Dispenser |
|
|
|
GISO, §3363(b), (c) |
|
Mining Operations |
|
|
|
|
MSO, §6975 |
|
Non-potable Water use for, Prohibition |
|
|
GISO, §3363(f) |
|
|
Posting / Labeling, Non-potable Water |
|
GISO, §3363(g) |
|
|
Backflow Prevention, Non-potable Water |
|
GISO, §3363(h) |
|
Outside Work Locations, per GISO |
|
|
|
GISO, §3395 |
|
Pouring or Dipping of, Prohibition |
|
|
|
GISO, §3363(d) |
|
Ship Building, Ship Repairing & Ship
Breaking Operations |
|
SSO, §8397.4(b) |
|
Tunneling Operations |
|
|
|
|
TSO, §8432 |
WATER CLOSETS |
|
|
|
|
See TOILETS |
|
WATER, Drowning Hazard |
|
|
|
See WATER SAFETY |
|
WATER, Dust Suppression Use |
|
|
|
|
GISO, §5145 |
WATER, floors and platforms free from |
|
|
|
GISO, §3273(a) |
WATER
FOUNTAINS, Swimming Pools & Similar
Installations |
|
|
ESO-LV, Article 79 |
|
Application / Scope |
|
|
|
|
ESO-LV, §2569.1 |
|
Cord & Plug Connected Equipment |
|
|
|
ESO-LV, §2569.7 |
|
Fountains, GFCI Requirement |
|
|
|
ESO-LV, §2569.51 |
|
Ground-Fault Circuit Interrupters Requirement |
|
|
|
|
|
Fountains |
|
|
|
|
ESO-LV, §2569.51 |
|
|
Swimming Pools |
|
|
|
ESO-LV, §2569.31 |
|
Lighting Fixtures, Lighting & Ceiling
Fans |
|
|
ESO-LV, §2569.6 |
|
Pumps |
|
|
|
|
|
ESO-LV, §2569.30 |
|
Receptacles |
|
|
|
|
ESO-LV, §2569.5 |
|
Underwater Equipment |
|
|
|
|
ESO-LV, §2569.20 |
WATER GELS |
|
|
|
|
See EXPLOSIVES |
|
WATER HOSES, Securing on elevated locations |
|
|
|
CSO, §1700 |
WATER PARK /
AQUATIC AMUSEMENT RIDES |
|
|
PARSO, Article 3 |
”
” ” ” ” ” ” ” |
|
See also AMUSEMENT
RIDE SAFETY ORDERS, Permanent |
|
Application |
|
|
|
|
|
PARSO, §3195.10 |
|
Operation & Maintenance |
|
|
|
PARSO, §3195.11 |
WATER, Protection against, per MSO |
|
|
|
MSO, Article 45 |
|
Retaining Dams |
|
|
|
|
MSO, §7175 |
|
Underground Protection |
|
|
|
MSO, §7176 |
WATER-RESISTANT
FOOTWEAR |
|
|
|
|
GISO, §3411(D) |
WATER SAFETY, Work Over or Near Water |
|
|
|
|
|
Agricultural Operations |
|
|
|
|
GISO, §3448 |
|
Construction Operations, per CSO |
|
|
|
|
|
|
Access to or From Wharves, Floats, Barges,
and/or Boats |
CSO, §1603 |
|
|
|
Cat Walks, Ramps, Gangways, etc |
|
CSO, §1603(e) |
|
|
|
Hand Rail |
|
|
|
CSO, §1603(e) |
|
|
|
Illumination |
|
|
|
CSO, §1603(g) |
|
|
|
Jacob's Ladder (Chain Ladder/ Rope) |
|
CSO, §1603(h), & (i) |
|
|
Barges |
|
|
|
|
|
|
|
|
Access Ramp, Adequate Strength |
|
CSO, §1603(a) |
|
|
|
Catwalks over Water |
|
|
CSO, §1603(b) |
|
|
|
Cranes mounted on |
|
|
GISO, §4885 |
|
|
|
Decks Maintained in a Safe Condition, Water Safety |
CSO, §1603.1(b) |
|
|
|
Fall Protection, Water Safety |
|
CSO, §1603.1(d) |
|
|
|
Hand rail/Grab rail, Water Safety |
|
CSO, §1603.1(a) |
|
|
|
Ladder to surface of Water, Water Safety |
CSO, §1602(a)(4) |
|
|
|
Moving of, Marine Terminal Operations |
GISO, §3461 |
|
|
|
Ramp, Adequate Strength |
|
CSO, §1603(a) & (b) |
|
|
|
Walkway |
|
|
|
CSO, §1603(b) |
|
|
|
Working Surface of Barges, Water Safety |
CSO, §1603.1 |
|
|
|
Ramp, Adequate Strength |
|
CSO, §1603(a) |
|
|
|
Fixed Ladder to surface of Water, Water Safety |
CSO, §1602(a)(4) |
|
|
Catwalks over Water |
|
|
|
CSO, §1603(b) |
|
|
Drowning Danger |
|
|
|
CSO, §1602(a) |
|
|
Fall Protection Measures |
|
|
CSO, §1602(a) |
|
|
First Aid/ Medical Assistance |
|
|
CSO, §1602(b) |
|
|
Life lines, Tag lines |
|
|
|
CSO, §1602(a)(3) |
|
|
Life Preservers, Control of Drowning Hazard per
CSO |
CSO, §1602 |
|
|
Lifesaving Boats |
|
|
|
CSO, §1602(a)(3) |
|
|
Personal Flotation Devices (PFD) |
|
|
CSO, §1602(a)(1) |
|
|
Pile Driving Water Safety |
|
|
|
|
|
|
Lifesaving Boats, per |
Article 13 |
|
CSO, §1600(j) |
|
|
|
Ring Buoys |
|
|
|
CSO, §1600(j) & (k) |
|
|
Platforms over Water |
|
|
|
CSO, §1603(d) |
|
|
Railings |
per CSO, §1620 |
|
|
CSO, §1603(d) |
|
|
Ring Buoys |
|
|
|
|
CSO, §1602(a)(2) |
|
|
Walkways, Dredge Discharge Pipe Lines use as |
|
CSO, §1603(a) |
|
General Requirements, per GISO |
|
|
|
GISO, §3389 |
|
Life Preservers, per GISO |
|
|
|
GISO, §3389 |
|
|
Approval of, Coast Guard |
|
|
GISO, §3389(b) |
|
|
Floating Cranes/Derrick operations, During |
|
GISO, §4944 |
|
|
Life Rings |
|
|
|
|
GISO, §3389 |
|
|
Maintenance
and Inspection of |
|
|
GISO, §3389(c) |
|
|
Removal from Service when Damaged |
|
|
GISO, §3389(c) |
|
Life Preservers, per CSO |
|
|
|
|
CSO, §1602 |
|
|
Drowning Danger |
|
|
|
CSO, §1602(a) |
|
|
Exception, w/ Fall Protection Measures |
|
CSO, §1602(a) |
|
|
Life lines, Tag lines |
|
|
|
CSO, §1602(a)(3) |
|
|
Lifesaving Boats |
|
|
|
CSO, §1602(a)(3) |
|
|
Personal Flotation Devices (PFD) |
|
|
CSO, §1602(a)(1) |
|
|
Ring Buoys |
|
|
|
|
CSO, §1602(a)(2) |
|
Mining Operations, per MSO |
|
|
|
MSO, §6980(a) |
|
Paper, Pulp & Paperboard Mills |
|
|
|
GISO, §3448 |
|
Tunneling Operations, per TSO |
|
|
|
TSO, §8427 |
WATER SPRAY, Fixed Extinguishing Systems |
|
|
|
GISO, §6182 |
WATER
TEMPERATURE, Restrooms |
|
|
|
GISO, §3366(d)(2) |
WATTAGE, marking to indicate rating |
|
|
|
ESO-LV, §2340.21 |
WEAR, Parts Subject to, per MSO |
|
|
|
|
MSO, §7011 |
WEATHER
CONDITIONS, per ESO |
|
|
|
|
|
|
Protecting Equipment from, per ESO |
|
|
|
ESO-HV, §2712 |
|
Protecting Workers from, per ESO |
|
|
|
ESO-HV, §2940.3 |
WEATHER
CONDITIONS, per LSSO |
|
|
|
|
|
Logging Operations, Hazardous Weather
Conditions |
|
LSSO, §6253 |
WEATHER
CONDITIONS, per TelSO |
|
|
|
|
|
Inclement Weather, Work Stoppage |
|
|
|
TelSO, §8602(i) |
WEATHER, Heat Illness Prevention, Outdoor |
|
|
|
GISO, §3395 |
|
Access to Drinking Water |
|
|
|
GISO, §3395(c) |
|
|
Maintenance of |
|
|
|
GISO, §3457(c)(3) |
|
Access to Shade |
|
|
|
|
GISO, §3395(d) |
|
|
>85°,
Shade Requirements |
|
|
GISO, §3395(d)(1) |
|
|
≤85°,
Shade Requirements |
|
|
GISO, §3395(d)(2) |
|
Agricultural Industry, Subject to Standard |
|
|
GISO, §3395(a)(2)(A) |
|
Application & Scope |
|
|
|
|
GISO, §3395(a)(2) |
|
Construction Industry, Subject to Standard |
|
|
GISO, §3395(a)(2)(B) |
|
Cool-down Rest Period, Permitted at all Times |
|
|
GISO, §3395(d)(3) |
|
Definitions |
|
|
|
|
|
GISO, §3395(b) |
|
Drinking Water, Access to |
|
|
|
GISO, §3395(c) |
|
|
Maintenance of |
|
|
|
GISO, §3457(c)(3) |
|
High-Heat Procedure |
|
|
|
|
GISO, §3395(e) |
|
Landscaping Industry, Subject to Standard |
|
|
GISO, §3395(a)(2)(C) |
|
|
Landscaping Defined |
|
|
|
GISO, §3395(b) |
|
Oil & Gas Extraction Industry, Subject to
Standard |
|
|
GISO, §3395(a)(2)(D) |
|
Rest Period, Cool-down, Permitted at all Times |
|
|
GISO, §3395(d)(3) |
|
Temperature Triggers |
|
|
|
|
|
|
|
>85°,
Shade Requirements |
|
|
GISO, §3395(d)(1) |
|
|
≤85°,
Shade Requirements |
|
|
GISO, §3395(d)(2) |
|
|
95°,
High-Heat Procedure |
|
|
GISO, §3395(e) |
|
Training |
|
|
|
|
|
GISO, §3395(f) |
|
Transportation of Agri-Products, Construction
& other Heavy Materials, Subject to Standard |
GISO, §3395(a)(2)(E) |
|
|
Exception, Operators in Air-conditioned
Vehicles |
|
GISO, §3395(a)(2)(E) |
WEAVING
OPERATIONS, Exposure to Cotton dust |
|
|
GISO, §5190 |
WEDGES, Used to Disable Saw Guarding Prohibited |
|
|
GISO, §4307(c) |
WEED BURNER, Pressure Hoses |
|
|
|
|
CSO, §1697 |
WEIGHTS &
MEASUREMENTS |
|
|
|
|
CSO, §1938, Appx B, Plate B-3 |
WEIGHTS OF
METALS |
|
|
|
|
CSO, §1938, Appx B, Plate B-4 |
WELDERS, Electrical |
|
|
|
|
|
|
|
Disconnecting Means |
|
|
|
|
|
|
|
Arc Welders |
|
|
|
ESO-LV, §2563.23 |
|
|
Resistance Welders |
|
|
|
ESO-LV, §2563.33 |
|
Over-current Protection |
|
|
|
|
ESO-LV, §2563.22 |
WELDERS’
PLATFORM CAGE, Illustration |
|
|
|
CSO, §1938, Appx B, Plate B-27-a |
WELDING |
|
|
|
|
|
|
|
|
Arc Welding Cutting & Heating |
|
|
See WELDING, ARC, & Cutting & Heating |
|
Acetylene, Generators |
|
|
|
See WELDING, ACETYLENE
GENERATOR SYSTEMS |
|
Acetylene piping |
|
|
|
|
GISO, §4823 |
|
|
Gas Systems Piping for Welding & Cutting |
|
GISO, §4821 |
|
|
Hydraulic Back-Pressure Valves |
|
|
GISO, §4828 |
|
|
Installation of Service Piping |
|
|
GISO, §4825 |
|
|
Painting & Signs |
|
|
|
GISO, §4827 |
|
|
Piping Joints |
|
|
|
GISO, §4824 |
|
|
Signs & Painting |
|
|
|
GISO, §4827 |
|
|
Testing of piping Systems |
|
|
GISO, §4826 |
|
Automatic Reducing Valves, Pressure
Regulators |
|
|
GISO, §4838 |
|
Backflow Protector (Gas Welding) |
|
|
|
GISO, §4845(b) |
|
Booster pumps, Compressors |
|
|
|
GISO, §4840 |
|
Calcium carbide |
|
|
|
|
|
|
|
Opening containers |
|
|
|
GISO, §4818 |
|
|
Storage |
|
|
|
|
GISO, §4819 |
|
Compressor pumps. |
|
|
|
|
GISO, §4840 |
|
Confined Space, Welding in |
|
|
|
GISO, §4851(c) |
|
Definitions |
|
|
|
|
|
GISO, §4795 |
|
Fire prevention and suppression procedures |
|
|
GISO, §4848 |
|
Fuel gas manifolds |
|
|
|
|
GISO, §4835 |
|
Fumes Exposure limits |
|
|
|
|
GISO, §5155, & Appx A |
|
|
Listed, Permissible Exposure Limits |
|
|
GISO, §5155, Table AC-1 |
|
Gas systems |
|
|
|
See WELDING &
CUTTING, GAS SYSTEMS |
|
Generators, Acetylene |
|
|
|
See WELDING, ACETYLENE
GENERATOR SYSTEMS |
|
Hose Requirements, General |
|
|
|
GISO, §4839 |
|
Hose Requirements, Shipyard Operations |
|
|
SSO, §8394 |
|
Inert-Gas Shielded Metal Arc-Welding, General
Industry |
|
GISO, §4853 |
|
” ” ” ” ” ” ” ” |
See also WELDING, ARC, & Cutting & Heating |
|
” ” ” ” ” ” ” ” |
See also WELDING &
CUTTING, Gas Systems |
|
” ” ” ” ” ” ” ” |
See Also WELDING, Electric Welding, Cutting & Heating |
|
Inert Gas Shielded Metal Arc-Welding, Shipyard
Operations |
|
SSO, §8357 |
|
Liquid oxygen, Containers, Locations |
|
|
|
GISO, §4837 |
|
Longshoring Prohibition, Injurious Exposures to
Welding Operations |
GISO, §3470(a)(2) |
|
Manifolding of Cylinders to Headers, Gas
Welding Systems |
|
GISO, Article 86 |
|
|
Fuel Gas Manifolds |
|
|
|
GISO, §4835 |
|
|
Hose |
|
|
|
|
GISO, §4839 |
|
|
Liquid Oxygen |
|
|
|
GISO, §4837 |
|
|
Manifolds, General Requirements |
|
|
GISO, §4834 |
|
|
Oxygen Manifolds |
|
|
|
GISO, §4836 |
|
|
Pressure Regulating |
|
|
|
GISO, §4838 |
|
Manifolds & Hose Connection Requirements,
Shipyard Operations |
SSO, §8393 |
|
Oil & Gas Well Operations, Welding |
|
|
|
PSO-D&P, §6536(d) |
|
Operating procedures |
|
|
|
|
GISO, §4845 |
|
Oxygen manifolds |
|
|
|
|
GISO, §4836 |
|
Oxygen piping |
|
|
|
|
GISO, §4822 |
|
Personal protective equipment |
|
|
|
GISO, §5150 |
|
Pipelines & Equipment, Welding, Hot Work
Method |
|
PSO-D&P, §6536(d) |
|
Piping |
|
|
|
|
|
|
|
|
Acetylene piping |
|
|
|
GISO, §4823 |
|
|
Construction |
|
|
|
GISO, §4821 |
|
|
Hydraulic back-pressure valves |
|
|
GISO, §4828 |
|
|
Installation |
|
|
|
|
GISO, §4825 |
|
|
Joints |
|
|
|
|
GISO, §4824 |
|
|
Materials and design |
|
|
|
GISO, §4821 |
|
|
Oxygen piping |
|
|
|
GISO, §4822 |
|
|
Painting |
|
|
|
|
GISO, §4827 |
|
|
Shutoff valves signs to indicate |
|
|
GISO, §4827 |
|
|
Signs to indicate shutoff valves |
|
|
GISO, §4827 |
|
|
Standards compliance |
|
|
|
GISO, §4821 |
|
|
Testing |
|
|
|
|
GISO, §4826 |
|
Precautions |
|
|
|
|
GISO, §4845 |
|
Pressure Regulating, Automatic Reducing Valves |
|
|
GISO, §4838 |
|
Protective Boots & Shoes, Wet & High
Humidity |
|
|
GISO, §4851(m) |
|
Screens, Welding |
|
|
|
|
GISO, §4851(a) |
|
Service Piping, for All Gasses |
|
|
|
GISO, Article 85 |
|
|
Acetylene Piping |
|
|
|
GISO, §4823 |
|
|
Gas Systems Piping for Welding & Cutting |
|
GISO, §4821 |
|
|
Hydraulic Back-Pressure Valves |
|
|
GISO, §4828 |
|
|
Installation of Service Piping |
|
|
GISO, §4825 |
|
|
Oxygen Piping |
|
|
|
GISO, §4822 |
|
|
Painting & Signs |
|
|
|
GISO, §4827 |
|
|
Piping Joints |
|
|
|
GISO, §4824 |
|
|
Signs & Painting |
|
|
|
GISO, §4827 |
|
|
Testing of piping Systems |
|
|
GISO, §4826 |
|
Shipyard Operations |
|
|
|
See also WELDING,
BRAZING & CUTTING, per SSO |
|
|
Inert Gas Shielded Arc-Welding |
|
|
SSO, §8357 |
|
Tunneling Operations, Welding, Cutting &
Other Hot Work |
|
TSO, §8445(g), (j), (k) |
|
Tunneling Operations, Welding, Cutting &
Other Hot Work |
|
TSO, §8445(g), (j), (k) |
|
Ventilation, Welding, Mechanical systems for
Brazing & Cutting |
GISO, §5150 |
|
|
Hazard communication |
|
|
|
GISO, §5150(f) |
|
” ” |
Construction Operations, per CSO |
|
|
CSO, §1536 |
|
Welding Screens, Arc Welding |
|
|
|
GISO, §4851(a) |
WELDING,
ACETYLENE GENERATOR SYSTEMS |
|
See also WELDING &
CUTTING SYSTEMS, Gas |
|
Approval |
|
|
|
|
|
GISO, §4797(a) |
|
Auxiliary apparatus |
|
|
|
|
GISO, §4797(b) |
|
Calcium Carbide |
|
|
|
|
|
|
|
Storage |
|
|
|
|
GISO, §4818 |
|
|
Opening of containers |
|
|
|
GISO, §4819 |
|
General Requirements |
|
|
|
|
|
|
|
Construction of Generators |
|
|
GISO, §4803 |
|
|
Marking / Labeling |
|
|
|
GISO, §4797 |
|
|
Rating & Pressure Limits of |
|
|
GISO, §4798 |
|
|
Training, Instructions, Operator |
|
|
GISO, §4799 |
|
Hose piping |
|
|
|
|
CSO, §1743(d) |
|
Installation |
|
|
|
|
|
GISO, §4797(c) |
|
Operator training |
|
|
|
|
GISO, §4799 |
|
Permanent Stationary Acetylene Generators |
|
|
|
|
|
Drain Connections |
|
|
|
GISO, §4810 |
|
|
Exits for Houses / Compartments |
|
|
GISO, §4806 |
|
|
Freeze Protection for Generators |
|
|
GISO, §4808 |
|
|
Gas Holders |
|
|
|
GISO, §4813 |
|
|
Generator Escape or Relief Pipes |
|
|
GISO, §4811 |
|
|
Housing of Generators |
|
|
|
GISO, §4803 |
|
|
|
Houses, Outside |
|
|
GISO, §4804 |
|
|
|
Inside Rooms / Compartments |
|
GISO, §4805 |
|
|
Maintenance of |
|
|
|
GISO, §4812 |
|
|
Operation Requirements of |
|
|
GISO, §4812 |
|
|
Outside Houses / Compartments |
|
|
GISO, §4804 |
|
|
Ventilation in Houses / Compartments |
|
GISO, §4807 |
|
|
Water Supply Connections |
|
|
GISO, §4809 |
|
Portable Acetylene Generators |
|
|
|
|
|
|
General Requirements |
|
|
|
GISO, §4815 |
|
|
Operation & Maintenance Requirements |
|
GISO, §4816 |
|
Pressure limitations |
|
|
|
|
GISO, §4799 |
|
Prohibited practices |
|
|
|
|
|
|
|
Air mixing |
|
|
|
|
CSO, §1743(a) |
|
|
Contact w/ oil, grease |
|
|
|
CSO, §1743(c) |
|
|
Contact w/ unalloyed copper |
|
|
CSO, §1743(f) |
|
Welding operations |
|
|
|
See WELDING &
CUTTING, GAS SYSTEMS |
WELDING,
ACETYLENE, OXYGEN, & FUEL GAS |
|
|
|
|
Backflow Protector, Welding |
|
|
|
GISO, §4845(b) |
|
Connections & Hoses |
|
|
|
|
CSO, §1742 |
|
|
Manifold |
|
|
|
|
CSO, §1742(e) |
|
Cylinders |
|
|
|
|
|
GISO, §4650(d) |
|
” |
” |
|
|
|
|
CSO, §1743 |
|
|
Electrical circuits, Prohibition |
|
|
CSO, §1740(e) |
|
|
Construction of |
|
|
|
GISO, §4649(a), (b), (c) |
|
|
Hoisting of |
|
|
|
|
CSO, §1740(d) |
|
|
Leaking of |
|
|
|
|
CSO, §1740(m) |
|
|
Marking of |
|
|
|
|
GISO, §4649(d) |
|
|
Protection |
|
|
|
|
CSO, §1740(c), (h), (i), (j) |
|
|
|
Valve |
|
|
|
GISO, §4650(c) |
|
|
Prohibitions |
|
|
|
CSO, §1743(h) |
|
|
Storage |
|
|
|
|
CSO, §1740(b), (g) |
|
|
Transport/Handling |
|
|
|
CSO, §1740(c) |
|
Exposure limits, Airborne Contaminant, Exposure
limit |
|
GISO, §5155, & Appx A |
|
|
Listed, Permissible Exposure Limits |
|
|
GISO, §5155, Table AC-1 |
|
General Precautions |
|
|
|
|
CSO, §1743 |
|
Hose & Connections |
|
|
|
|
CSO, §1742 |
|
Manifold |
|
|
|
|
|
CSO, §1742(e) |
|
Maximum Pressure |
|
|
|
|
CSO, §1743(b) |
|
Pressure Regulators |
|
|
|
|
CSO, §1741 |
|
Storage & Use of Cylinders |
|
|
|
CSO, §1740 |
|
Transfer prohibited |
|
|
|
|
CSO, §1740(f) |
|
Unalloyed copper contact with |
|
|
|
CSO, §1743(f) |
|
Use of Cylinders |
|
|
|
|
CSO, §1740 |
WELDING, ARC, & Cutting & Heating |
|
|
|
GISO, Article 90 |
|
|
Application |
|
|
|
GISO, §4850 |
|
Arc Welding Cutting & Heating |
|
|
|
GISO, §4851 |
|
Arc Welding, Inert-Gas Metal |
|
|
|
GISO, §4853 |
|
Equipment, Welding, Disconnecting means |
|
|
ESO-LV, §2563.23 |
|
Fumes, Air Contaminants, Exposure limits |
|
|
GISO, §5155, & Appx A |
|
|
Listed, Permissible Exposure Limits |
|
|
GISO, §5155, Table AC-1 |
|
Inert-Gas Shielded Metal Arc-Welding, General
Industry |
|
GISO, §4853 |
|
” ” ” ” ” ” ” ” |
See also WELDING &
CUTTING, Gas Systems |
|
” ” ” ” ” ” ” ” |
See Also WELDING, Electric Welding, Cutting & Heating |
|
Inert Gas Shielded Metal Arc-Welding, Shipyard
Operations |
|
SSO, §8357 |
|
Installation of Equipment |
|
|
|
GISO, §4850(b) |
|
Maintenance |
|
|
|
|
GISO, §4850(b) |
|
Protective Equipment |
|
|
|
|
GISO, §4851(a), (m) |
|
Resistance Welding |
|
|
|
|
GISO, §4852 |
|
Ventilation & Personal Protection |
|
|
|
GISO, §5150 |
|
|
Chlorinated Hydrocarbons |
|
|
GISO, §5150(e) |
|
|
Hazard commmunication |
|
|
|
GISO, §5150(f) |
|
|
Improper Use of Welding Gases |
|
|
GISO, §5150(d) |
|
|
Labeling, Precautionary |
|
|
|
GISO, §5150(e) |
|
|
Mechanical Ventilation, Indoors |
|
|
GISO, §5150(a) |
|
|
Toxic Substances Used in Enclosed Spaces |
|
GISO, §5150(b) |
|
|
Toxic Substances Used in Open Air |
|
|
GISO, §5150(c) |
|
Work Site Requirements |
|
|
|
|
GISO, §4851 |
WELDING,
BRAZING, & CUTTING, per CSO |
|
|
|
|
|
Coated metals. flammability precautions |
|
|
CSO, §1537 |
|
Fumes, Air Contaminants, Exposure limits |
|
|
GISO, §5155, & Appx A |
|
|
Listed, Permissible Exposure Limits |
|
|
GISO, §5155, Table AC-1 |
|
Mechanical Ventilation for Indoor Operations |
|
|
CSO, §1536 |
|
|
Respiratory Protection Alternative |
|
|
CSO, §1536(a)(2) |
|
Prohibited practices |
|
|
|
|
|
|
|
Air mixing |
|
|
|
|
CSO, §1743(a) |
|
|
Contact w/ oil, grease |
|
|
|
CSO, §1743(c) |
|
|
Contact w/ unalloyed copper |
|
|
CSO, §1743(f) |
|
Toxic Substances in Enclosed Spaces |
|
|
|
CSO, §1536(b) |
|
|
Local Exhaust Required |
|
|
|
CSO, §1536(b)(1) |
|
|
Supplied Air Respirator as Alternative |
|
CSO, §1536(b)(2) |
|
Toxic Substances in Open Air |
|
|
|
CSO, §1536(c) |
|
|
Respiratory Protection per |
|
|
CSO, §1536(c)(1), (2) |
|
Improper Use of Welding Gases |
|
|
|
CSO, §1536(d) |
|
Chlorinated Hydrocarbons |
|
|
|
CSO, §1536(e) |
|
Labeling, Precautionary |
|
|
|
|
CSO, §1536(f) |
|
Ventilation, Mechanical Systems |
|
|
|
CSO, §1536 |
|
Welding, Cutting, & Heating, Of Coated
Metals |
|
|
CSO, §1537 |
WELDING,
BRAZING & CUTTING, per GISO |
|
|
|
|
|
Fumes, Air Contaminants, Exposure limits |
|
|
GISO, §5155, & Appx A |
|
|
Listed, Permissible Exposure Limits |
|
|
GISO, §5155, Table AC-1 |
|
Ventilation & Personal Protection |
|
|
|
GISO, §5150 |
|
|
Chlorinated Hydrocarbons |
|
|
GISO, §5150(e) |
|
|
Hazard communication |
|
|
|
GISO, §5150(f) |
|
|
Improper Use of Welding Gases |
|
|
GISO, §5150(d) |
|
|
Labeling, Precautionary |
|
|
|
GISO, §5150(e) |
|
|
Mechanical Ventilation, Indoors |
|
|
GISO, §5150(a) |
|
|
Toxic Substances Used in Enclosed Spaces |
|
GISO, §5150(b) |
|
|
Toxic Substances Used in Open Air |
|
|
GISO, §5150(c) |
WELDING,
BRAZING & CUTTING, per SSO |
|
|
|
SSO, Article 7 |
|
Fuel Gas Cylinders |
|
|
|
|
SSO, §8395 |
|
Hose |
|
|
|
|
|
SSO, §8394 |
|
Hose Connection Requirements |
|
|
|
SSO, §8393 |
|
Manifolds & Hose Connection Requirements |
|
|
SSO, §8393 |
|
Welding, Cutting & Heating, Other
Provisions in GISO |
|
SSO, §8392 |
WELDING &
CUTTING, GAS SYSTEMS |
|
|
|
GISO, Group 10 |
|
|
Application / Purpose |
|
|
|
GISO, §4794 |
|
|
Definitions |
|
|
|
|
GISO, §4795 |
|
Acetylene Generator Systems |
|
|
|
|
|
|
Approval |
|
|
|
|
GISO, §4797(a) |
|
|
Auxiliary apparatus |
|
|
|
GISO, §4797(b) |
|
|
Calcium Carbide |
|
|
|
|
|
|
|
Storage |
|
|
|
GISO, §4818 |
|
|
|
Opening of containers |
|
|
GISO, §4819 |
|
|
General Requirements |
|
|
|
|
|
|
|
Construction of Generators |
|
GISO, §4803 |
|
|
|
Marking / Labeling |
|
|
GISO, §4797 |
|
|
|
Rating & Pressure Limits of |
|
GISO, §4798 |
|
|
|
Training, Instructions, Operator |
|
GISO, §4799 |
|
|
Hose piping |
|
|
|
CSO, §1743(d) |
|
|
Installation |
|
|
|
|
GISO, §4797(c) |
|
|
Operator training |
|
|
|
GISO, §4799 |
|
|
Permanent Stationary Acetylene Generators |
|
|
|
|
|
Drain Connections |
|
|
GISO, §4810 |
|
|
|
Exits for Houses / Compartments |
|
GISO, §4806 |
|
|
|
Freeze Protection for Generators |
|
GISO, §4808 |
|
|
|
Gas Holders |
|
|
GISO, §4813 |
|
|
|
Generator Escape or Relief Pipes |
|
GISO, §4811 |
|
|
|
Housing of Generators |
|
|
GISO, §4803 |
|
|
|
|
Houses, Outside |
|
GISO, §4804 |
|
|
|
|
Inside Rooms / Compartments |
GISO, §4805 |
|
|
|
Maintenance of |
|
|
GISO, §4812 |
|
|
|
Operation Requirements of |
|
GISO, §4812 |
|
|
|
Outside Houses / Compartments |
|
GISO, §4804 |
|
|
|
Ventilation in Houses / Compartments |
GISO, §4807 |
|
|
|
Water Supply Connections |
|
GISO, §4809 |
|
|
Portable Acetylene Generators |
|
|
|
|
|
|
General Requirements |
|
|
GISO, §4815 |
|
|
|
Operation & Maintenance Requirements |
GISO, §4816 |
|
|
Pressure limitations |
|
|
|
GISO, §4799 |
|
Approval Requirements |
|
|
|
|
GISO, §4797 |
|
Calcium Carbide |
|
|
|
|
GISO, Article 84 |
|
|
Opening Containers of |
|
|
|
GISO, §4819 |
|
|
Storage |
|
|
|
|
GISO, §4818 |
|
Carbide Feed Generators |
|
|
See Acetylene Generator Systems under WELDING & CUTTING, Gas
Systems |
|
Compressor or Booster Pumps |
|
|
|
GISO, §4840 |
|
Cylinders, Gas |
|
|
|
See CYLINDERS |
|
|
Fire Prevention & Suppression Procedure |
|
|
GISO, §4848 |
|
Manifolding of Cylinders to Headers |
|
|
|
GISO, Article 86 |
|
|
Fuel Gas Manifolds |
|
|
|
GISO, §4835 |
|
|
Hose |
|
|
|
|
GISO, §4839 |
|
|
Liquid Oxygen |
|
|
|
GISO, §4837 |
|
|
Manifolds, General Requirements |
|
|
GISO, §4834 |
|
|
Oxygen Manifolds |
|
|
|
GISO, §4836 |
|
|
Pressure Regulating |
|
|
|
GISO, §4838 |
|
Marking / Labeling |
|
|
|
|
GISO, §4797 |
|
Operating Procedures for Gas Welding |
|
|
GISO, §4845 |
|
Personal Protection & Ventilation |
|
|
|
GISO, §5150 |
|
|
Chlorinated Hydrocarbons |
|
|
GISO, §5150(e) |
|
|
Improper Use of Welding Gases |
|
|
GISO, §5150(d) |
|
|
Labeling, Precautionary |
|
|
|
GISO, §5150(e) |
|
|
Mechanical Ventilation, Indoors |
|
|
GISO, §5150(a) |
|
|
Toxic Substances Used in Enclosed Spaces |
|
GISO, §5150(b) |
|
|
Toxic Substances Used in Open Air |
|
|
GISO, §5150(c) |
|
Piping for All Gasses |
|
|
|
See Service PIPES, PIPE
LINES |
|
|
Precautions for Gas Welding |
|
|
|
GISO, §4845 |
|
Service Piping for All Gasses |
|
|
|
GISO, Article 85 |
|
|
Acetylene Piping |
|
|
|
GISO, §4823 |
|
|
Gas Systems Piping for Welding & Cutting |
|
GISO, §4821 |
|
|
Hydraulic Back-Pressure Valves |
|
|
GISO, §4828 |
|
|
Installation of Service Piping |
|
|
GISO, §4825 |
|
|
Oxygen Piping |
|
|
|
GISO, §4822 |
|
|
Painting & Signs |
|
|
|
GISO, §4827 |
|
|
Piping Joints |
|
|
|
GISO, §4824 |
|
|
Signs & Painting |
|
|
|
GISO, §4827 |
|
|
Testing of piping Systems |
|
|
GISO, §4826 |
|
Ventilation & Personal Protection |
|
|
|
GISO, §5150 |
|
|
Chlorinated Hydrocarbons |
|
|
GISO, §5150(e) |
|
|
Hazard communication |
|
|
|
GISO, §5150(f) |
|
|
Improper Use of Welding Gases |
|
|
GISO, §5150(d) |
|
|
Labeling, Precautionary |
|
|
|
GISO, §5150(e) |
|
|
Mechanical Ventilation, Indoors |
|
|
GISO, §5150(a) |
|
|
Toxic Substances Used in Enclosed Spaces |
|
GISO, §5150(b) |
|
|
Toxic Substances Used in Open Air |
|
|
GISO, §5150(c) |
WELDING, Electric Welding, Cutting & Heating |
|
|
|
GISO, Article 90 |
|
|
Application |
|
|
|
GISO, §4850 |
|
Arc Welding Cutting & Heating |
|
|
|
GISO, §4851 |
|
Arc Welding, Inert-Gas Metal |
|
|
|
GISO, §4853 |
|
Inert-Gas Metal Arc Welding |
|
|
|
GISO, §4853 |
|
Installation of Equipment |
|
|
|
GISO, §4850(b) |
|
Maintenance |
|
|
|
|
GISO, §4850(b) |
|
Resistance Welding |
|
|
|
|
GISO, §4852 |
|
Ventilation & Personal Protection |
|
|
|
GISO, §5150 |
|
|
Chlorinated Hydrocarbons |
|
|
GISO, §5150(e) |
|
|
Hazard communication |
|
|
|
GISO, §5150(f) |
|
|
Improper Use of Welding Gases |
|
|
GISO, §5150(d) |
|
|
Labeling, Precautionary |
|
|
|
GISO, §5150(e) |
|
|
Mechanical Ventilation, Indoors |
|
|
GISO, §5150(a) |
|
|
Toxic Substances Used in Enclosed Spaces |
|
GISO, §5150(b) |
|
|
Toxic Substances Used in Open Air |
|
|
GISO, §5150(c) |
WELDING, Hot Work Procedures & Permits |
|
|
|
PSO-R,T&H, §6777 |
WELDING, of Elevators |
|
|
|
|
|
ElevSO, §3121.13 |
WELDING, Resistance welding |
|
|
|
|
GISO, §4852 |
|
Disconnecting means of |
|
|
|
|
ESO-LV, §2563.33 |
WELFARE &
LOCATION CHECKS, Logging Operations |
|
|
LSSO, §6258 |
WELLS, GAS
& OIL, Drilling & Production |
|
|
|
|
|
Change Rooms |
|
|
|
|
|
|
|
Permanent Change Rooms, per Article 9,
GISO |
|
PSO-D&P, §6514(a) |
|
|
|
Clean, Orderly, Sanitary Condition |
|
PSO-D&P, §6514(b) |
|
|
|
Location of |
|
|
|
PSO-D&P, §6514(c) |
|
|
|
Shower Facilities, Number of |
|
PSO-D&P, §6514(a) |
|
|
Well Drilling & Servicing Operations |
|
|
PSO-D&P, §6515 |
|
|
|
Clean, Orderly, Sanitary Condition |
|
PSO-D&P, §6515(b) |
|
|
|
Lighting, Heating & Ventilation |
|
PSO-D&P, §6515(b) |
|
|
|
Location of |
|
|
|
PSO-D&P, §6515(a) |
|
Clothing, wearing of, per Article 10, GISO |
|
|
PSO-D&P, §6513 |
|
Drilling Operation |
|
|
|
|
|
|
|
Fall Protection Requirements, Derrick / Mast
Work |
|
PSO-D&P, §6580 |
|
|
Tools, Handling Heavy Tools at Drilling Wells |
|
PSO-D&P, §6607 |
|
Electrical Equipment & Wiring per
Electrical Safety Orders |
|
PSO-D&P, §6527 |
|
Emergency Medical Services |
|
|
|
PSO-D&P, §6512 |
|
Emergency Stop Device, Drilling Equipment |
|
|
PSO-D&P, §6625 |
|
Equipment & Pipe Lines |
|
|
|
|
|
|
|
Blinding or Isolating of Equipment & Pipe
Lines |
|
PSO-D&P, §6536 |
|
|
|
Blinding Design |
|
|
PSO-D&P, §6536(b) |
|
|
|
|
Open or Closed Indicators |
PSO-D&P, §6536(e) |
|
|
|
Employee Protection by |
|
|
PSO-D&P, §6536(a) |
|
|
|
Ventilation Requirements |
|
PSO-D&P, §6536(c) |
|
|
|
Welding, Hot Work Method |
|
PSO-D&P, §6536(d) |
|
|
Opening of Equipment & Pipe Lines |
|
|
PSO-D&P, §6535 |
|
|
|
Emptying of Content |
|
|
PSO-D&P, §6535(b) |
|
|
|
Ignition Source, Elimination of |
|
PSO-D&P, §6535(c) |
|
|
|
Relieve of Pressure |
|
|
PSO-D&P, §6535(a) |
|
Equipment & Tools, Miscellaneous |
|
|
|
PSO-D&P, §6646 |
|
Fall Protection Requirements |
|
|
See FALL PROTECTION
REQUIREMENTS, per PSO-D&P |
|
Flammable Gases Or Vapors, Hazardous Areas |
|
See FLAMMABLE GASES OR
VAPORS, Hazardous Areas |
|
Flammable Waste Gasses & Vapor |
|
|
See FLAMMABLE WASTE
GASSES & VAPOR |
|
Flywheel Guarding, Prime Movers |
|
|
|
PSO-D&P, §6682 |
|
Fire Prevention |
|
|
|
|
|
|
|
Cleaning oil restrictions |
|
|
|
PSO-D&P, §6520 |
|
|
Drainage control |
|
|
|
PSO-D&P, §6538 |
|
|
Fired equipment location |
|
|
PSO-D&P, §6526 |
|
|
Fire fighting equipment |
|
|
|
PSO-D&P, §6519 |
|
|
Flammable and combustible liquid transfer by
air displacement |
PSO-D&P, §6525 |
|
|
Flammable waste Gases and Vapors |
|
|
PSO-D&P, §6524 |
|
|
Hazardous area testing |
|
|
|
PSO-D&P, §6521 |
|
|
Pipe lines |
|
|
|
|
|
|
|
|
Blinding procedures |
|
|
PSO-D&P, §6536 |
|
|
|
Opening procedures |
|
|
PSO-D&P, §6535 |
|
|
Smoking restrictions |
|
|
|
PSO-D&P, §6518 |
|
|
Spontaneous ignition precautions |
|
|
PSO-D&P, §6522 |
|
|
Static electricity |
|
|
|
PSO-D&P, §6523 |
|
Fittings, Pipe Lines & Valves |
|
|
|
PSO-D&P, §6533 |
|
|
Drill Pipe & Well Casing / Tubing Excluded |
|
PSO-D&P, §6533(a) |
|
|
General Requirements |
|
|
|
PSO-D&P, §6533(a) |
|
|
Inspection Requirements |
|
|
PSO-D&P, §6533(b) |
|
|
Pressure Relieve Devices & Valves |
|
|
PSO-D&P, §6533(c) |
|
Hazardous Areas |
|
|
|
|
PSO-D&P, §6521 |
|
|
Control of Sources of Ignition |
|
|
PSO-D&P, §6521(a) |
|
|
Flammable Waste Gasses & Vapor, Hazard
Control |
|
PSO-D&P, §6524 |
|
|
|
Burning, Controlled |
|
|
PSO-D&P, §6524(a) |
|
|
|
Control Hazards Associated with |
|
PSO-D&P, §6524(a) |
|
|
|
Flares, use of |
|
|
PSO-D&P, §6524(a), (c) |
|
|
|
Employees Entry Restriction |
|
PSO-D&P, §6524(b) |
|
|
|
Remote Ignition, Controlled |
|
PSO-D&P, §6524(b) |
|
|
|
Remote Ignition, Failure |
|
|
PSO-D&P, §6524(e) |
|
|
|
Release of Gasses & Vapor Prevention |
PSO-D&P, §6524(d) |
|
|
|
Remote Ignition, Controlled |
|
PSO-D&P, §6524(b) |
|
|
|
Testing for Releases before Employees Entry |
PSO-D&P, §6524(e) |
|
|
Ignition Sources |
|
|
|
|
|
|
|
Control of |
|
|
|
PSO-D&P, §6521(a) |
|
|
|
Prohibited, in Flammable Vapor / Gas |
|
PSO-D&P, §6521(b ) |
|
|
Spontaneous Ignition |
|
|
|
PSO-D&P, §6522 |
|
|
|
Iron Sulfide Management |
|
PSO-D&P, §6522(a) |
|
|
|
Steel Wool, use with Lime |
|
PSO-D&P, §6522(b) |
|
|
Static Electricity, Control of |
|
|
PSO-D&P, §6523(a) |
|
|
|
Grounding of Steel Derricks & Masts |
|
PSO-D&P, §6523(b) |
|
|
Testing of Gas & Vapor |
|
|
|
PSO-D&P, §6531 |
|
|
Transfer of Flammable / Combustible Liquids |
|
|
|
|
|
Compressed Air, Use Prohibited for Tanks |
PSO-D&P, §6525(a) |
|
|
|
|
Exceptions listed |
|
PSO-D&P, §6525(a) |
|
|
Well Safety |
|
|
|
|
|
|
|
|
Electrical Equipment |
|
|
PSO-D&P, §6527 |
|
|
|
Fired Equipment Restriction near Wells |
PSO-D&P, §6526(a) |
|
|
|
Safety Provisions & Precautions |
|
PSO-D&P, §6655 |
|
Housekeeping of Oil Storage Facilities |
|
|
PSO-D&P, §6539 |
|
Identification of Wells |
|
|
|
|
PSO-D&P, §6556 |
|
Injury & Illness Prevention Program per §3203,
GISO |
|
PSO-D&P, §6507 |
|
|
Safety Provisions & Precautions |
|
|
PSO-D&P, §6655 |
|
Inspection Program, Pressure Vessels &
Boilers |
|
|
PSO-D&P, §6551(c) |
|
Liquids, Loading & Unloading Operations |
|
|
PSO-D&P, §6651 |
|
|
Loading & Unloading Platforms |
|
|
PSO-D&P, §6652 |
|
|
Wharves & Piers, at |
|
|
|
PSO-D&P, §6659 |
|
Maintenance |
|
|
|
|
|
|
|
Fall Protection Requirements, Derrick / Mast
Work |
|
PSO-D&P, §6580 |
|
Personal Protective Equipment, per Article 10,
GISO |
|
PSO-D&P, §6513 |
|
Pipe Lines |
|
|
|
|
See also Equipment & Pipe Lines under this
heading |
|
|
Fittings, Pipe Lines & Valves |
|
|
PSO-D&P, §6533 |
|
|
|
Drill Pipe & Well Casing / Tubing Excluded |
PSO-D&P, §6533(a) |
|
|
|
General Requirements |
|
|
PSO-D&P, §6533(a) |
|
|
|
Inspection Requirements |
|
PSO-D&P, §6533(b) |
|
|
|
Pressure Relieve Devices & Valves |
|
PSO-D&P, §6533(c) |
|
Pressure Vessels & Boilers, Inspection
Program |
|
|
PSO-D&P, §6551(c) |
|
Pull Rope, Wire |
|
|
|
|
PSO-D&P, §6640 |
|
Pumping Machinery & Equipment |
|
|
|
PSO-D&P, Article 37 |
|
|
Access to the Walking Beam |
|
|
PSO-D&P, §6632 |
|
|
Attractive Nuisance Guards: Well-Pumping Units |
|
PSO-D&P, §6633 |
|
|
Catheads |
|
|
|
|
PSO-D&P, §6642 |
|
|
|
Chain Used for Spinning Lines |
|
PSO-D&P, §6645 |
|
|
|
Lines Used on Catheads |
|
|
PSO-D&P, §6644 |
|
|
Construction & Maintenance |
|
|
PSO-D&P, §6630 |
|
|
Guarding |
|
|
|
|
PSO-D&P, §6631 |
|
|
Illumination / Lighting |
|
|
|
PSO-D&P, §6657 |
|
|
Pumps & Pump Pressure Relief Devices |
|
PSO-D&P, §6634 |
|
|
Safety Provisions & Precautions |
|
|
PSO-D&P, §6655 |
|
|
Shafts & Equipment at Oil Wells |
|
|
PSO-D&P, §6661 |
|
|
Weight Indicators for Wire Rope Hoisting Lines |
|
PSO-D&P, §6690 |
|
Safety Provisions & Precautions |
|
|
|
PSO-D&P, §6655 |
|
|
Injury & Illness Prevention Program |
|
|
PSO-D&P, §6507 |
|
Servicing Machinery & Equipment |
|
|
|
PSO-D&P, Article 35 |
|
|
Application / Scope |
|
|
|
PSO-D&P, §6621 |
|
|
Brakes & Brake Control Mechanism |
|
|
PSO-D&P, §6626 |
|
|
Catheads |
|
|
|
|
PSO-D&P, §6642 |
|
|
|
Chain Used for Spinning Lines |
|
PSO-D&P, §6645 |
|
|
|
Lines Used on Catheads |
|
|
PSO-D&P, §6644 |
|
|
Drilling Equipment, Construction &
Maintenance |
|
PSO-D&P, §6624 |
|
|
Emergency Stop Device |
|
|
|
PSO-D&P, §6625 |
|
|
Guarding |
|
|
|
|
PSO-D&P, §6622 |
|
|
Illumination / Lighting |
|
|
|
PSO-D&P, §6657 |
|
|
Line Spoolers & Deadline Stabilizers |
|
|
PSO-D&P, §6688 |
|
|
Power Tongs Control Mechanism |
|
|
PSO-D&P, §6628 |
|
|
Safety Provisions & Precautions |
|
|
PSO-D&P, §6655 |
|
|
Weight Indicators for Wire Rope Hoisting Lines |
|
PSO-D&P, §6690 |
|
|
Well Servicing Equipment, Construction &
Maintenance |
PSO-D&P, §6624 |
|
Shower Facilities, Number of |
|
|
|
PSO-D&P, §6514(a) |
|
Storage Facilities, Housekeeping of Oils
Storage |
|
|
PSO-D&P, §6539 |
|
Tools, Handling Heavy Tools at Drilling Wells |
|
|
PSO-D&P, §6607 |
WELLS, OIL
& GAS, Pumping Machinery & Equipment |
|
|
PSO-D&P, Article 37 |
|
Access to the Walking Beam |
|
|
|
PSO-D&P, §6632 |
|
Air Compressors, Engines Powering |
|
|
|
PSO-D&P, §6554 |
|
Attractive Nuisance Guards: Well-Pumping Units |
|
|
PSO-D&P, §6633 |
|
Boilers |
|
|
|
|
See BOILERS |
|
|
Construction & Maintenance |
|
|
|
PSO-D&P, §6630 |
|
Dead line stabilizers |
|
|
|
|
PSO-D&P, §6688 |
|
Derricks & Masts |
|
|
|
|
PSO-D&P, §6558 |
|
|
Construction and maintenance |
|
|
PSO-D&P, §6568 |
|
|
Crown blocks |
|
|
|
PSO-D&P, §6571 |
|
|
Crown platforms and railings |
|
|
PSO-D&P, §6562 |
|
|
Equipment and tool requirements |
|
|
PSO-D&P, §6603 |
|
|
Escape lines |
|
|
|
PSO-D&P, §6574 |
|
|
Escape routes, Auxiliary Means |
|
|
PSO-D&P, §6573 |
|
|
Equipment in |
|
|
|
PSO-D&P, §6603 |
|
|
External platforms |
|
|
|
PSO-D&P, §6561 |
|
|
Fingers finger boards and finger braces |
|
PSO-D&P, §6569 |
|
|
Floor access and exits |
|
|
|
PSO-D&P, §6579 |
|
|
Gin poles |
|
|
|
|
PSO-D&P, §6563 |
|
|
Guy lines |
|
|
|
|
PSO-D&P, §6566 |
|
|
Internal platforms |
|
|
|
PSO-D&P, §6560 |
|
|
Ladders |
|
|
|
|
PSO-D&P, §6564 |
|
|
Ladderway openings |
|
|
|
PSO-D&P, §6565 |
|
|
Materials in |
|
|
|
PSO-D&P, §6603 |
|
|
Safety belts and lanyards |
|
|
PSO-D&P, §6580 |
|
|
Stabbing boards |
|
|
|
PSO-D&P, §6570 |
|
|
Tools in |
|
|
|
|
PSO-D&P, §6603 |
|
Electrical Equipment |
|
|
|
|
PSO-D&P, §6527 |
|
Escape routes, Auxiliary Means |
|
|
|
PSO-D&P, §6573 |
|
Experimental equipment |
|
|
|
|
PSO-D&P, §6886 |
|
Fittings, Pipe Lines & Valves |
|
|
|
PSO-D&P, §6533 |
|
|
Drill Pipe & Well Casing / Tubing Excluded |
|
PSO-D&P, §6533(a) |
|
|
General Requirements |
|
|
|
PSO-D&P, §6533(a) |
|
|
Inspection Requirements |
|
|
PSO-D&P, §6533(b) |
|
|
Pressure Relieve Devices & Valves |
|
|
PSO-D&P, §6533(c) |
|
Gas Compressors, Engines Powering |
|
|
|
PSO-D&P, §6554 |
|
Gas Compressors & Gas Plant Requirements |
|
|
PSO-D&P, §6553 |
|
|
Discharge Line, Pressure Relief Device
Requirement |
PSO-D&P, §6553(b) |
|
|
Discharge Outlet of Pressure Relief Device |
|
PSO-D&P, §6553(c) |
|
|
Inlet Scrubber, Liquids in Incoming Gas |
|
PSO-D&P, §6553(d) |
|
|
Pre-Maintenance Procedure, locking / Blocking |
|
PSO-D&P, §6553(f) |
|
|
Shut-off Valve, Gas Line |
|
|
|
PSO-D&P, §6553(e) |
|
|
Stationary Engine Driving Compressors |
|
PSO-D&P, §6554 |
|
|
Valve, Return Flow Protection |
|
|
PSO-D&P, §6553(a) |
|
Gas & Vapor testing |
|
|
|
|
PSO-D&P, §6531 |
|
Gin Pole Mast, Telescoping |
|
|
|
PSO-D&P, §6584 |
|
Guarding |
|
|
|
|
|
PSO-D&P, §6631 |
|
Heavy tool, Handling of |
|
|
|
PSO-D&P, §6607 |
|
Hoses & Standpipes |
|
|
|
|
PSO-D&P, §6609 |
|
Internal combustion engines |
|
|
|
|
|
|
Application / Scope of §6684 |
|
|
PSO-D&P, §6684(a) |
|
|
Batteries, Electrical Storage |
|
|
PSO-D&P, §6684(h) |
|
|
Compressors, Air or Gas |
|
|
|
PSO-D&P, §6554 |
|
|
Cylinder Cooks |
|
|
|
PSO-D&P, §6684(e) |
|
|
Electrical Accessories for ICE |
|
|
PSO-D&P, §6684(f), (g) |
|
|
Electrical Storage Batteries |
|
|
PSO-D&P, §6684(h) |
|
|
Exhaust System Maintenance |
|
|
PSO-D&P, §6684(a) |
|
|
Flywheels |
|
|
|
|
PSO-D&P, §6682 |
|
|
Power Controls |
|
|
|
PSO-D&P, §6681 |
|
|
Safety Precautions |
|
|
|
PSO-D&P, §6684(b), (d), (g) |
|
|
|
For Compressors, Air or Gas |
|
PSO-D&P, §6554 |
|
|
Starters for ICE |
|
|
|
PSO-D&P, §6685 |
|
Ladders |
|
|
|
|
|
PSO-D&P, §6564 |
|
Ladderway openings |
|
|
|
|
PSO-D&P, §6565 |
|
Lighting |
|
|
|
|
|
PSO-D&P, §6657 |
|
Line spoolers |
|
|
|
|
PSO-D&P, §6688 |
|
Machinery |
|
|
|
|
|
|
|
|
Brakes |
|
|
|
|
PSO-D&P, §6626 |
|
|
Construction |
|
|
|
PSO-D&P, §6624 |
|
|
Emergency Stop Devices |
|
|
PSO-D&P, §6625 |
|
|
Maintenance |
|
|
|
PSO-D&P, §6624 |
|
Masts |
|
|
|
|
|
|
|
|
Cantilever Derricks & Masts, Portable |
|
PSO-D&P, §6595 |
|
|
Construction |
|
|
|
PSO-D&P, §6568 |
|
|
Crown blocks |
|
|
|
PSO-D&P, §6571 |
|
|
Crown Platforms & Railings |
|
|
PSO-D&P, Article 25 |
|
|
|
Access & Lubrication |
|
|
PSO-D&P, §6592(a) |
|
|
|
|
Ladder Requirements |
|
PSO-D&P, §6592(b) |
|
|
|
Gin Pole Masts, Stationary or Portable |
PSO-D&P, §6589 |
|
|
|
Portable Cantilever Derricks & Masts |
|
PSO-D&P, §6590 |
|
|
|
Portable Jackknife Derricks & Masts |
|
PSO-D&P, §6591 |
|
|
|
Telescoping Derricks & Masts |
|
PSO-D&P, §6591 |
|
|
Equipment and tool requirements |
|
|
PSO-D&P, §6603 |
|
|
Escape lines. |
|
|
|
PSO-D&P, §6574 |
|
|
Fire Escapes, Auxiliary Means |
|
|
PSO-D&P, §6573 |
|
|
Fingers, Finger Boards & Finger Braces |
|
PSO-D&P, §6569 |
|
|
Floor access and Exits |
|
|
|
PSO-D&P, §6579 |
|
|
Guarding |
|
|
|
|
PSO-D&P, §6636 |
|
|
Guying |
|
|
|
|
PSO-D&P, §6586 |
|
|
Hydraulic lifts |
|
|
|
PSO-D&P, §6583 |
|
|
Ladders |
|
|
|
|
PSO-D&P, §6599 |
|
|
Maintenance |
|
|
|
PSO-D&P, §6568 |
|
|
Pipelines & Pipes |
|
|
See PIPELINES |
|
|
|
Pipe racking supports |
|
|
|
PSO-D&P, §6596 |
|
|
Platforms Access Runways |
|
|
PSO-D&P, §6594 |
|
|
Platforms, Crown, & Railings |
|
|
PSO-D&P, Article 25 |
|
|
|
Access & Lubrication |
|
|
PSO-D&P, §6592(a) |
|
|
|
|
Ladder Requirements |
|
PSO-D&P, §6592(b) |
|
|
|
Gin Pole Masts, Stationary or Portable |
PSO-D&P, §6589 |
|
|
|
Portable Cantilever Derricks & Masts |
|
PSO-D&P, §6590 |
|
|
|
Portable Jackknife Derricks & Masts |
|
PSO-D&P, §6591 |
|
|
|
Telescoping Derricks & Masts |
|
PSO-D&P, §6591 |
|
|
Pole Steps |
|
|
|
|
PSO-D&P, §6600 |
|
|
Portable telescoping derricks or masts |
|
PSO-D&P, §6582 |
|
|
Safety belts and lanyards |
|
|
PSO-D&P, §6580 |
|
|
Stabbing hoards |
|
|
|
PSO-D&P, §6570 |
|
|
Telescoping gin pole masts |
|
|
PSO-D&P, §6584 |
|
|
Walk and pipe storage racks |
|
|
PSO-D&P, §6572 |
|
Miscellaneous provisions |
|
|
|
PSO-D&P, §6646 |
|
Overspeed (Runaway) Protection, Air and Gas
Compressors |
|
PSO-D&P, §6554(h) |
|
Overspeed (Runaway) Protection, Diesel Engine |
|
|
PSO-D&P, §6625.1 |
|
Pipe lines |
|
|
|
|
|
PSO-D&P, §6533 |
|
” ”
” |
|
|
|
See PIPELINES |
|
|
|
Blinding Procedures |
|
|
|
PSO-D&P, §6536 |
|
|
Opening Procedures |
|
|
|
PSO-D&P, §6535 |
|
Pipe Storage Racks |
|
|
|
|
PSO-D&P, §6648 |
|
Pipe Tong Requirements |
|
|
|
PSO-D&P, §6605 |
|
Pits and sumps |
|
|
|
|
PSO-D&P, §6549 |
|
Power tongs, Control mechanisms |
|
|
|
PSO-D&P, §6628 |
|
Pressure Relief Devices, Pressure Vessels &
Boilers |
|
PSO-D&P, §6551 |
|
Pressure Relief Devices, for Pumps |
|
|
|
PSO-D&P, §6634 |
|
Pressure Vessels & Boilers |
|
|
|
PSO-D&P, §6551 |
|
|
Inspection Program |
|
|
|
PSO-D&P, §6551(c) |
|
Prime Movers |
|
|
|
|
|
|
|
Definition |
|
|
|
|
PSO-D&P, §6505 |
|
|
Flywheels |
|
|
|
|
PSO-D&P, §6682 |
|
|
Internal combustion engines |
|
|
PSO-D&P, §6684 |
|
|
|
Starters for |
|
|
|
PSO-D&P, §6685 |
|
|
Power control |
|
|
|
PSO-D&P, §6681 |
|
Pull Rope, Wire |
|
|
|
|
PSO-D&P, §6640 |
|
Pumping Machinery & Equipment |
|
|
|
PSO-D&P, Article 37 |
|
|
Access to the Walking Beam |
|
|
PSO-D&P, §6632 |
|
|
Attractive Nuisance Guards: Well-Pumping Units |
|
PSO-D&P, §6633 |
|
|
Catheads |
|
|
|
|
PSO-D&P, §6642 |
|
|
|
Chain Used for Spinning Lines |
|
PSO-D&P, §6645 |
|
|
|
Lines Used on Catheads |
|
|
PSO-D&P, §6644 |
|
|
Construction & Maintenance |
|
|
PSO-D&P, §6630 |
|
|
Guarding |
|
|
|
|
PSO-D&P, §6631 |
|
|
Illumination / Lighting |
|
|
|
PSO-D&P, §6657 |
|
|
Pumps & Pump Pressure Relief Devices |
|
PSO-D&P, §6634 |
|
|
Safety Provisions & Precautions |
|
|
PSO-D&P, §6655 |
|
|
Shafts & Equipment at Oil Wells |
|
|
PSO-D&P, §6661 |
|
|
Weight Indicators for Wire Rope Hoisting Lines |
|
PSO-D&P, §6690 |
|
Shafts Pursuant to Tunnel Safety Orders |
|
|
PSO-D&P, §6661 |
|
Tanks & Reservoirs |
|
|
|
|
PSO-D&P, §6546 |
|
|
Agitation and heating of liquids |
|
|
PSO-D&P, §6544 |
|
|
Diversion and retaining walls |
|
|
PSO-D&P, §6548 |
|
|
Maintenance |
|
|
|
PSO-D&P, §6547 |
|
Tools & Equipment |
|
|
|
|
PSO-D&P, §6646 |
|
Tools, Handling Heavy Tools at Drilling Wells |
|
|
PSO-D&P, §6607 |
|
Traveling blocks |
|
|
|
|
PSO-D&P, §6638 |
|
Unloading & Loading Operations |
|
|
|
PSO-D&P, §6651 |
|
|
Platforms |
|
|
|
|
PSO-D&P, §6652 |
|
|
Vapor control, Flammable |
|
|
PSO-D&P, §6651(c) |
|
|
Wharves & Piers, at |
|
|
|
PSO-D&P, §6659 |
|
Valves |
|
|
|
|
|
PSO-D&P, §6533 |
|
Weight Indicators |
|
|
|
|
PSO-D&P, §6690 |
|
Well Identification |
|
|
|
|
PSO-D&P, §6556 |
|
Well-servicing machinery |
|
|
|
|
|
|
Applicability |
|
|
|
PSO-D&P, §6621 |
|
|
Guarding |
|
|
|
|
PSO-D&P, §6622 |
|
Well Shafts |
|
|
|
|
PSO-D&P, §6661 |
|
|
Construction and maintenance |
|
|
PSO-D&P, §6576 |
|
|
Entrances & Exits |
|
|
|
PSO-D&P, §6577 |
|
Wharves and piers |
|
|
|
|
PSO-D&P, §6659 |
|
Wire Rope Hoisting Lines |
|
|
|
PSO-D&P, §6690 |
|
|
Weight indicators |
|
|
|
PSO-D&P, §6690(a) |
|
|
|
Installation of |
|
|
PSO-D&P, §6690(b) |
|
Wire line Units |
|
|
|
|
PSO-D&P, §6688(a) |
WELL SERVICE
INDUSTRY, Explosives for |
|
|
|
GISO, Article 118 |
|
Application & Scope |
|
|
|
|
GISO, §5311 |
|
Loading or Assembling of Explosives |
|
|
|
GISO, §5312 |
|
Propellant Devices |
|
|
|
|
GISO, §5312 |
|
Storage of Explosives |
|
|
|
|
GISO, §5313 |
|
Transportation of Explosives |
|
|
|
GISO, §5313 |
WET, & Damp Locations |
|
|
|
|
|
|
Electrical Conductors / Equipment & Fixtures in |
|
|
ESO-LV, §2510.5 |
|
Electrical Conductors / Equipment Use
Prohibited when not Approved for |
ESO-LV, §2510.11(a) |
|
Protective Boots & Shoes, Wet & High
Humidity |
|
|
GISO, §4851(m) |
WET FLOORS |
|
|
|
|
|
GISO, §3273(a) |
WET SCRUBBERS, Electric, Grounding |
|
|
|
ESO-LV, §2395.45(A) |
WHARVES &
PIERS, Loading & Unloading, per PSO-D&P |
|
|
PSO-D&P, §6659 |
WHARVES &
PIERS, Loading & Unloading, per
PSO-R,T&H |
|
|
PSO-R,T&H, §6891 |
WHARVES |
|
|
|
|
|
|
|
Flammable liquids |
|
|
|
|
GISO, §5620 |
|
Marine terminal operations |
|
|
See MARINE TERMINAL
OPERATIONS |
WHEELBARROW
RUNWAYS / RAMPS |
|
|
|
CSO, §1623 |
WHEELCHAIR
LIFTS, & Stairway Chair Lifts |
|
|
See ELEVATORS, Special Access, Elevators & Lifts |
WHEELED
TRACTORS |
|
|
|
See HAULAGE VEHICLES |
|
”
” ” ” |
|
|
|
|
See also under AGRICULTURAL
SAFETY ORDERS |
WHEELS,
ABRASIVE, Use, Care, & Protection |
|
|
|
GISO, Article 21 |
|
|
Application, Scope & Definitions |
|
|
GISO, §3575 |
|
Abrasive Wheels, Portable |
|
|
|
GISO, §3583 |
|
Exposure to wheel |
|
|
|
|
GISO, §3578, Appx A, B, E |
|
Flanges, General Requirements |
|
|
|
GISO, §3579, Appx A, |
|
Flanges, Portable Abrasive Wheels |
|
|
|
GISO, §3583, Tables |
|
|
Examples (Illustrations) |
|
|
|
GISO, §3583, Appx C, D |
|
Grinding Machine Requirements, General
Requirements |
|
GISO, §3576 |
|
Guarding of |
|
|
|
|
|
GISO, §3577(b), Appx F, G |
|
Hoods, Protective |
|
|
|
|
GISO, §3577(b), (c) |
|
Illustrations |
|
|
|
|
GISO, §3583, Appx A - G |
|
Inspection of |
|
|
|
|
GISO, §3580(a) |
|
Mounting Flanges |
|
|
|
|
GISO, §3579, Appx A |
|
Mounting of |
|
|
|
|
GISO, §3580 |
|
Portable Abrasive Wheels |
|
|
|
GISO, §3583 |
|
Portable Grinders |
|
|
|
|
GISO, §3576(b) |
|
Protection Devices |
|
|
|
|
GISO, §3577 |
|
Speed |
|
|
|
|
|
|
|
|
At Safe Speeds, Per Design, Machine &
Equipment Requirement |
GISO, §3328(a) |
|
|
Check Design Speed of Wheel before Mounting |
|
GISO, §3580(a) |
|
|
Check Design Speed of Portable Abrasive Wheel
before Mounting |
GISO, §3583(f) |
|
|
Maximum Wheel Speed |
|
|
|
GISO, §3583(f), Table A-6 |
|
Stationary Grinders |
|
|
|
|
GISO, §3576(a) |
|
Storage of Wheels |
|
|
|
|
GISO, §3582 |
|
Wheel Exposure, Permissible |
|
|
|
GISO, §3578 |
|
Wheel Mounting |
|
|
|
|
GISO, §3580 |
WHEELS,
BUFFING |
|
|
|
|
|
GISO, §5152(a) |
|
Buffing Operations, Protective Equipment |
|
See GRINDING,
POLISHING & BUFFING OPERATIONS |
|
Buffing & Polishing Machines (Class A) |
|
See under METAL
WORKING MACHINES |
WHEELS, Split Rim, Servicing |
|
|
|
|
GISO, §3326 |
|
Tires, Inflation & Mounting |
|
|
|
GISO, §3325 |
|
Mounting |
|
|
|
|
|
GISO, §3326 |
|
Split-Rim Mounting, Safety Practices |
|
|
|
GISO, §3327 |
WHISTLE
SIGNALS |
|
|
|
|
|
LSSO, §6402, Appx A |
WHITENING
MACHINES, Leather & Composition Goods |
|
|
GISO, §4522 |
WILDLAND FIRE
FIGHTING |
|
|
|
|
GISO, §3410 |
”
” ” ” |
|
|
|
|
See also FIRE FIGHTERS |
|
”
” ” ” |
|
|
|
|
See also PERSONAL
PROTECTIVE EQUIPMENT, for Fire Fighters |
WINCHES, Portable |
|
|
|
|
|
GISO, §3564 |
WIND FORCE |
|
|
|
|
|
CSO, §1938, Appx B, Plate B-5 |
WINDOW
CLEANING |
|
|
|
|
|
GISO, Article 5 |
|
Accidents, Prevention, Overhead High Voltage
Lines |
|
GISO, §3282(b) |
|
Anchors & Fittings, Window Cleaning
Equipment |
|
|
GISO, §3283 |
|
Acid, Use of With Protective Equipment
Restricted |
|
GISO, §3282(j) |
|
Belts, Window Cleaner’s |
|
|
|
|
GISO, §3284(a), (b) |
|
Boatswain’s Chairs & Controlled Descent
Apparatus |
|
GISO, §3286 |
|
Building Owners’ Requirements |
|
|
|
GISO, §3282 |
|
Building Height triggers |
|
|
|
|
|
|
|
Boatswain’s Chairs, Manual, not to exceed 75',
w/ exception |
GISO, §3286(a)(1) |
|
|
Controlled Descent Apparatus (CDA), not to
exceed, 130', w/ exception |
GISO, §3286(a)(1) |
|
|
Outrigger Beams, not deployed on Buildings 130'
high, w/ exception |
GISO, §3291(d)(1) |
|
|
Roof Tie-Backs required with 3 Story or 36'
& 4 story or 48' Specified |
GISO, §3291(f)(1) |
|
Controlled Descent Apparatus, Boatswain’s Chair |
|
|
GISO, §3286 |
|
Definition |
|
|
|
|
|
GISO, §3281 |
|
Extension tools |
|
|
|
|
GISO, §3289 |
|
Fall Protection Systems & Devices |
|
|
|
GISO, §3284 |
|
General Requirements |
|
|
|
|
GISO, §3282 |
|
Harnesses, Fall Protection |
|
|
|
GISO, §3284 |
|
Building Height triggers |
|
|
|
|
|
|
|
Boatswain’s Chairs, Manual, not to exceed 75',
w/ exception |
GISO, §3286(a)(1) |
|
|
Controlled Descent Apparatus (CDA), not to
exceed, 130', w/ exception |
GISO, §3286(a)(1) |
|
|
Outrigger Beams, not deployed on Buildings 130'
high, w/ exception |
GISO, §3291(d)(1) |
|
|
Roof Tie-Backs required with 3 Story or 36'
& 4 story or 48' Specified |
GISO, §3291(f)(1) |
|
Ladder Requirements |
|
|
|
|
GISO, §3287 |
|
Operating Procedures Outline Sheet |
|
|
|
GISO, §3291, Appx A |
|
Outrigger Beams |
|
|
|
|
GISO, §3291(d) |
|
Permanent Rooftop Installations |
|
|
|
GISO, §3291 |
|
|
Required on buildings exceeding 130 feet in
height |
|
GISO, §3285(d) |
|
Personal Protective Equipment, Wearing of,
Required |
|
GISO, §3282(e), (j) |
|
Portable Sills, Prohibited Window
Equipment |
|
|
GISO, §3290 |
|
Positioning Devices |
|
|
|
|
GISO, §3284(c) |
|
Prohibited Equipment for |
|
|
|
GISO, §3290 |
|
Restraint Systems |
|
|
|
|
GISO, §3284(c) |
|
Rolling Scaffolds |
|
|
|
|
GISO, §3288 |
|
Roof tie-backs requirement |
|
|
|
GISO, §3291(f) |
|
Rooftop Window Washing Installations,
Permanent |
|
GISO, §3291 |
|
Safety Requirements, General |
|
|
|
GISO, §3282 |
|
Safety Equipment |
|
|
|
|
GISO, §3282 |
|
Scaffolds |
|
|
|
|
|
|
|
|
General safety requirements |
|
|
GISO, §3282 |
|
|
Rolling metal scaffold |
|
|
|
GISO, §3288 |
|
|
Scaffolds, Suspended |
|
|
|
GISO, §3285 |
|
|
Permanent Rooftop Installations |
|
|
GISO, §3291 |
|
|
|
Required on buildings exceeding 130 feet in
height |
GISO, §3285(d) |
|
Sills, Portable, Prohibited Equipment in Window
Washing |
|
GISO, §3290 |
|
Sills, Work from |
|
|
|
|
GISO, §3282(l), (m), (n) |
|
Tools, Extension |
|
|
|
|
GISO, §3289 |
|
Training, Safety |
|
|
|
|
GISO, §3282(f) |
|
Roof Top Installations, Permanent |
|
|
|
GISO, §3291 |
|
Window Jacks, Prohibited Equipment in Window
Washing |
|
GISO, §3290 |
WINERIES |
|
|
|
|
|
|
GISO, §5629 |
|
Fire Control, Access to Process Units |
|
|
GISO, §5629(d) |
|
Fire Fighting Equipment |
|
|
|
|
|
|
|
Portable fire extinguishment and control
equipment |
GISO, §5629(e) |
|
|
Water, Availability |
|
|
|
GISO, §5629(f) |
|
|
Special Extinguishing Equipment |
|
|
GISO, §5629(g) |
|
Fired pressure vessels |
|
|
|
|
GISO, §5629(b) |
|
Flammable and combustible liquids storage |
|
|
GISO, §5629(a) |
|
Piping systems |
|
|
|
|
GISO, §5629(b) |
|
Pressure Vessels |
|
|
|
|
GISO, §5629(b) |
|
Process units, Accessible |
|
|
|
GISO, §5629(d) |
|
Smoking Restrictions |
|
|
|
|
GISO, §5629(h) |
|
Tanks, Installation of |
|
|
|
|
GISO, §5629(a) |
|
Unfired pressure vessels |
|
|
|
|
GISO, §5629(b) |
|
Wharves |
|
|
|
|
|
GISO, §5629(c) |
WIRE DRAWING
MACHINE (Class B) |
|
|
See under METAL
WORKING MACHINES |
WIRE ROPE, Crane Inspection |
|
|
|
|
GISO, §5031(d)(2) |
WIRE ROPE, used as Guard Railing, Steel Erecting |
|
|
CSO, §1710(l)(3) |
|
Controlled Decking Zone instead of Guardrails |
|
|
CSO, §1710(n) |
|
Custody of |
|
|
|
|
|
CSO, §1710(o) |
|
Inspection of |
|
|
|
|
CSO, §1710(o) |
|
Midrail Protection |
|
|
|
|
CSO, §1710(l)(4) |
|
Net instead of Guard Railing |
|
|
|
CSO, §1710(l)(2) |
|
Wire Rope, Guard Railing |
|
|
|
CSO, §1710(l)(3) |
|
Used as Catenary Line, Fall Protection
Tie-Off |
|
|
CSO, §1710(m)(4) |
|
Used as Catenary Line |
|
|
|
|
CSO, §1670(b)(2) |
WIRE ROPE
CLIPS, Fist Grips |
|
|
|
|
|
|
Construction Hoist |
|
|
|
|
|
|
|
Guying of Hoist |
|
|
|
CSO, §1605.6(b) |
|
|
Rope Fastening, Construction Operations |
|
CSO, §1605.13 |
|
Elevators, Passenger & Freight, Prohibited
Use of |
|
|
ElevSO, §3042(j)(1)(B) |
|
Guard Railing, Used with Wire Rope as, Steel
Erection, Specification |
CSO, §1710(l)(3) |
|
General Use |
|
|
|
|
GISO, §3328 |
|
Hoisting Applications |
|
|
|
|
|
|
|
Rope Fastening, End Attachments |
|
|
GISO, §4981(c) |
|
Manufacturer's Recommendations, per TSO |
|
|
TSO, §8497(b), Tables 1 & 2 |
|
Marine Terminal, Slings, Bridles, Number &
Spacing Clips |
|
GISO, §3474(M)(1), Table MT-1 |
|
Mining Operation Conveyances, Hoisting Rope
Attachment, Number Used |
MSO, §7137 |
|
|
First-Class Hoists, Hoist Rope Attachment |
|
MSO, §7126(o) |
|
Rigging, Visual Inspections |
|
|
|
GISO, §5031(a), (b) |
|
Rope Fastening, Construction Operations |
|
|
CSO, §1605.13 |
|
Slings, Job built, Specifications of use |
|
|
GISO, §5045(d)(3) |
|
Suspended Scaffolds, Securing of Wire rope
with |
|
|
CSO, §1665(b) |
|
Tunneling Operations, Hoisting |
|
|
|
TSO, §8497(b) |
|
|
Manufacturer's Recommendations |
|
|
TSO, §8497(b), Tables 1 & 2 |
WIRE ROPE
LADDERS, Jacob's Ladder |
|
|
|
|
|
Construction Operations per CSO |
|
|
|
CSO, §1603(h) & (i) |
|
|
Definition In CSO |
|
|
|
CSO, §1504(F) |
|
Petroleum Refineries, Transportation &
Handling |
|
|
|
|
|
Approval of |
|
|
|
PSO-R,T&H, §6799.1(b) |
|
|
Definition In PSO, R,T&H |
|
|
PSO-R,T&H, §6755 |
|
|
Inspection & Load testing of, In PSO, R,T&H |
|
PSO-R,T&H, §6799.1(c) |
|
|
Use of Jacob's Ladder |
|
|
|
PSO-R,T&H, §6799.1(e) |
|
|
Use Plan |
|
|
|
|
PSO-R,T&H, §6799.1(d) |
|
Tunneling Operations per TSO, Access in Shafts
& Inclines |
|
TSO, §8494(a)(1) |
WIRE ROPE
LINES, per PSO-D&P |
|
|
|
|
PSO-D&P, §6640 |
|
Line Spoolers & Deadline Stabilizers |
|
|
|
PSO-D&P, §6688 |
|
Weight Indicators for Wire Rope Hoisting Lines |
|
|
PSO-D&P, §6690 |
WIRE ROPE
SLING, Crane Inspection |
|
|
|
GISO, §5045 |
WIRE ROPES
& SHEAVES, per TSO |
|
|
|
TSO, §8497 |
WINZES, Openings, & Raises, per MSO |
|
|
|
MSO, §7051 |
WIRING AISLES |
|
|
|
|
|
TelSO, §8602(c) |
WIRING METHOD, High Voltage |
|
|
|
|
ESO-HV, Article 7 |
|
Aboveground Wiring Method |
|
|
|
ESO-HV, §2749.1 |
|
Application / Scope |
|
|
|
|
ESO-HV, §2745.0 |
|
Braid-covered insulated conductors-open install |
|
|
ESO-HV, §2749.2 |
|
Conductor Bending Radius |
|
|
|
ESO-HV, §2748 |
|
Conductors of Different Systems |
|
|
|
ESO-HV, §2746 |
|
Covers Required |
|
|
|
|
ESO-HV, §2745.2 |
|
General Requirements |
|
|
|
|
ESO-HV, §2745.1 |
|
Grounding |
|
|
|
|
|
ESO-HV, §2750 |
|
Inserting Conductors in Raceways |
|
|
|
ESO-HV, §2747 |
|
Open Wiring (Bare) |
|
|
|
|
ESO-HV, Article 9 |
|
|
Application / Scope |
|
|
|
ESO-HV, §2755 |
|
|
Clearances over Driveways |
|
|
ESO-HV, §2758 |
|
|
Insulators |
|
|
|
|
ESO-HV, §2757 |
|
|
Spacing Between Bare Parts / Surfaces |
|
ESO-HV, §2756 |
|
Outdoor Wiring |
|
|
|
|
ESO-HV, Article 19 |
|
|
Circuit Feedback |
|
|
|
ESO-HV, §2831 |
|
|
General Requirements |
|
|
|
ESO-HV, §2823 |
|
|
Insulated Conductors |
|
|
|
ESO-HV, §2830 |
|
|
Overhead Lines |
|
|
|
ESO-HV, §2824 |
|
|
Outdoor Lighting |
|
|
|
ESO-HV, §2825 |
|
|
Raceways Above Ground |
|
|
ESO-HV, §2826 |
|
|
Raceways (or Ducts) Below Ground |
|
|
ESO-HV, §2827 |
|
|
Risers |
|
|
|
|
ESO-HV, §2828 |
|
|
Terminal Enclosures |
|
|
|
ESO-HV, §2829 |
|
Over-current Devices in Grounded
Conductors |
|
|
ESO-HV, §2751 |
|
Temporary Wiring |
|
|
|
|
ESO-HV, Article 15 |
|
|
Application / Scope |
|
|
|
ESO-HV, §2796 |
|
|
Bare Conductor Prohibition |
|
|
ESO-HV, §2799.3 |
|
|
Branch Circuits |
|
|
|
ESO-HV, §2799.2 |
|
|
Cord & Cable Protection |
|
|
|
ESO-HV, §2799.5 |
|
|
Disconnecting Means |
|
|
|
ESO-HV, §2799.4 |
|
|
Feeders |
|
|
|
|
ESO-HV, §2799.1 |
|
|
Guarding |
|
|
|
|
ESO-HV, §2798 |
|
|
Supports for Cords, & Cables |
|
|
ESO-HV, §2799.6 |
|
|
Time Limit |
|
|
|
|
ESO-HV, §2799.0 |
|
|
Use |
|
|
|
|
ESO-HV, §2797 |
WIRING METHODS, Low Voltage |
|
|
|
|
ESO-LV, Article 12 |
|
Application / Scope |
|
|
|
|
ESO-LV, §2400.1 |
|
Cable Trays |
|
|
|
|
ESO-LV, Article 15 |
|
|
Equipment Grounding Conductors |
|
|
ESO-LV, §2418.4 |
|
|
Hazardous (Classified) Locations |
|
|
ESO-LV, §2418.5 |
|
|
Industrial Establishments |
|
|
ESO-LV, §2418.3 |
|
|
Uses Not Permitted |
|
|
|
ESO-LV, §2418.6 |
|
|
Wiring Methods |
|
|
|
ESO-LV, §2418.2 |
|
Covers, J-Box, etc. Required |
|
|
|
ESO-LV, §2473.2(a) |
|
Fixture Wires |
|
|
|
|
ESO-LV, Article 50 |
|
|
General Requirements |
|
|
|
ESO-LV, §2505.2 |
|
|
Over-current Protection |
|
|
|
ESO-LV, §2505.12 |
|
|
Uses Not Permitted |
|
|
|
ESO-LV, §2505.11 |
|
|
Uses Permitted |
|
|
|
ESO-LV, §2505.10 |
|
General Requirements |
|
|
|
|
ESO-LV, §2400.2 |
|
Open Wiring on Insulators |
|
|
|
ESO-LV, Article 16 |
|
|
Conductor Supports |
|
|
|
ESO-LV, §2420.4 |
|
|
Exposed Wiring, Uses Permitted |
|
|
ESO-LV, §2420.3 |
|
|
Flexible Nonmetallic Tubing |
|
|
ESO-LV, §2420.5 |
|
|
Penetrations of Walls, Floors, etc. |
|
|
ESO-LV, §2420.6 |
|
|
Protection from Physical Damage |
|
|
ESO-LV, §2420.7 |
|
Outdoor Wiring |
|
|
|
|
ESO-LV, Article 8 |
|
|
Application / Scope |
|
|
|
ESO-LV, §2375.1 |
|
|
Clearance from Buildings |
|
|
ESO-LV, §2375.19 |
|
|
Clearance from Ground |
|
|
|
ESO-LV, §2375.18 |
|
|
Conductors on Poles |
|
|
|
ESO-LV, §2375.7 |
|
|
Location of Outdoor Lamps |
|
|
ESO-LV, §2375.25 |
|
Temporary Wiring |
|
|
|
|
ESO-LV, Article 13 |
|
|
Application / Scope |
|
|
|
ESO-LV, §2405.1 |
|
|
General Requirements |
|
|
|
ESO-LV, §2405.2 |
|
|
GFCI Protection, Construction Sites |
|
|
ESO-LV, §2405.4 |
|
|
Temporary Poles |
|
|
|
ESO-LV, §2405.3 |
WIRING, Hard Wiring Required |
|
|
|
|
ESO-LV, §2500.8 |
WIRING, Exposed, Use of |
|
|
|
|
ESO-LV, §2420.3(a) |
WIRING, Temporary |
|
|
|
|
|
ESO-LV, §2405.1 |
WIRING, Unsafe |
|
|
|
|
|
ESO-LV, §2340.1 |
WOBBLE SAWS, Woodworking |
|
|
|
|
GISO, §4323 |
WOOD CHIPPERS |
|
|
|
|
|
GISO, §6364 |
WOOD DUST, Airborne Contaminant, Exposure limit |
|
|
GISO, §5155, & Appx A |
|
Listed, Permissible Exposure Limits |
|
|
|
GISO, §5155, Table AC-1 |
WOOD FRAMING, Structural |
|
|
|
|
CSO, §1716.1 |
WOODEN POLE
SCAFFOLDS, Heavy-Trade |
|
|
|
CSO, §1641 |
WOODEN POLE
SCAFFOLDS, Light-Duty |
|
|
|
CSO, §1640 |
”
” ” ” ” ” ” |
|
|
See also SCAFFOLDING |
|
WOOD LADDERS |
|
|
|
|
See also LADDERS |
GISO, §3276 |
WOOD SHAPER
& SIMILAR EQUIPMENT, Woodworking |
|
|
GISO, §4318.1 |
WOOD, Structural Frame Construction |
|
|
|
CSO, §1716.2 |
WOOD, Structural Framing Systems |
|
|
|
CSO, §1716.1 |
WOODWORKING
MACHINES & EQUIPMENT |
|
|
|
GISO, Article 59 |
|
|
Definitions |
|
|
|
|
GISO, §4297 |
|
|
General Requirements |
|
|
|
GISO, §4296 |
|
Automatic lathes |
|
|
|
|
GISO, §4319 |
|
Band Knives |
|
|
|
|
GISO, §4310 |
|
Band Saws |
|
|
|
|
|
GISO, §4310 |
|
Belt Sanders (Class B) |
|
|
|
|
GISO, §4312 |
|
Boring Machines |
|
|
|
|
GISO, §4316 |
|
Box Shook Cut-Off Saws (California Cut-off
Saws) |
|
|
GISO, §4304 |
|
Brush chippers |
|
|
|
|
GISO, §4299 |
|
California Cut-off Saws |
|
|
|
|
GISO, §4304 |
|
Chippers, Brush & Slash |
|
|
|
|
GISO, §4299 |
|
Circular Knives & Crosscut Saws (Class B) |
|
|
GISO, §4302 |
|
Circular Ripsaws, Manual Feed (Class B) |
|
|
GISO, §4300 |
|
Circular Ripsaws, Self Feeding (Class B) |
|
|
GISO, §4301 |
|
Circular Saw Blades & Knives, Speed of |
|
|
GISO, §4322 |
|
Circular Saws, Portable Power Driven Hand Saw |
|
|
GISO, §4307 |
|
Combination Woodworking Machines |
|
|
GISO, §4320 |
|
Construction of Equipment |
|
|
|
GISO, §4296 |
|
Cordwood Saws & Similar (Class B) |
|
|
|
GISO, §4303 |
|
Cracked Saws |
|
|
|
|
GISO, §4321 |
|
Crosscut Saws & Circular Knives (Class B) |
|
|
GISO, §4302 |
|
Cut-off saws |
|
|
|
|
|
|
|
Box Shook Cut-Off Saws |
|
|
GISO, §4304 |
|
|
California Cut-off Saws |
|
|
|
GISO, §4304 |
|
|
Circular Saws, Portable Power Driven Hand Saw |
|
GISO, §4307 |
|
|
Sliding cut-off saws |
|
|
|
GISO, §4305 |
|
|
Swing Cut-Off Saws |
|
|
|
GISO, §4305 |
|
Definitions |
|
|
|
|
|
GISO, §4297 |
|
Disc Sanders |
|
|
|
|
GISO, §4313 |
|
Drum Sander |
|
|
|
|
GISO, §4314 |
|
Dust Collection Systems |
|
|
|
|
GISO, §4324 |
|
Elbow Sanders |
|
|
|
|
GISO, §4315 |
|
Exhaust systems |
|
|
|
|
GISO, §4324 |
|
Guards |
|
|
|
|
|
GISO, §4296 |
|
Hand fed planers |
|
|
|
|
GISO, §4311 |
|
Hog Mills |
|
|
|
|
|
GISO, §4298 |
|
Hoods |
|
|
|
|
|
GISO, §4296 |
|
Horizontal Pull Saws (Radial Arm Saws) |
|
|
GISO, §4309 |
|
Inverted Swing Cut-Off Saws |
|
|
|
GISO, §4306 |
|
Jointers |
|
|
|
|
|
GISO, §4311 |
|
Jump Saws |
|
|
|
|
|
GISO, §4306 |
|
Lathes |
|
|
|
|
|
|
|
|
Automatic |
|
|
|
|
GISO, §4319 |
|
|
Rotating Knife (Automatic) |
|
|
GISO, §4319 |
|
|
Shoe Last Lathes |
|
|
|
GISO, §4319 |
|
|
Spoke Lathes |
|
|
|
GISO, §4319 |
|
Matching Machines |
|
|
|
|
GISO, §4318 |
|
Miter Saws |
|
|
|
|
|
GISO, §4307.1 |
|
Mortising Machines |
|
|
|
|
GISO, §4316 |
|
Molding Machines |
|
|
|
|
GISO, §4318 |
|
Planers, Hand Fed |
|
|
|
|
GISO, §4311 |
|
Planing Machines |
|
|
|
|
GISO, §4318 |
|
Portable Power Driven Circular Hand Saws |
|
|
GISO, §4307 |
|
|
Base Plate |
|
|
|
|
GISO, §4307(a) |
|
|
Hinged Guard |
|
|
|
GISO, §4307(b) |
|
|
Lower Half |
|
|
|
|
GISO, §4307(b) |
|
|
Shoe |
|
|
|
|
GISO, §4307(a) |
|
|
Teeth |
|
|
|
|
GISO, §4307(a) |
|
|
Telescopic Guard |
|
|
|
GISO, §4307(b) |
|
|
Upper Guard |
|
|
|
GISO, §4307(a) |
|
Radial Arm Saws |
|
|
|
|
GISO, §4309 |
|
Rotating Knife Type Lathes (Automatic) |
|
|
GISO, §4319 |
|
Sanders |
|
|
|
|
|
|
|
|
Belt Sanders (Class B) |
|
|
|
GISO, §4312 |
|
|
Disc Sanders |
|
|
|
GISO, §4313 |
|
|
Drum Sander |
|
|
|
GISO, §4314 |
|
|
Elbow Sanders |
|
|
|
GISO, §4315 |
|
Saws, Cracked |
|
|
|
|
GISO, §4321 |
|
Saws, Wobble |
|
|
|
|
GISO, §4323 |
|
Shapers |
|
|
|
|
|
GISO, §4318.1 |
|
Slash chippers |
|
|
|
|
GISO, §4299 |
|
Sliding cut-off saws |
|
|
|
|
GISO, §4305 |
|
Speed of blades |
|
|
|
|
GISO, §4322 |
|
Spoke Lathes |
|
|
|
|
GISO, §4319 |
|
Shoe Last Lathes |
|
|
|
|
GISO, §4319 |
|
Sticking Machines |
|
|
|
|
GISO, §4318 |
|
Swing Cut-Off Saws |
|
|
|
|
GISO, §4305 |
|
Table Saws, Manual Feed (Class B) |
|
|
|
GISO, §4300.1 |
|
Tenoning Machines |
|
|
|
|
GISO, §4317 |
|
Tobacco Machines |
|
|
|
See FOOD & TOBACCO
MACHINES |
|
Underhung Swing Cut-off Saws |
|
|
|
GISO, §4306 |
|
Underslung Saws |
|
|
|
|
GISO, §4306 |
|
Wobble saws, Prohibition |
|
|
|
GISO, §4323 |
|
Wood Shapers |
|
|
|
|
GISO, §4318.1 |
WOODWORKING
MACHINES, Exhaust Systems |
|
|
GISO, §4324 |
WORK AREA, General |
|
|
|
|
|
GISO, §3273 |
|
Clean, Sanitary & Orderly |
|
|
|
GISO, §3362(a) |
|
Dry Floor, Free form Water, Grease, Oil |
|
|
GISO, §3273(a) |
|
|
Alternative Protection, Wet Processes |
|
GISO, §3273(a) |
|
Lighting, Illumination of |
|
|
|
GISO, §3317 |
|
Work sites subject to |
|
|
|
|
PSO-R,T&H, §6894 |
WORK BENCHES, Lighting |
|
|
|
|
GISO, §3317 |
WORKER
PROTECTION, Safe Machinery & Equipment |
|
|
GISO, §3328(a) |
WORKING ALONE |
|
|
|
|
|
GISO, §3328(a) |
|
Worksites Subject to Ship Yard Standards |
|
|
SSO, §8397.6 |
WORKMAN LIKE
MANNER, Execution of Work, Quality |
|
|
ESO-LV, §2340.12 |
WORKING AREAS |
|
|
|
|
|
GISO, §3273 |
|
Catwalks, Exemption |
|
|
|
|
GISO, §3273(d) |
|
Catwalks, Size |
|
|
|
|
GISO, §3273(d) |
|
Dangerous Depressions, Obstructions &
Debris |
|
|
GISO, §3273(b) |
|
Ditches, Pits, Excavations And Surfaces In Poor
Repair, Guarding |
GISO, §3273(l) |
|
Excavations, Guarding Of |
|
|
|
GISO, §3273(l) |
|
Falling Objects, Protection From |
|
|
|
GISO, §3273(f) |
|
Floors, Maintained & In Good Repair |
|
|
|
GISO, §3273(a) |
|
Grease, Free Of, Floors And Platforms |
|
|
GISO, §3273(a) |
|
Headroom, Elevated Working Levels, Platforms,
Ramps & Runways |
GISO, §3273(c) |
|
|
When Installed Along Inclined |
|
|
GISO, §3273(d) |
|
Impaired Clearances, Posted, Guarding |
|
|
GISO, §3273(m) |
|
Lighting of Working Area |
|
|
|
GISO, §3317 |
|
|
Skylight used as Lighting |
|
|
GISO, §3317(c) |
|
Lower Clearances, Impaired Clearances Posted,
Guarding, |
|
GISO, §3273(m) |
|
Lowering Objects |
|
|
|
|
GISO, §3273(f) |
|
Machines Or Equipment Shall Be Located And
Guarded, |
|
GISO, §3273(i) |
|
Maintenance Of Prime Movers, Machines, Or
Equipment |
|
GISO, §3273(g) |
|
Material Storage Areas, Maintenance Requirement |
|
GISO, §3273(b) |
|
Mats, Grates, Cleats, On Floors And
Platforms |
|
|
GISO, §3273(a) |
|
Obstructions, Floors And Platforms |
|
|
|
GISO, §3273(a) |
|
Obstructions, Free From |
|
|
|
|
GISO, §3273(b) |
|
Oil, Free Of, Floors & Platforms, Free
Of |
|
|
GISO, §3273(a) |
|
Padding Obstruction |
|
|
|
|
GISO, §3273(c) |
|
Permanent Floors And Platforms |
|
|
|
GISO, §3273(a) |
|
Pits, Guarding |
|
|
|
|
GISO, §3273(l) |
|
Pits, Machinery Or Equipment |
|
|
|
GISO, §3273(j) |
|
Prime Movers, Machines, And Equipment,
Placement & Guarding |
GISO, §3273(h) |
|
Posted & Guarding, Impaired Clearances |
|
|
GISO, §3273(m) |
|
Protection from Falling Objects |
|
|
|
GISO, §3273(e) |
|
Rail Car, Shop Transfer Car, Load
Clearances |
|
|
GISO, §3273(k) |
|
Ramp standards |
|
|
|
|
GISO, §3273(c) |
|
Reduced clearances, posted, guarding, |
|
|
GISO, §3273(m) |
|
Roadways, free of dangerous depressions,
obstructions |
|
GISO, §3273(b) |
|
Roadways, maintenance Requirement |
|
|
|
GISO, §3273(b) |
|
Roadways, Permanent |
|
|
|
|
GISO, §3273(b) |
|
Shop transfer car, Equipment carriage operating
on rails, load clearances, |
GISO, §3273(k) |
|
Sign Posting & Guarding of Impaired
Clearances |
|
|
GISO, §3273(m) |
|
Surfaces in poor repair, Guarding of |
|
|
|
GISO, §3273(l) |
|
Walkways, free of dangerous depressions,
obstructions |
|
GISO, §3273(b) |
|
Warning of Obstruction |
|
|
|
|
GISO, §3273(c) |
|
Water, free of, floors and platforms |
|
|
|
GISO, §3273(a) |
|
Wet Floors |
|
|
|
|
|
GISO, §3273(a) |
WORKING NEAR
HIGH VOLTAGE |
|
|
|
ESO-HV, §2946(a) |
WORKING ON
EXPOSED ENERGIZED PARTS, High Voltage, per ESO |
|
ESO-HV, §2945, Appx A |
|
General requirements |
|
|
|
|
ESO-HV, §2945, Appx A |
|
|
Definitions |
|
|
|
|
ESO-HV, §2945, Appx A |
|
|
Installations energized at 50 to 300 volts |
|
ESO-HV, §2945, Appx A |
|
|
Exposed energized parts over 600 volts AC |
|
ESO-HV, §2945, Appx A |
|
|
Types of exposures |
|
|
|
ESO-HV, §2945, Appx A |
|
Minimum Approach Distances |
|
|
|
ESO-HV, §2945, Appx A |
|
Determining Minimum Approach Distances |
|
|
ESO-HV, §2945, Appx A |
|
Minimum Approach-Distance Tables |
|
|
|
ESO-HV, §2945, Appx A |
WORK OVER OR
NEAR WATER |
|
|
|
|
|
|
Construction Operations. Per CSO |
|
|
|
CSO, §1602 |
|
Electrical Work, per ESO |
|
|
|
|
ESO-HV, §2940.5 |
|
General Industry , Per GISO |
|
|
|
GISO, §4405 |
WORKING
PLATFORMS, & Scaffolding |
|
|
|
MSO, §7048 |
WORKING
SURFACES, Guardrails / Toeboards, Exception |
|
|
TelSO, §8602(b)(1) |
WORKING
WAREHOUSES |
|
|
|
|
GISO, §3241.1 |
WORKPLACE HAZARD ASSESSMENT,
under IIPP |
|
|
GISO, §3203(a)(4) |
WORKPLACE HAZARD ASSESSMENT,
PPE Selection |
|
|
GISO, §3380(f) |
|
Employer's Written Certification |
|
|
|
GISO, §3380(f)(2) |
|
Examples of Assessment Procedures |
|
|
|
GISO, §3380, Appx A |
|
Personal Protective Devices, Equipment
Selection |
|
|
GISO, §3380(f) |
|
|
Communicate to Effected Employee |
|
|
GISO, §3380(f)(1)(B) |
|
|
Damaged/Defective PPE |
|
|
|
GISO, §3380(f)(3) |
|
|
Properly Fitted PPE |
|
|
|
GISO, §3380(f)(1)(C) |
|
|
Select PPE |
|
|
|
|
GISO, §3380(f)(1)(A) |
|
|
Training |
|
|
|
|
GISO, §3380(f)(4) |
WORK
PLATFORMS, ELEVATING, & AERIAL DEVICES |
|
|
|
|
|
Application |
|
|
|
GISO, §3636 |
|
|
Definitions |
|
|
|
|
GISO, §3637 |
|
Control Devices, Elevating Work Platforms |
|
|
GISO, §3642(d) |
|
Design / Factors of Safety |
|
|
|
GISO, §3639 |
|
Elevated Work Platform Equipment |
|
|
|
GISO, §3642 |
|
Emergency Stopping Device |
|
|
|
GISO, §3642(e) |
|
Equipment Requirement, Elevating Work Platforms |
|
GISO, §3642 |
|
Factors of Safety of Design |
|
|
|
GISO, §3639 |
|
Fall Protection, Elevating Work Platforms |
|
|
GISO, §3642(a) |
|
General Requirements |
|
|
|
|
GISO, §3638 |
|
Guardrail, Elevating Work Platforms |
|
|
|
GISO, §3642(a) |
|
Guarding of Moving Parts |
|
|
|
GISO, §3643 |
|
High-Voltage Operations, used during |
|
|
ESO-HV, §2940.7(b) |
|
|
Defined |
|
|
|
|
ESO-HV, §2700 |
|
Inclined Surfaces, Stability on |
|
|
|
GISO, §3645 |
|
Inspection |
|
|
|
|
|
GISO, §3640 |
|
|
Records of |
|
|
|
|
GISO, §3640(d)(1) |
|
Load limits |
|
|
|
|
|
GISO, §3648(f) |
|
Maintenance |
|
|
|
|
GISO, §3640 |
|
Manual, Instructions |
|
|
|
|
GISO, §3638(a) |
|
Mobile Work Platforms |
|
|
|
|
GISO, §3626 |
|
Moving parts, Guarding of |
|
|
|
GISO, §3643 |
|
Operating Instructions, Aerial Devices |
|
|
GISO, §3648 |
|
Operating Instructions, Elevating Work
Platforms |
|
|
GISO, §3646 |
|
Orchard Manlifts (Pruning Towers) |
|
|
|
GISO, §3641 |
|
Platforms, Pin-On |
|
|
|
|
GISO, §3647 |
|
Pruning Towers (Orchard Manlifts) |
|
|
|
GISO, §3641 |
|
Repair |
|
|
|
|
|
GISO, §3640 |
|
|
Records of |
|
|
|
|
GISO, §3640(d)(2) |
|
Stability on Inclined Surfaces |
|
|
|
GISO, §3645 |
|
Surface, Level & w/out Hazardous
Irregularities |
|
|
GISO, §3646(a)(3) |
|
Wood framing systems |
|
|
|
|
CSO, §1716.1 |
|
Work Platforms, Mobile |
|
|
|
|
GISO, §3626 |
WORK SPACE, Construction |
|
|
|
|
|
|
Safety Survey, Prior to Presence of Employee |
|
|
CSO, §1511(b) |
|
Unsafe Place of Employment Prohibited |
|
|
CSO, §1511(a) |
WORK SPACE, Per ESO |
|
|
|
|
|
|
Access to |
|
|
|
|
|
ESO-HV, §2931 |
|
About Electrical Equipment |
|
|
|
ESO-LV, §2340.16 |
|
Electrical railway facilities |
|
|
|
ESO-HV, §2945 |
|
Electrical utility facilities |
|
|
|
|
ESO-HV, §2945 |
|
Entrance |
|
|
|
|
|
ESO-HV, §2931 |
|
Substations, at |
|
|
|
|
ESO-LV, §2553.64 |
|
Illumination |
|
|
|
|
|
ESO-HV, §2933 |
|
Minimum depth around equipment |
|
|
|
ESO-HV, §2932 |
|
Outdoor enclosures |
|
|
|
|
ESO-HV, §2935 |
|
Passageway, work space not to be used as when
energized parts exposed |
ESO-HV, §2936 |
|
Suitable space |
|
|
|
|
ESO-HV, §2932 |
|
Unguarded live parts, elevation |
|
|
|
ESO-HV, §2934 |
WORK SPACES, per MSO |
|
|
|
|
|
|
For Machine Operators, Underground |
|
|
MSO, §7000 |
WORK SPACES, per TelSO |
|
|
|
|
|
|
Aisles, Requirements |
|
|
|
|
TelSO, §8602(c) |
|
Safe Work Spaces Requirement |
|
|
|
TelSO, §8602(g) |
WORKSTANDS, Portable or Fixed,
Guardrail Exception |
|
|
GISO, §3210(b), Exception (4) |
WORK STOPPAGE
REQUIREMENTS, per GISO |
|
|
|
|
|
Avalanche Blasting, During lightning storm |
|
|
GISO, §5245 |
WORK STOPPAGE
REQUIREMENTS, per MSO |
|
|
|
|
|
Presence of Air Contaminants |
|
|
|
MSO, §7102(c) |
WORK STOPPAGE
REQUIREMENTS, per TelSO |
|
|
|
|
Inclement Weather Conditions |
|
|
|
TelSO, §8602(i) |
WORK STOPPAGE
REQUIREMENTS, per TSO |
|
|
|
|
|
Presence of Air Contaminants |
|
|
|
TSO, §8424(c) |
|
Fatality |
|
|
|
|
|
TSO, §8420(c) |
WRAPPERS &
SLICERS, Food Service |
|
|
|
GISO, §4548 |
WRECKING /
DEMOLITION, per CSO |
|
|
|
|
|
Asbestos, assessment requirement |
|
|
|
CSO, §1735(c) |
|
|
Exposure
to |
|
|
See ASBESTOS, per CSO |
|
|
Barricades |
|
|
|
|
|
CSO, §1736(f) |
|
Bracing, Wall Stability |
|
|
|
|
CSO, §1735(m) |
|
Building Demolition Requirements |
|
|
|
CSO, §1735 |
|
Chutes for waste disposal |
|
|
|
CSO, §1736,(i) |
|
|
Enclosed, when Loading Trucks |
|
|
CSO, §1736,(b) |
|
|
|
Design |
|
|
|
CSO, §1736,(c) |
|
|
Guard Railing of Chute Openings |
|
|
CSO, §1736(d) |
|
Cranes used in |
|
|
|
|
GISO, §4941 |
|
Debris, disposal of |
|
|
|
|
CSO, §1736 |
|
Demolishing Buildings |
|
|
|
CSO, §1735 |
|
Demolition Sequence |
|
|
|
|
CSO, §1735(f) |
|
Displaced materials removal from building |
|
|
CSO, §1735(e) |
|
|
As work Progresses |
|
|
|
CSO, §1736(g) |
|
Disposal of Waste Material |
|
|
|
CSO, §1736 |
|
|
Barricading, When dropping debris without
chute |
CSO, §1736(f) |
|
|
Removal as work proceeds |
|
|
CSO, §1736(g) |
|
|
Chute bumper/Toe Board, design and construction |
CSO, §1736(i) |
|
|
Chute design and use |
|
|
|
CSO, §1736(b), (c) |
|
|
|
Clogged Chute Clearing |
|
|
CSO, §1736(c) |
|
|
Chute openings, open spaces |
|
|
CSO, §1736(d) |
|
|
Debris removal without the use of a chute |
|
CSO, §1736(f) |
|
|
Guarding/Barricading Chute Discharge End |
|
CSO, §1736(e) |
|
|
Guarding Chute openings, open spaces |
|
CSO, §1736(d) |
|
|
Flammable materials, storage |
|
|
CSO, §1736(h) |
|
|
Waste material removal |
|
|
|
CSO, §1736(g) |
|
Dust control |
|
|
|
|
CSO, §1735(t) |
|
Elevators for hoisting employees |
|
|
|
CSO, §1735(r) |
|
Engineering survey before start of Work |
|
|
CSO, §1734(b) |
|
Fall Protection |
|
|
|
|
CSO, §1735(k) |
|
Floor openings, guarding when using mechanical
equipment |
|
CSO, §1735(v) |
|
Falling materials, protection from |
|
|
|
CSO, §1735(j) |
|
Beams planked over |
|
|
|
|
CSO, §1735(s) |
|
Floor Openings Guarding for Mechanical
Equipment |
|
CSO, §1735(v) |
|
Floor Stability |
|
|
|
|
CSO, §1735(f) |
|
Floor structure safe for mechanical equipment |
|
|
CSO, §1735(u) |
|
Floor Structure Safe for Mechanical Equipment |
|
|
CSO, §1735(u) |
|
Glazing, Glass Wall Openings |
|
|
|
CSO, §1735(l) |
|
Hazardous, Flammable, Explosive Materials |
|
|
CSO, §1735(b) |
|
|
Disposal of |
|
|
|
|
CSO, §1736(h) |
|
Inspections |
|
|
|
|
|
|
|
|
Before Start of Work |
|
|
|
CSO, §1734(b) |
|
|
Continuing during Demolition |
|
|
CSO, §1735(d)(4) |
|
Ladder requirement |
|
|
|
|
CSO, §1735(p)(2) |
|
Walkways or ladders shall be provided |
|
|
CSO, §1735(p)(3) |
|
Lighting requirement |
|
|
|
|
CSO, §1735(q) |
|
Permit Requirement |
|
|
|
See Cal/OSHA, 341(d)(3) |
|
|
Piping Dismantling, Pressure Relieving before |
|
|
GISO, §3329(d) |
|
Planking, Floor Substitute |
|
|
|
CSO, §1735(o) |
|
Safety Nets or Planking Required |
|
|
|
CSO, §1735(s) |
|
Salvage of materials, prohibition |
|
|
|
CSO, §1735(w) |
|
Stability of Structure |
|
|
|
|
CSO, §1735(d) |
|
Stairways to be clear for use |
|
|
|
CSO, §1735(p) |
|
Steel Construction |
|
|
|
|
CSO, §1735(n) |
|
Supervision Requirement for Demolition |
|
|
CSO, §1734(a) |
|
Survey of Structure / Building |
|
|
|
CSO, §1734(b) |
|
Utility companies notification |
|
|
|
CSO, §1735(a) |
|
Walking across Joists, Beams, Girders
Prohibited |
|
|
CSO, §1735(i) |
|
Walkways |
|
|
|
|
|
CSO, §1735(h) |
|
Walkways or ladders shall be provided |
|
|
CSO, §1735(p)(3) |
|
Wall Stability |
|
|
|
|
CSO, §1735(m) |
|
Waste disposal |
|
|
|
|
CSO, §1736 |
|
|
Barricading, When dropping debris without
chute |
CSO, §1736(f) |
|
|
Removal as work proceeds |
|
|
CSO, §1736(g) |
|
|
Chute bumper/Toe Board, design and construction |
CSO, §1736(i) |
|
|
Chute design and use |
|
|
|
CSO, §1736(b), (c) |
|
|
|
Clogged Chute Clearing |
|
|
CSO, §1736(c) |
|
|
Chute openings, open spaces |
|
|
CSO, §1736(d) |
|
|
Debris removal without the use of a chute |
|
CSO, §1736(f) |
|
|
Guarding/Barricading Chute Discharge End |
|
CSO, §1736(e) |
|
|
Guarding Chute openings, open spaces |
|
CSO, §1736(d) |
|
|
Flammable materials, storage |
|
|
CSO, §1736(h) |
|
|
Waste material removal |
|
|
|
CSO, §1736(g) |
WRITTEN PLANS
& PROGRAMS, General |
|
|
|
|
|
Aerosol Transmissible Diseases, Exposure
Control Plan |
|
GISO, §5199(d) |
|
Emergency Action Plan |
|
|
|
|
GISO, §3220(a) |
|
Fire Prevention Plan |
|
|
|
|
GISO, §3221 (a) |
|
Hazard Communication Program |
|
|
|
GISO, §5194(e) |
|
Hazard Program |
|
|
|
|
GISO, §5194(e)(1) |
|
Injury & Illness Prevention Program |
|
|
|
GISO, §3203 |
|
Respiratory Protection Program |
|
|
|
GISO, §5144(f)(1) |
|
Workplace Violence Prevention Plan, Per GISO |
|
|
GISO, §3342(c) |
|
Hotel Housekeeping Musculoskeletal injury
prevention program |
GISO, §3345(c) |
|
|
|
|
|
|
|
|