D             List of Acronyms
DADO BLADE, Wobble Saw, Prohibition       GISO, §4323
DAILY INSPECTIONS, before start of Shift         
  Excavations         CSO, §1541(k)(1)
  Forklift           GISO, §3664(a)(7)
  Supervisor / Employer Conducted       CSO, §1511
  Haulage Vehicle         CSO, §1597(j) 
  Scaffold Planking         CSO, §1637(h)
DAMAGE PREVENTION, Electrical Equipment       ESO-LV, §2340.26
DAMAGED / BROKEN, Cargo          GISO, §3339
DAMAGED / DEFECTIVE, Personal Protective Equipment, PPE     GISO, §3380(f)(3)
DAMS, Water Retaining           MSO, §7175
  Underground Protection from Water        MSO, §7176
DAMP & WET LOCATIONS, Electrical Fixtures in       ESO-LV, §2510.5
  Deteriorating Conditions         ESO-LV, §2340.11(a)(1)
DANGEROUS EXCAVATIONS, at Underground Mines     MSO, §7178
  Access to Unattended Mine Opening limited, Guarded, Covered   MSO, §7178(a)
    Dangerous, inactive or abandoned mine openings, guarded MSO, §7178(c)
  Accumulation of Water         MSO, §7178(d)
  Dangerous Underground Excavations, Ground Control    
    Back Filled or Controlled       MSO, §6987
  Surface Excavations, Dangerous, Covering up     MSO, §7178(b)
DANGEROUS EXPOSURE PREVENTION       PSO-R,T&H, Article 6
  Allaying Dust, Fumes, Mists, Vapor & Gases     PSO-R,T&H, §6788
  Change Room, pursuant to Article 10, GISO     PSO-R,T&H, §6787
  Clothing           PSO-R,T&H, §6786
DANGEROUS OBSTRUCTIONS, Walkways        GISO, §3273(b)
DATA PROCESSING SYSTEMS          
  Disconnecting means         ESO-LV, §2565.3
  Interconnecting cables         ESO-LV, §2565.2(b)
    Under Raised Floors       ESO-LV, §2565.2(c)
  Supply circuits         ESO-LV, §2565.2(a)
DATE PALMS, Operations         See also AGRICULTURAL SAFETY ORDERS (AgSO) 
  Competent person, Designer of Saddles     GISO, §3458(c) 
  Date palm saddles          
    Design         GISO, §3458(c)
    Use of         GISO, §3458(c)(1)
      Lanyards       GISO, §3458(c)(2)
      Anchorage prohibitions     GISO, §3458(c)(3)
  Fall Protection           
    Inspection of Equipment        GISO, §3458(f)
    Trigger Height, >7 ˝’            GISO, §3458(a) 
    Positioning devices systems permitted for fall protection, conditions GISO, §3458(d)
      Lanyards, placement     GISO, §3458(d)(1)
      Lanyards, maximum length, rigging   GISO, §3458(d)(2)
      Dead, decayed, damaged fronds   GISO, §3458(d)(3)
      When changing work positions   GISO, §3458(d)(4)
  Job briefing          GISO, §3458(e)
  Inspection of fall protection equipment     GISO, §3458(f)
  Ladders Attached to Date Palms       GISO, §3458.1 
  Lanyards, Construction of       GISO, §3458(b) 
  Qualified person          
    Conduct Job Briefing        GISO, §3458(e)
    Inspection of Fall Protection Equipment    GISO, §3458(f)
  Positioning device, used as Fall Protection      GISO, §3458(d) 
    Lanyards, placement       GISO, §3458(d)(1) 
    Lanyards, maximum length, rigging     GISO, §3458(d)(2)
    Dead, decayed, damaged fronds     GISO, §3458(d)(3)
    When changing work positions     GISO, §3458(d)(4)
  Saddles            
    Design         GISO, §3458(c)
    Use of          GISO, §3458(c)(1) 
    Lanyards, placement       GISO, §3458(c)(2)
    Dead, decayed, damaged fronds     GISO, §3458(c)(3)
DBCP, Exposure to            GISO, §5212
DDT, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DEADMAN’S SWITCH, Momentary Contact Device      
  Kill Switch         See KILL SWITCH   
  Portable Power Drives, Post Hole Digger, Pipe Threader /Cutter   GISO, §4086
  Portable Tools         GISO, §3557
DEADLINE STABILIZERS & Line Spoolers       PSO-D&P, §6688
DEBRIS, cleaning up at Construction Sites, Housekeeping     CSO, §1513
DECABORANE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DECKING/DECKS, per PSO-D&P          
  Decking at Derrick Platforms       PSO-P&D, §6560(e), (f), (g), 
DECKING/DECKS, per CSO          
  Controlled Decking Zone (CDZ), Structural Steel Erection,    CSO, §1710(n) 
    Shear Connectors, Installation within CDZ Prohibited CSO, §1710(e) 
  Flooring, Fully Decked Below Work Area, Multi-floor Buildings   CSO, §1709(c)
  Flooring, Temporary, Multi-floor Buildings     CSO, §1635(b)
  Pump Jack Scaffolds, fully Decked       CSO, §1655
  Stairways to uppermost decked floor, of Steel Framed Buildings   CSO, §1629(b)
DECKING/DECKS, per LSSO          
  Flooring for Carriage, where Employees Ride     LSSO, §6348(a)
  Decks, at Sawmills         LSSO, §6345(c)-(j)
  Deck surfaces, cleaning, at Sawmills       LSSO, §6345(i)
  Landings, Helicopter Yarding Operations     LSSO, §6323(a)
  Log Decks, per LSSO         LSSO, §6332
  Steel Decks of Machinery, Safety Tread or other Non-slip installed on  LSSO, §6333(l)
  Trucks, Frame Flooring Requirement       LSSO, §6333(l)
DECKS, SHIP, per SSO            
  Battery Deck, Storage, Submarines       SSO, §8386(a), (b)
  Deck Machinery, Precautions       SSO, §8376
  Deck Openings, & Open Decks       SSO, §8374
  Internal Combustion Engines operated below deck, Precautions   SSO, §8384(c)
  Forges operated under raised decks, Prohibition     SSO, §8375
  Access to Ship's Decks         SSO, §8371(e), (f)
DECOMPRESSION CHAMBERS           
  Commercial diving operations, post dive procedures   GISO, §6062(a)
    Decompression chamber, location     GISO, §6062(a)(2)
    Recompression  capability     GISO, §6062(b)
  Equipment Requirements       GISO, §6063
  Pressurized worksites       See Also PRESSURIZED WORKSITE OPERATION
    Medical Decompression chamber     GISO, §6120(b)
    Special Decompression Chamber     GISO, §6095
      Definition       GISO, §6074
DECORATIONS, Fire Safety         GISO, §3217 
DE-ENERGIZING EQUIPMENT, per CSO        
  Blocking / Locking, Repair of Haulage & Earth Moving Equipment CSO, §1595(a) 
  Blocking / Locking, Repair of Dump Trucks     CSO, §1595(b) 
DE-ENERGIZING EQUIPMENT, per ESO       ESO-LV, §2320.4
  Re-energizing         ESO-LV, §2320.5
  Testing to Ensure         ESO-LV, §2320.3
  Work on, Conditions prerequisite to       ESO-LV, §2320.4
DE-ENERGIZING EQUIPMENT, per GISO        
  Control of Hazardous Energy        GISO, §3314(c)
DEFECTIVE             
  Equipment / Machinery         GISO, §3328(c)
  Ladders            GISO, §3276(e)(3)
  Parts           GISO, §3328(c)
DEFICIENCY, OXYGEN, Employee Exposure To       GISO, §5149
DEGREASING, Operations, Ventilation and PPE Requirements   GISO, §5154 
DE-ICING & SNOW MELTING EQUIPMENT, Fixed     ESO-LV, Article 54
  Application / Scope         ESO-LV, §2526.1
  Disconnecting Means         ESO-LV, §2526.50
DELNAV, Airborne Contaminants, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DEMETON, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DEMOLITION, per CSO          
  Asbestos, assessment requirement       CSO, §1735(c)
     Exposure to     See ASBESTOS, per CSO  
  Barricades           CSO, §1736(f)
  Bracing, Wall Stability         CSO, §1735(m)
  Building Demolition Requirements       CSO, §1735
  Chutes for waste disposal       CSO, §1736,(i)
    Enclosed, when Loading Trucks     CSO, §1736,(b)
      Design       CSO, §1736,(c)
    Guard Railing of Chute Openings     CSO, §1736(d)
  Cranes used in         GISO, §4941
  Debris, disposal of         CSO, §1736
  Demolishing Buildings            CSO, §1735
  Demolition Sequence         CSO, §1735(f)
  Displaced materials removal from building     CSO, §1735(e)
    As work Progresses       CSO, §1736(g)  
  Disposal of Waste Material            CSO, §1736 
    Barricading, When dropping debris without chute      CSO, §1736(f)
    Removal as work proceeds          CSO, §1736(g)
    Chute bumper/Toe Board, design and construction   CSO, §1736(i)
    Chute design and use       CSO, §1736(b), (c)
      Clogged Chute Clearing     CSO, §1736(c)
    Chute openings, open spaces     CSO, §1736(d)
    Debris removal without the use of a chute   CSO, §1736(f)
    Guarding/Barricading Chute Discharge End   CSO, §1736(e)
    Guarding Chute openings, open spaces   CSO, §1736(d)
    Flammable materials, storage     CSO, §1736(h)
    Waste material removal       CSO, §1736(g)
  Dust control         CSO, §1735(t)
  Elevators for hoisting employees       CSO, §1735(r)
  Engineering survey before start of Work     CSO, §1734(b)
  Fall Protection          CSO, §1735(k) 
  Floor openings, guarding when using mechanical equipment   CSO, §1735(v) 
  Falling materials, protection from       CSO, §1735(j)
  Beams planked over         CSO, §1735(s)
  Floor Openings Guarding for Mechanical Equipment   CSO, §1735(v)
  Floor Stability         CSO, §1735(f)
  Floor structure safe for mechanical equipment     CSO, §1735(u)
  Floor Structure Safe for Mechanical Equipment     CSO, §1735(u)
  Glazing, Glass Wall Openings       CSO, §1735(l)
  Hazardous, Flammable, Explosive Materials     CSO, §1735(b)
    Disposal of         CSO, §1736(h)
  Inspections            
    Before Start of Work       CSO, §1734(b) 
    Continuing during Demolition     CSO, §1735(d)(4)
  Ladder requirement         CSO, §1735(p)(2)
  Walkways or ladders shall be provided     CSO, §1735(p)(3)
  Lighting requirement         CSO, §1735(q)
  Permit Requirement       See Cal/OSHA, 341(d)(3)  
  Piping Dismantling, Pressure Relieving before     GISO, §3329(d)
  Planking, Floor Substitute       CSO, §1735(o)
  Safety Nets or Planking Required       CSO, §1735(s)
  Salvage of materials, prohibition       CSO, §1735(w)  
  Stability of Structure         CSO, §1735(d)
  Stairways to be clear for use       CSO, §1735(p)
  Steel Construction         CSO, §1735(n)
  Supervision Requirement for Demolition     CSO, §1734(a)  
  Survey of Structure / Building       CSO, §1734(b)
  Utility companies notification       CSO, §1735(a)
  Walking across Joists, Beams, Girders Prohibited     CSO, §1735(i)
  Walkways           CSO, §1735(h)
  Walkways or ladders shall be provided     CSO, §1735(p)(3)
  Wall Stability         CSO, §1735(m)
  Waste disposal         CSO, §1736
    Barricading, When dropping debris without chute      CSO, §1736(f)
    Removal as work proceeds          CSO, §1736(g)
    Chute bumper/Toe Board, design and construction   CSO, §1736(i)
    Chute design and use       CSO, §1736(b), (c)
      Clogged Chute Clearing     CSO, §1736(c)
    Chute openings, open spaces     CSO, §1736(d)
    Debris removal without the use of a chute   CSO, §1736(f)
    Guarding/Barricading Chute Discharge End   CSO, §1736(e)
    Guarding Chute openings, open spaces   CSO, §1736(d)
    Flammable materials, storage     CSO, §1736(h)
    Waste material removal       CSO, §1736(g)
DEPRESSIONS, Dangerous, in Roadway, Walkways, Storage Areas   GISO, §3273(b)
DERRICK or CRANE SUSPENDED PERSONNEL PLATFORM / MANBASKET GISO, §5004
  Anti Two-Block Device         GISO, §5004(e)(3)
  Application           GISO, §5004(a)
  Design Criteria         GISO, §5004(f)
  Exception to Prohibited Use       GISO, §5004(a)
  Free Fall Prohibition         GISO, §5004(e)
  Instrument & Component Requirements     GISO, §5004(e)
  Loading Requirements         GISO, §5004(h)
  Operating Criteria         GISO, §5004(d)
  Pre-Lift Meeting         GISO, §5004(m)
  Rigging of           GISO, §5004(i)
  Scope of §5004         GISO, §5004(a)
  Specifications         GISO, §5004(g)
  Traveling of Hoist or Crane       GISO, §5004(l)
  Trial Lift, Inspection & Proof Testing       GISO, §5004(j)
  Work Practices         GISO, §5004(k)
DERRICKS IN CONSTRUCTION (CSO)       CSO, Article 15
    Application & Scope       CSO, §1610.1
    Definitions         CSO, §1610.3
    General Requirements        
      Design Standards     CSO, §1610.2
      Design, Construction & Testing   CSO, §1610.4
      Equipment Modifications     CSO, §1610.6
      Equipment/ Rated 2,000 Pounds or Less.  CSO, §1610.8
      Equipment/ Rated Over 3 Tons    CSO, §1610.9
      Fall Protection     CSO, §1610.7
      Ground Conditions     CSO, §1610.5
      Scope       CSO, §1610.1
  Assembly & Disassembly of Cranes/ Derricks      
    Disassembling of Booms & Jibs, Additional Requirements  CSO, §1611.3
    Employer Procedures - General Requirements   CSO, §1611.4
    General Requirements       CSO, §1611.2
    Manufacturer or Employer Procedures     CSO, §1611.1
    Power Line Safety (Up to 350 kV)     CSO, §1611.5
  Barge Mounted Cranes/Derricks       CSO, §1619.3
  Construction, Design & Testing       CSO, §1610.4
    Equipment Modifications       CSO, §1610.6
  Crane Operations          
    Authority to Stop/Halt Operation     CSO, §1616.2
    Free Fall and Controlled Load Lowering   CSO, §1616.5
    Hoisting Personnel       CSO, §1616.6
    Multiple-Crane/Derrick Lifts     CSO, §1616.7
    Operation of Cranes/Derricks     CSO, §1616.1
    Overhead Loads       CSO, §1616.4
    Work Area Control       CSO, §1616.3
  Design Standards         CSO, §1610.2
    Design, Construction & Testing     CSO, §1610.4
    Equipment Modifications       CSO, §1610.6
  Derricks           CSO, §1619.2
  Equipment Modifications       CSO, §1610.6
  Equipment/ Rated 2,000 Pounds or Less.      CSO, §1610.8
  Equipment/ Rated Over 3 Tons        CSO, §1610.9
  Fall Protection         CSO, §1610.7
  Floating Cranes/Derricks         CSO, §1619.3
  General Requirements         CSO, §1610
  General Requirements          
    Design Standards       CSO, §1610.2
    Design, Construction & Testing     CSO, §1610.4
    Equipment Modifications       CSO, §1610.6
    Equipment/ Rated 2,000 Pounds or Less.    CSO, §1610.8
    Equipment/ Rated Over 3 Tons      CSO, §1610.9
    Fall Protection       CSO, §1610.7
    Ground Conditions       CSO, §1610.5
    Scope         CSO, §1610.1
    Supplemental Requirements      
      Barge Mounted Cranes/Derricks   CSO, §1619.3
      Derricks       CSO, §1619.2
      Floating Cranes/Derricks     CSO, §1619.3
      Overhead & Gantry Cranes   CSO, §1619.4
      Pile Drivers (Dedicated)     CSO, §1619.5
      Tower Cranes     CSO, §1619.1
  Ground Conditions         CSO, §1610.5
  Inspection of          
    Annual/Comprehensive       CSO, §1613.6
    Equipment Not in Regular Use     CSO, §1613.8
    General Inspections       CSO, §1613.9
    Modified Equipment       CSO, §1613.1
    Periodic         CSO, §1613.5
    Post Assembly       CSO, §1613.3
    Repaired/Adjusted Equipment     CSO, §1613.2
    Severe Service/ Damage or Excessive Wear   CSO, §1613.7
    Shift, After Each       CSO, §1613.4
    Wire Rope         CSO, §1613.10
  Operation Requirements          
    Authority to Stop/Halt Operation     CSO, §1616.2
    Free Fall and Controlled Load Lowering   CSO, §1616.5
    Hoisting Personnel       CSO, §1616.6
    Multiple-Crane/Derrick Lifts     CSO, §1616.7
    Operation of Cranes/Derricks     CSO, §1616.1
    Overhead Loads       CSO, §1616.4
    Work Area Control       CSO, §1616.3
  Overhead & Gantry Cranes       CSO, §1619.4
  Pile Drivers (Dedicated)         CSO, §1619.5
  Power Line Safety          
    Assembly & Disassembly near Power Lines Up to 350 kV CSO, §1611.5
    Equipment Operations near Power Lines Up to 350 kV CSO, §1612.1
    Equipment Operations near Power Lines Over350 kV CSO, §1612.2
    Equipment Operations near Power Lines closer than Table A Zone CSO, §1612.3
    Equipment Travel under or Near Power Lines (No Load) CSO, §1612.4
  Qualification & Training          
    Operator Qualification and Certification   CSO, §1618.1
    Maintenance and Repair Employees Qualification   CSO, §1618.3
    Signal Person Qualification     CSO, §1618.2
    Training         CSO, §1618.4
  Riding on loads prohibited        CSO, §1718
  Safety Devises         CSO, §1615
    Operational Aids       CSO, §1615.2
    Safety Devises       CSO, §1615.1
  Signals           CSO, §1617
    General Requirements       CSO, §1617.1
    Radio, Telephone or Other Electronic Transmission of Signals CSO, §1617.2
    Voice Signals - Additional Requirements   CSO, §1617.3
  Supplemental Requirements        
    Barge Mounted Cranes/Derricks     CSO, §1619.3
    Derricks         CSO, §1619.2
    Floating Cranes/Derricks       CSO, §1619.3
    Overhead & Gantry Cranes     CSO, §1619.4
    Pile Drivers (Dedicated)       CSO, §1619.5
    Tower Cranes       CSO, §1619.1
  Testing, Construction & Design        CSO, §1610.4
  Tower Cranes         CSO, §1619.1
  Wire Rope Selection & Installation Criteria     CSO, §1614
    Inspection of       CSO, §1613.10
DERRICKS, per ESO            
  Electrical Operations involving Derricks & Hoisting Equipment   ESO-HV, §2940.7(c)  
    Hoisting Devices       ESO-HV, §2940.7(d)
    Hoisting Cables       ESO-HV, §2940.7(e)
    Clearance to Exposed Energized Parts     ESO-HV, §2940.7(c)(2)
    Comply with GISO, Articles 91-100     ESO-HV, §2940.7(c)(1)
    Contact with Exposed Energized Parts, Precautions   ESO-HV, §2940.7(c)(3)
    Hoisting Cables        ESO-HV, §2940.7(e)
    Hoisting Devices        ESO-HV, §2940.7(d)
    Warning signs, high-voltage overhead lines   ESO-HV, §2947
DERRICKS, per GISO            
              See also CRANES & Hoisting Equipment
    Illustrations, Types of Derricks     GISO, §4885, Plate II
    General Requirements     See under CRANES  
  Access to Sheaves, Bearings and Blocks     GISO, §4963
  Accident Prevention, High Voltage Area     GISO, §5003
  Adjustments and Repair of        GISO, §5034
  Barge Mounted derricks, illustrations       GISO, §4885 Plate III
    Permanently Mounted        GISO, §4943
  Bearings, access to         GISO, §4963
  Blocks, access to         GISO, §4963
  Certification Of         GISO, Article 99
  Construction of          GISO, §4960
  Definitions           GISO, §4885
  Derrick Signals, Communication        GISO, §4964
  Examination certificate         GISO, §4885, Plate V
    Testing certificate       GISO, §5025
  Examination, Proof Load Test &       GISO, §5022
  Fire extinguisher         GISO, §4997
  Floating A-frame derricks       GISO, §4943
  Floating derricks, illustrations       GISO, §4885 Plate III
    Permanently Mounted        GISO, §4943
  Hoisting ropes         GISO, §4962
  Guying, Anchoring          GISO, §4960(a)
  Reinforcing steel, prohibitions       GISO, §4960(b)
  Hoist Holding Mechanism        GISO, §4960(c)
  Hoisting Ropes          GISO, §4962
  Illustrations of         GISO, §4885 Plate II
  Inspections           GISO, §5031
  Licensing of Certifying Agent     See Cal/OSHA, §344.60  
  Loads            
    Handling         GISO, §4999
    Overhead loads, employee safety     GISO, §5002
    Proof load testing       GISO, §5023
    Rigging by Qualified Person (Rigger)     GISO, §4999(a)
    Safe working load        
      Determination     GISO, §5026
      Increase of       GISO, §5028
      Reduction of     GISO, §5027
  Non-Permanent Operations, Rating Chart      GISO, §4961(b)
  Testing, Proof Load Test & Examination     GISO, §5022
  Maintenance, preventive       GISO, §5033
  Operating practices         GISO, §5008
  Operating Rules for Derricks       GISO, Article 98
    Driver’s Position       GISO, §4996
    Fire Extinguisher       GISO, §4997
    Fueling, Refueling       GISO, §4998
    Handling Loads       GISO, §4999
    High Voltage Lines, Accident Prevention    GISO, §5003
    Limit Switches       GISO, §5000
    Overhead Loads       GISO, §5002
    Operator Practices       GISO, §5008
    Operator Qualifications       GISO, §5006
    Rigging by Qualified Person (Rigger)     GISO, §4999(a)
    Scope of Article 98       GISO, §4990
    Signals, Signal Person       GISO, §5001
    Suspended Personnel Platforms     GISO, §5004(d)
    Travel of Derricks       GISO, §4991
    Ridding Load Prohibited       GISO, §4995
  Operator Qualifications         GISO, §5006
    Trainees, for       GISO, §5006(b)
  Overhead high-voltage lines, Accident Prevention     GISO, §5003
  Petroleum Drilling Operations, Use of Derricks   See DERRICKS, Oil & Gas Drilling & Production per PSO-D&P
  Preventive Maintenance Program       GISO, §5033
  Rated Load Marking          GISO, §4961
  Rating Chart         GISO, §4961(a)
  Refueling engines         GISO, §4998
  Repairs and Adjustments       GISO, §5034
  Riding on loads prohibited, per CSO       CSO, §1718
  Riding on loads prohibited, per GISO       GISO, §4995
  Safe Working Load Determination       GISO, §5026
  Sheaves, access to          GISO, §4963
  Signals           GISO, §4964
    Illustrations         GISO, §5001 Plates
  Suspended Personnel Platforms       GISO, §5004
    Anti Two-Block Device       GISO, §5004(e)(3)
    Application         GISO, §5004(a)
    Design Criteria       GISO, §5004(f)
    Exception to Prohibited Use     GISO, §5004(a)
    Free Fall Prohibition       GISO, §5004(e)
    Instrument & Component Requirements   GISO, §5004(e)
    Loading Requirements       GISO, §5004(h)
    Operating Criteria       GISO, §5004(d)
    Pre-Lift Meeting       GISO, §5004(m)
    Rigging of         GISO, §5004(i)
    Scope of §5004       GISO, §5004(a)
    Specifications       GISO, §5004(g)
    Traveling of Hoist or Crane     GISO, §5004(l)
    Trial Lift, Inspection & Proof Testing     GISO, §5004(j)
    Work Practices       GISO, §5004(k)
  Testing of           GISO, §5020
    Certificate, indicating       GISO, §5025
    Derricks over 3 tons rated capacity     GISO, §5021
    Operational testing       GISO, §5020
    Proof load test       GISO, §5023
    Safe working load, determination     GISO, §5026
      Decrease of       GISO, §5027
      Increase of       GISO, §5028
  Types of derricks, illustrations       GISO, §4885 Plate II
DERRICKS, Oil & Gas Drilling & Production per PSO-D&P      
  Access to Derricks & Mast Floors       PSO-D&P, §6579
  Auxiliary Means of Escape from       PSO-D&P, §6573
  Blocks & Block Hooks, Traveling, or Similar     PSO-D&P, §6638
  Cantilever Derricks & Masts, Sheaves, Guarding of     PSO-D&P, §6636
  Catwalk at Drilling Wells        PSO-D&P, §6572
  Construction & Maintenance       PSO-D&P, §6568
  Crown Blocks         PSO-D&P, §6571
  Crown Platforms & Railings        PSO-D&P, Article 25
    Access & Lubrication        PSO-D&P, §6592(a)
      Ladder Requirements      PSO-D&P, §6592(b)
    Gin Pole Masts, Stationary or Portable    PSO-D&P, §6589
    Portable Cantilever Derricks & Masts     PSO-D&P, §6590
    Portable Jackknife Derricks & Masts     PSO-D&P, §6591
    Telescoping Derricks & Masts     PSO-D&P, §6591
  Crown Platform & Railings for Standard Type Derrick   PSO-D&P, §6562
  Derricks, Standard Type,        PSO-D&P, Article 18
    Blocks & Block Hooks, Traveling, or Similar   PSO-D&P, §6638
    Crown Platform & Railings     PSO-D&P, §6562
    Derrick installations, New & Old     PSO-D&P, §6558
      Group I, II & III Defined, By Installation Date PSO-D&P, §6558(a)
      Abbreviations, groups of derricks   PSO-D&P, §6558(b)
    Derrick Ladder Requirements     PSO-D&P, §6564
      Inside Platform Requirements    PSO-D&P, §6560
      Ladderway Openings in Platforms    PSO-D&P, §6565
    Gin Pole, Derrick       PSO-D&P, §6563
    Guying Derricks       PSO-D&P, §6566
    Ladderway Openings in Platforms      PSO-D&P, §6565
    Line Spoolers & Deadline Stabilizers     PSO-D&P, §6688
    Outside Derrick Platform Requirements   PSO-D&P, §6561
    Sheaves, Guarding of       PSO-D&P, §6636
    Tools, Equipment & Materials, Only Essential   PSO-D&P, §6603
    Wire Rope Lines       PSO-D&P, §6640
      Weight Indicators for Wire Hoisting Ropes PSO-D&P, §6690
  Equipment, Tools & Materials, Only Essential     PSO-D&P, §6603
  Erection of Derricks & Masts       PSO-D&P, Article 23
    Hydraulic Lifts for Derricks & Masts     PSO-D&P, §6583
    Portable Telescoping Derricks & Masts   PSO-D&P, §6582
    Telescoping Gin Pole Masts     PSO-D&P, §6584
  Escape, Auxiliary Means of       PSO-D&P, §6573
  Escape Lines         PSO-D&P, §6574 
  Exit from Derricks & Mast Floors       PSO-D&P, §6579
  Fall Protection Requirements       PSO-D&P, §6580
  Fingers, Finger Boards & Finger Braces     PSO-D&P, §6569
  Gin Pole Masts         PSO-D&P, §6589
    Sheaves, Guarding of       PSO-D&P, §6636
  Guying Derricks & Masts       PSO-D&P, §6586
  Illumination / Lighting         PSO-D&P, §6657
  Jackknife Derricks & Masts, Sheaves, Guarding of     PSO-D&P, §6636
  Ladders & Ladderway Openings for Derricks & Masts   PSO-D&P, Article 28
    Ladders Requirements       PSO-D&P, §6599
    Pole Steps for Gin Pole Masts     PSO-D&P, §6600
  Line Spoolers & Deadline Stabilizers       PSO-D&P, §6688
  Materials, Equipment & Tools & Only Essential     PSO-D&P, §6603
  Pipe Racking Supports for Derricks & Masts     PSO-D&P, §6596
  Pipe Storage at Drilling Wells        PSO-D&P, §6572
  Pipe & Sucker Rod Platforms for Derricks & Masts     PSO-D&P, Article 26
    Platforms & Access Requirements     PSO-D&P, §6594
    Platforms, Portable Cantilever Derricks & Masts   PSO-D&P, §6595
  Railings          See Crown Platforms & Railings  
  Rope Lines, Wire         PSO-D&P, §6640
  Safety Belts & Lanyards, Derrick / Mast Work     PSO-D&P, §6580
  Shafts & Cellars         PSO-D&P, Article 20
    Construction & Maintenance     PSO-D&P, §6576
    Entrance & Exit        PSO-D&P, §6577
  Sheaves, Guarding of         PSO-D&P, §6636
  Stabbing Boards          PSO-D&P, §6570
  Telescoping Derricks & Masts       PSO-D&P, §6591
    Sheaves, Guarding of       PSO-D&P, §6636
  Tools, Equipment & Materials, Only Essential     PSO-D&P, §6603
  Weight Indicators for Wire Rope Hoisting Lines     PSO-D&P, §6690
  Wire Rope Lines         PSO-D&P, §6640
DESIGNATED BATTERY CHARGE LOCATION       GISO, §5185
  Corrosive Liquids, Spill Remediation, Neutralizing      GISO, §5185(c)
  Electrolyte Dispensing         GISO, §5185(d)
  Electrolyte Mixing Area, Ventilated       GISO, §5185(i)
  Employee Instruction         GISO, §5185(a)
  Emergency Operations         GISO, §5185(a)
  Eye & Body Flushing & Drenching Area     GISO, §5185(l)
  Handling, Battery Lifting Devices       GISO, §5185(f)
  Ignition Sources, Prevention       GISO, §5185(h)
  Location designed for         GISO, §5185(a)
  Mobile Equipment         GISO, §5185(d)
  Physical Damage Prevention, Charging Equipment     GISO, §5185(e)
  Smoking Prohibition         GISO, §5185(g)
  Spark Proof Tools & Equipment       GISO, §5185(h)
  Spill Remediation, Neutralizing Corrosive Liquids      GISO, §5185(c)
  Storage Racks, Non-conductive       GISO, §5185(h)
  Vent Caps           GISO, §5185(k)
  Ventilation of Area         GISO, §5185(b)
DETERIORATING AGENTS / CONDITIONS, per ESO     ESO-LV, §2340.11
  Damp Locations         ESO-LV, §2340.11(a)(1)
  Gases, Fumes, liquids or Other       ESO-LV, §2340.11(a)(2)   
  Temperatures, Excessive         ESO-LV, §2340.11(a)(3)  
  Wet Locations         ESO-LV, §2340.11(a)(1)  
DEVICES, Approvals of           GISO, §3206
DIACETONE ALCOHOL, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIACETYL, Occupational Exposure to Food Flavorings Containing   GISO, §5197
  Access to Records         GISO, §5197(k)(1)
  Application & Scope         GISO, §5197(a)
  Definitions, Specific to Section 5197       GISO, §5197(b)
    Selected Terms in Subsection (b):        
      American Thoracic Society Guidelines   GISO, §5197(b)(1)
      CDPH Guidelines     GISO, §5197(b)(3)
      Diacetyl-containing     GISO, §5197(b)(7)
      Enclosed process     GISO, §5197(b)(8)
      Fixed Obstructive Lung Disease   GISO, §5197(b)(10)
      Medical guidelines     GISO, §5197(b)(16)
      OSHA Method     GISO, §5197(b)(19)
      OSHA reliable quantitation limit (OSHA RQL) GISO, §5197(b)(20)
      Other artificial butter flavoring   GISO, §5197(b)(21)
      Program reviewer     GISO, §5197(b)(24)
      Reliable quantitation limit (RQL)   GISO, §5197(b)(26)
      Spirometric Reference Values   GISO, §5197(b)(28)
  Diacetyl Control Program, Written        GISO, §5197(e)(5)
    Program Evaluation       GISO, §5197(e)(6)
  Employee Notification, of Exposure Assessment     GISO, §5197(c)(5)
  Engineering Controls & Work Practices     GISO, §5197(e)
    Written Diacetyl Control Program     GISO, §5197(e)(5)
      Program Evaluation     GISO, §5197(e)(6)
  Exposure assessment         GISO, §5197(c)
    Employee Notification, of Exposure Assessment   GISO, §5197(c)(5)
    General Requirements       GISO, §5197(c)(1)
    Initial Monitoring       GISO, §5197(c)(2)
    Periodic Monitoring       GISO, §5197(c)(3)
      Additional Monitoring     GISO, §5197(c)(4)
  Information &Training         GISO, §5197(j)(1)
    Awareness Training       GISO, §5197(j)(1)(A)
    Additional Training       GISO, §5197(j)(1)(B)
      Frequency of      GISO, §5197(j)(1)(B)1.
      Content       GISO, §5197(j)(1)(B)2.
  Labeling Containers in the Workplace       GISO, §5197(j)(2)
    In Lieu if Labeling       GISO, §5197(j)(2)(C)
  Laboratory Analysis, Protocol       GISO, §5197, Appx A
  Medical Removal of Employees       GISO, §5197(i)
    Workers' Compensation Claims     GISO, §5197(i)(2) 
  Medical Surveillance         GISO, §5197(g)
    PLHCP Written Opinion       GISO, §5197(h)
    Questionnaires, Respiratory Health     GISO, §5197, Appx B
  Monitoring, Exposure Assessment       GISO, §5197(c)
    Employee Notification, of Exposure Assessment   GISO, §5197(c)(5)
    General Requirements       GISO, §5197(c)(1)
    Initial Monitoring       GISO, §5197(c)(2)
    Periodic Monitoring       GISO, §5197(c)(3)
      Additional Monitoring     GISO, §5197(c)(4)
  Posting, Report of Use Notification       GISO, §5197(k)(3)(C)
  Questionnaires, Respiratory Health       GISO, §5197, Appx B
  Record keeping         GISO, §5197(k)(1)
  Regulated Areas         GISO, §5197(d)
  Report of Employee Diagnosis to Cal/OSHA     GISO, §5197(k)(2)
  Report of Use         GISO, §5197(k)(3)
    Cal/OSHA Notification of       GISO, §5197(k)(3)(A)
    Included in Report       GISO, §5197(k)(3)(B)
    Posting of Report       GISO, §5197(k)(3)(C)
  Respirator Protection         GISO, §5197(f)
    Selection Table       GISO, §5197(f)(3)
  Sampling Protocol         GISO, §5197, Appx A
  Training           GISO, §5197(j)(1)
    Awareness Training       GISO, §5197(j)(1)(A)
    Additional Training       GISO, §5197(j)(1)(B)
      Frequency of      GISO, §5197(j)(1)(B)1.
      Content       GISO, §5197(j)(1)(B)2.
  Workers' Compensation         GISO, §5197(a) Note 2, & (i)(2) 
  Work Practices & Engineering Controls     GISO, §5197(e)
    Written Diacetyl Control Program     GISO, §5197(e)(5)
      Program Evaluation     GISO, §5197(e)(6)
DIACETYL PEROXIDE            
  Process Safety Management       GISO, §5189, Appx A
DIAZINON, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIAZOMETHANE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
  Process Safety Management       GISO, §5189, Appx A
DIBENZOYL PEROXIDE          
  Process Safety Management       GISO, §5189, Appx A
DIBORANE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
  Process Safety Management       GISO, §5189, Appx A
DIBROM, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
1, 2 DIBROMO-3-CHLOROPROPANE (DPCP) (Nemagon)     GISO, §5212
  "             "              "               "              "                "      See Also CARCINOGENS, Regulated
    Application & Scope       GISO, §5212(a)
    Definitions          GISO, §5212(b)
  Appendices, Application of       GISO, §5212(r)
  Change Room         GISO, §5212(j)(1)
  Emergencies, Notification per §5203        GISO, §5212(d)
  Emergency Plan         GISO, §5212(i)
  Exposure Monitoring          GISO, §5212(f)
    General          GISO, §5212(f)(1) 
    Initial          GISO, §5212(f)(2) 
    Frequency          GISO, §5212(f)(3) 
    Additional Monitoring        GISO, §5212(f)(4) 
    Employee Notification of        GISO, §5212(f)(5) 
    Accuracy of Measurement      GISO, §5212(f)(6)
  Exposure to, as Airborne Contaminant       GISO, §5155, & Appx A
  Housekeeping / Cleaning        GISO, §5212(k)
  Hygiene Facilities & Practices        GISO, §5212(l) 
    Change Rooms        GISO, §5212(l)(1)
    Showers          GISO, §5212(l)(2)
    Lunchrooms        GISO, §5212(l)(3)
    Sanitation          GISO, §5212(l)(4)
    Prohibition of Activities       GISO, §5212(l)(5)
  Medical Surveillance          GISO, §5212(m)
  Methods of Compliance          GISO, §5212(g)
    Priority of Compliance Methods      GISO, §5212(g)(1)
    Compliance Program        GISO, §5212(g)(2)
  Notification of Use per §5203        GISO, §5212(d)
  Permissible Exposure Limit        GISO, §5212(c)
    Inhalation of airborne DBCP     GISO, §5212(c)(1)
    Dermal & Eye Exposure        GISO, §5212(c)(2)
  Respirators          GISO, §5212(h)
    General          GISO, §5212(h)(1)
    Respirator program        GISO, §5212(h)(2) 
    Respirator Selection        GISO, §5212(h)(3)
  Protective Clothing & Equipment        GISO, §5212(j)
  Training & Employee Information        GISO, §5212(n) 
    Training Program        GISO, §5212(n)(1)
    Access to Training Materials      GISO, §5212(n)(2)
  Signs & Labels          GISO, §5212(o)
  Record keeping           GISO, §5212(p)
    Exposure Monitoring        GISO, §5212(p)(1)
    Medical Surveillance        GISO, §5212(p)(2)
    Availability of        GISO, §5212(p)(3)
    Transfer of Records        GISO, §5212(p)(4)
  Regulated Areas          GISO, §5212(e)
    Establishment of        GISO, §5212(e)(1)
    Demarcation & Segregation      GISO, §5212(e)(2)
    Signs, Posting of        GISO, §5212(e)(2)
    Access to         GISO, §5212(e)(3)
  Observation of Monitoring        GISO, §5212(q)
DIBUTYLAMINOETHANOL, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIBUTYL PEROXIDE            
  Process Safety Management       GISO, §5189, Appx A
DIBUTYL PHENYL PHOSPHATE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIBUTYL PHOSPHATE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIBUTYL PHTHALATE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROACETYLENE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
  Process Safety Management       GISO, §5189, Appx A
DICHLOROBENZENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
3,3'-DICHLOROBENZIDINE(& its Salts)      See CARCINOGENS, Specified  
DICHLOROBUTENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLORODIFLUOROMETHANE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLORODIMETHYL HYDANTOIN, Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROETHANE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROETHYLENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROETHYL ETHER, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROFLUOROMETHANE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROMETHANE, METHYLENE CHLORIDE (MC)     GISO, §5202
    Application & Scope       GISO, §5202(a)
    Definitions          GISO, §5202(b)
  Appendices         GISO, §5202(p)
  Communication of hazards, Employer Duty      GISO, §5202(k)
  Data sheet, Health Hazard       GISO, §5202, Appx A
  Effective Dates         GISO, §5202(n)
  Emergencies, Respirator Protection       GISO, §5202(g)(1)
  Employee Information & Training       GISO, §5202(l)
  Exposure monitoring          GISO, §5202(d)
  Exposure limits           
    Eight-hour time-weighted average (TWA) PEL   GISO, §5202(c)(1)
    Short-term exposure limit (STEL)      GISO, §5202(c)(2)
  First Aid  Procedure         GISO, §5202, Appx A
  Handling, Use, & Storage        GISO, §5202, Appx A
  Hazard Communication, Employer Duty     GISO, §5202(k)
  Hygiene Facilities         GISO, §5202(i)
  Identification of         GISO, §5202, Appx A
  Medical Surveillance         GISO, §5202(j)
  Methods of compliance         GISO, §5202(f)
  Monitoring, Exposure          GISO, §5202(d)
    Monitoring Methods       GISO, §5202, Appx A
  Permissible exposure limits (PELs)        GISO, §5202(c)
    Eight-hour time-weighted average (TWA) PEL   GISO, §5202(c)(1)
    Short-term exposure limit (STEL)      GISO, §5202(c)(2)
  Protective Work Clothing & Equipment     GISO, §5202(h)
  Record keeping          GISO, §5202(m)
  Regulated areas         GISO, §5202(e)
  Reporting requirements Pursuant to §5203     GISO, §5202(o)
  Respiratory protection         GISO, §5202(g)
  Storage            GISO, §5202, Appx A
  Technical Data & Guidelines        GISO, §5202, Appx A
  Training           GISO, §5202(l)
  Use, Handling & Storage        GISO, §5202, Appx A
DICHLORONITROETHANE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
2,4-DICHLOROPHENOXY ETHYL SODIUM SULFATE( Sesone)    
  Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROPROPENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROPROPIONIC ACID, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROSILANE             
  Process Safety Management       GISO, §5189, Appx A
DICHLOROTETRAFLUOROETHANE, Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICHLOROVOS, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICROTOPHOS, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICYCLOPENTADIENE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DICYCLOPENTADIENYL IRON, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIE CASTING MACHINES         GISO, Article 57
  Cold chamber machines          
    Controls         GISO, §4261
    Helper’s protection       GISO, §4263
  Controls           GISO, §4261
    Activating plunger in shot sleeve     GISO, §4262
    Two-Hand Controls, Hot & Cold Chamber Die Casting Machines GISO, §4261(a)
    Two-Hand Controls, Cold Chamber Machines   GISO, §4261(e)
    One-Hand Controls       GISO, §4261(b)
    Sliding Gate Guard interlock     GISO, §4261(c)
    Equivalent Controls       GISO, §4261(d)
  Helper’s protection         GISO, §4263
  Holding furnaces         GISO, §4266
  Hot chamber machines          
    Controls         GISO, §4261
    Helper’s protection       GISO, §4263
  Ladling Operations         GISO, §4262
  Plungers controls         GISO, §4264
  Shields           GISO, §4265
DIE, Press Brake Die, Definition         GISO, §4188(a)
DIELECTRIC & INDUCTION HEATING EQUIPMENT     ESO-LV, Article 77.2
  Application / Scope         ESO-LV, §2567.1
  Guarding & Grounding         ESO-LV, §2567.2
  Remote Controls         ESO-LV, §2567.3
DIELDRIN, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIES, Design, Construction, Setting & Feeding of       GISO, §4197
DIESEL ENGINES, per CSO          
  Exhaust Retrofit, Definition       CSO, §1504(a)
    Access of Vehicle not Obstructed     CSO, §1591(m)(2)
    Engine Performance       CSO, §1591(m)(1)
    Installation of Exhaust Retrofit     CSO, §1591(m)
    Fire Hazard, Effectively Shielded      CSO, §1591(m)(3)
    Hot Surfaces of Exhaust System, Operator Shielding from CSO, §1591(m)(4)
    Obstruction of Operator's View     CSO, §1591(m)(5)
    Exhaust Stack Requirements     CSO, §1591(m)(6)
    Maintenance of Exhaust Retrofit     CSO, §1591(m)
    Visibility Testing Applied to Exhaust Retrofit   CSO, §1591, Appx A
  Operated Inside Structures, Shafts, Culverts and Others   CSO, §1533
    Confined Space Requirements     CSO, §1533(c)
    Control of Exhaust Fumes     CSO, §1533(a)
    Ventilation Requirements       CSO, §1533(b)
      Ventilation Systems, General Requirements CSO, §1530
DIESEL ENGINES, per MSO          
  Fueling of Diesel Engines, Underground     MSO, §7071
  Permitted Use of Diesel Engines, Underground     MSO, §7070
  Prohibition of Engine Near Mine Opening      MSO, §7068
  Prohibition of Engines Underground       MSO, §7069
  Use in Underground Mining permitted       MSO, §7070
DIESEL ENGINES, per PSO          
  Stationary Engines per PSO-R,T&H       PSO-R,T&H, §6874
  Worksites Subject to PSO-D&P        PSO-D&P, §6684
    Application / Scope of §6684      PSO-D&P, §6684(a)
    Battery Covers, to Prevent Inadvertent Contact   PSO-D&P, §6684(h)
    Combustible material, prohibitions     PSO-D&P, §6684(d) 
    Cylinder Cocks       PSO-D&P, §6684(e)
    Electrical Accessories for ICE     PSO-D&P, §6684(f)
    Electrical Storage Batteries     PSO-D&P, §6684(h)
    Emergency Stop Device, Air and Gas Compressors   PSO-D&P, §6554(h)
    Emergency Stop Device, Drilling Equipment   PSO-D&P, §6625 
    Exhaust System Maintenance      PSO-D&P, §6684(c)
    Flywheels         PSO-D&P, §6682
    Ignition Systems, prohibitions     PSO-D&P, §6684(g) 
    Overspeed (Runaway) Protection, Air and Gas Compressors PSO-D&P, §6554(h)
    Overspeed (Runaway) Protection, Diesel Engines   PSO-D&P, §6625.1
    Overspeed (Runaway) Protection, Oil & Gas Drilling & Servicing Machinery PSO-D&P, §6625 
    Power Controls        PSO-D&P, §6681
    Precautions        PSO-D&P, §6554
    Safety Precautions       PSO-D&P, §6684(b) 
    Starters for Internal Combustion Engines   PSO-D&P, §6685
DIESEL ENGINES, per TSO          
  Application for Diesel Engine Permit        TSO, §8470(b)
    Processing Time       TSO, §8470(l)
  Carbon Dioxide, Testing         TSO, §8470(d)
  Carbon Monoxide, Testing        TSO, §8470(d)
  Diesel Engine Permitted in Writing        TSO, §8470(a)
  Diesel Fuel, Sulphur (Sulfur) Content       TSO, §8470(i)
  Fresh Air Flow Where Diesel Engine is Operating      TSO, §8470(c)
  Monitoring exhaust         TSO, §8470
  Prohibition, Except Diesel       TSO, §8470
  Locomotives, Haulage         TSO, §8471 
  Nitrogen Dioxide, Testing       TSO, §8470(d), & Note
  Nitrogen Dioxide, Exposure       TSO, §8470(e)
  Testing, Air Contaminants       TSO, §8470(d)
  Application for Diesel Engine Permit        TSO, §8470(b)
  Carbon Dioxide, Testing         TSO, §8470(d)
  Carbon Monoxide, Testing        TSO, §8470(d)
  Diesel Engine Permitted in Writing        TSO, §8470(a)
  Fresh Air Flow Where Diesel Engine is Operating      TSO, §8470(c)
  Prohibition of Internal Combustion Engine, Except Diesel   TSO, §8470
  Locomotives, Haulage         TSO, §8471 
  Nitrogen Dioxide, Testing       TSO, §8470(d)
  Testing, Air Contaminants       TSO, §8470(d)
DIESEL ENGINE OVERSPEED (RUNAWAY) PROTECTION      
  Overspeed (Runaway) Protection, Diesel Engines     PSO-D&P, §6625.1
    Air Monitoring for LEL       PSO-D&P, §6625.1(c)
    Emergency Shut Off Device (Air Intake Shut Off Valve) PSO-D&P, §6625.1(e)
    Prohibition for Restarting       PSO-D&P, §6625.1(f)
    Prohibition from Operating above 10% LEL   PSO-D&P, §6625.1(b)
    Requirements when not Air Monitoring   PSO-D&P, §6625.1(d)
    Safety Zone, 50 Feet from Well Bore     PSO-D&P, §6625.1(a)
  Overspeed (Runaway) Protection, General Industry     GISO, §3511
  Overspeed (Runaway) Protection, Oil & Gas Drilling & Servicing Machinery PSO-D&P, §6625
DIESETTING           GISO, §4199
DIETHANOLAMINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLALUMINUM CHLORIDE          
  Process Safety Management       GISO, §5189, Appx A 
DIETHYLAMINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLAMINO ETHANOL, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLENE GLYCOL DIETHYL ETHER, Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLENE GLYCOL DIMETHYL ETHER, Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLENE TRIAMINE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYL KETONE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYL PHTHALATE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIETHYLZINC            
  Process Safety Management       GISO, §5189, Appx A 
DIFLUORODIBROMOMETHANE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIGLYCIDYL ETHER, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIISOBUTYL KETONE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIISOPROPYLAMINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIISOPROPYL PEROXYDICARBONATE        
  Process Safety Management       GISO, §5189, Appx A
DIKES, Precautions, Open Surface Tanks         GISO, §5169
DIKES & DRAINAGE             
  Aboveground Tanks, per GISO       GISO, §5595(a) 
  Aboveground Tanks, per PSO-D&P        PSO-D&P §6548 
  Aboveground Tanks, per PSO-R,T&H       PSO-R,T&H, §6805(a)
DILALUROYL PEROXIDE          
  Process Safety Management       GISO, §5189, Appx A
DIMETHYLACETAMIDE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIMETHYLAMINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
4-DIMETHYLAMINOAZOBENZENE      See CARCINOGENS, Specified   
DIMETHYLANILINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIMETHYLDICHLOROSILANE          
  Process Safety Management       GISO, §5189, Appx A
DIMETHYLETHOXYSILANE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIMETHYLFORMAMIDE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
1, 1-DIMETHYLHYDRAZINE (UDMH), Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
  Process Safety Management       GISO, §5189, Appx A
DIMETHYLMERCURY           GISO, §5191, Appx A
DIMETHYL PHTHALATE, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIMETHYL SULFATE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DINITOLMIDE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DINITROANILINE            
  Process Safety Management       GISO, §5189, Appx A 
DINITROBENZENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DINITROCHLOROBENZENE          
  Process Safety Management       GISO, §5189, Appx A
DINITRO-O-CRESOL, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DINITROTOLUENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DINKING MACHINE, Leather & Composition Goods     GISO, §4510
DIOXANE, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIOXATHION, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIPHENYLAMINE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIPROPYLENE GLYCOL METHYL ETHER, Airborne Cont, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIPROPYL KETONE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIP TANKS            GISO, Article 136
                     See also FLAMMABLE LIQUIDS, GASES & VAPORS
                     See also DIPPING / IMMERSION TANKS, Open-Surface 
  Construction of          GISO, §5426
  Conveyor System          GISO, §5429
  Dip Tank Covers          GISO, §5435
  Dip Tank Liquids          
    Handling of         GISO, §5431(b)
    Heating of           GISO, §5430
    Salvage of         GISO, §5428
    Storage         GISO, §5431(a)
  Electrical & Other Sources of Ignition       GISO, §5432
  Electrostatic Apparatus         GISO, §5438
  Fire Protection          GISO, §5434
  Flow Coat           GISO, §5437
  Hardening & Tempering Tanks       GISO, §5436
  Heating Dip Tank Liquids       GISO, §5430
  Liquids Used, Storage & Handling       GISO, §5431
  Maintenance of         GISO, §5433
  Operations & Maintenance       GISO, §5433
  Roll Coating         GISO, §5439
  Salvage Tanks, Use of         GISO, §5428
  Sources of Ignition         GISO, §5432
  Static Electricity, Precautions       GISO, §5431(b)
  Ventilation           GISO, §5427
DIPPING / IMMERSION TANKS, Open-Surface         
  Ventilation & Personal Protective Equipment     GISO, §5154
    Application         GISO, §5154(a)
    Classification of Tanks       GISO, §5154(b)
      Cleaning Equipment, Spray   GISO, §5154(i)
      Hazard Determination     GISO, §5154, Table V-7
      Vapor & Gas Evolution Rate    GISO, §5154, Table V-8
    Control Methods, Other       GISO, §5154(g)
    Control Requirements       GISO, §5154(c)
      Velocity, Control     GISO, §5154, Table V-9
    Degreasing Equipment, Spray     GISO, §5154(i)
    Degreasing Equipment, Vapor     GISO, §5154(h)
    Hood Classification       GISO, §5154(d)
    Personal Protective Equipment      GISO, §5154(j)
    Push-Pull System Requirements     GISO, §5154(f)
    Ventilation Rate       GISO, §5154(e)
DIQUAT, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DISASTERS         See EMERGENCIES  
DISC SANDERS, Woodworking          GISO, §4313
DISCHARGE LOCATIONS, Drain, Trap, & Blowout     GISO, §3310
DISCLOSURE OF INFORMATION        See ACCESS, To Information to Information
DISCONNECTING MEANS, Electrical        
  Accessible Switches         GISO, §4001
  Appliances, General         ESO-LV, §2522.20
    Fixed Appliances        ESO-LV, §2522.21
    High Voltage        ESO-HV, §2718.1
    Motor-Driven Appliances     ESO-LV, §2522.26
    Portable Appliances        ESO-LV, §2522.22
    Stationary Appliances       ESO-LV, §2522.23
  De-icing and snow melting equipment, Outside     ESO-LV, §2526.50
  Disconnecting Means          ESO-HV, §2718.1
    Marking of         ESO-HV, §2718.1(a)
    Fuses, Supply Side of       ESO-LV, §2390.20
    Service Entrance       ESO-LV, §2380.1
  In-sight of Motor location       ESO-LV, §2530.86
  Marked, Labeled         ESO-LV, §2340.22
  Operable           GISO, §4001
  Plug of Cord-Connected Equipment       ESO-LV, §2527.55
DISCONTINUED CIRCUITS         ESO-LV, §2340.24
DISEASES, AEROSOL TRANSMISSIBLE       GISO, §5199
  Application & Scope         GISO, §5199(a)
  ATP (Aerosol transmissible pathogen)     GISO, §5199(b)
  Definitions           GISO, §5199(b)
  Exposure Control Plan         GISO, §5199(d)
  Engineering Controls          GISO, §5199(e)
  Laboratories         GISO, §5199(f)
  Medical Services         GISO, §5199(h)
  Personal Protective Equipment       GISO, §5199(e)
  Record keeping         GISO, §5199(j)
  Work Practice Controls          GISO, §5199(e)
  Referring Employers         GISO, §5199(c)
  Respiratory Protection         GISO, §5199(g)
  Training           GISO, §5199(i)
DISEASES, AEROSOL TRANSMISSIBLE– ZOONOTIC     GISO, §5199.1
  Application, Scope & Definitions        GISO, §5199.1(a)
  ATP (Aerosol transmissible pathogen)     GISO, §5199.1(a)(4)
  Disease control procedures         
    Work Operations involving ATP infected Animal   GISO, §5199.1(d)
    Wildlife, Exposure to potentially infectious wildlife   GISO, §5199.1(b)
    Quarantine order, Operations, due to an ATP infection GISO, §5199.1(c)
  Employee Safeguards, at no cost to employee     GISO, §5199.1(a)(3)
  Medical Services         GISO, §5199.1(d)(8)
    Exams, Evaluations       GISO, §5199.1(d)(8)(A), (B), (C), (E)
    Vaccinations       GISO, §5199.1(d)(8)(D)
  Record keeping          GISO, §5199.1(e)
  Respiratory Protection           GISO, §5199.1(d)(4)
    Quarantine order, due to an ATP infection, during Operations Involving GISO, §5199.1(c)(2)(C)
    Toxic or Asphyxiant Gases, protection  per  GISO,  §5144(g) GISO, §5199.1(c)(2)(C)
    Wildlife, Exposures, Use of N95 Respirator or Better GISO, §5199.1(b)(3)
    Work Operations involving ATP infected Animal   GISO, §5199.1(d)(4)
      Written Procedure      GISO, §5199.1(d)(1)(C)(4)
  Training           GISO, §5199.1(d)(9)
  Quarantine order, due to an ATP infection, Disease control procedures  GISO, §5199.1(c)
  Vaccinations, Medical Services       GISO, §5199.1(d)(8)
  Wildlife, Exposure to potentially infectious wildlife     GISO, §5199.1(b)
DISEASES, Cancer          See CARCINOGENS  
DISEASES, Tuberculosis, M, Respiratory Protection from     GISO, §5147
  TB Test           GISO, §5199(h)(3)
DI-SEC-OCTYL PHTHALATE, Airborne Contaminant       
  Exposure limit          GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DISHWASHING MACHINES       See Also APPLIANCES, per ESO
  Grounding, Electrical, Cord- & Plug-connected      ESO-LV, §2395.45(a)
DISMANTLING PIPING, Pressure Relieving before     GISO, §3329(d)
DISTILLERIES, Flammable & Combustible Liquids       GISO, §5629
  Fire Control, Access to Process Units        GISO, §5629(d)
  Fire Fighting Equipment          
    Portable fire extinguishment and control equipment    GISO, §5629(e) 
    Water, Availability         GISO, §5629(f) 
    Special Extinguishing Equipment       GISO, §5629(g)  
  Fired pressure vessels         GISO, §5629(b)  
  Flammable and combustible liquids, Storage      GISO, §5629(a)
  Piping systems          GISO, §5629(b) 
  Pressure Vessels         GISO, §5629(b)
  Process units, Accessible         GISO, §5629(d)
  Smoking Restrictions            GISO, §5629(h) 
  Storage, Flammable and combustible liquids     GISO, §5629(a)
  Tanks, Installation of          GISO, §5629(a)
  Unfired pressure vessels         GISO, §5629(b)
  Wharves           GISO, §5629(c) 
DISULFIRAM, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DISULFOTON, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DISYSTON, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DITCHES, Guarding of           GISO, §3273(l)
DI-TERT-BUTYL-P-CRESOL, Airborne Contaminant, Exposure limit    GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIURON, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIVERSION DAMS, DIKES, Protection against Water     MSO, §7175
DIVERSION, Drainage, for Aboveground Storage Tanks     PSO-D&P, §6548
DIVIDERS, Dough, Food Service Machinery        
  Guarding & Interlocking of        GISO, §4545
DIVING OPERATIONS, General         GISO, Article 152
    Application / Scope       GISO, §6050
    Definitions         GISO, §6051
  Basic operation procedures       GISO, §6056
  Commercial diving operations     See DIVING OPERATIONS, Commercial
  Decompression chambers       GISO, §6063
  Deviations From Requirements       GISO, §6050(a)(2)
  Dive, Basic Operation Procedures       GISO, §6056
  Dive Planning         GISO, §6055
  Dive Procedures         GISO, §6060 
  Equipment procedures and requirements     GISO, §6063
  Operation procedures         GISO, §6061
    Post-dive Procedures       GISO, §6062
  Decompression, Underwater Stage       GISO, §6061(f)(2)
  Decompression Chambers       GISO, §6063 
  Decompression Tables         GISO, §6085(a)
  Diving Operations, General Requirements     GISO, §6050
    Notice to Division       GISO, §6050(a)(2)
  Employer’s duties         GISO, §6052
  Equipment procedures and requirements     GISO, §6057 
  First-aid supplies         GISO, §6052(f)   
  General Requirements         GISO, §6052   
    Dive Team         GISO, §6052(c)  
      Medical Requirements of     GISO, §6053
      Training / Experience of     GISO, §6052(d)   
    Employer Obligation       GISO, §6052(a)
    First Aid Supplies       GISO, §6052(f)   
    Manual of Diving Safety       GISO, §6052(b)  
      Required Elements of      GISO, §6054
    Pressure Related Injury Documentation   GISO, §6052(g)(2)  
    Record of Dive       GISO, §6052(g)   
    Training, Diver Team       GISO, §6052(d)   
    Warning Flag       GISO, §6052(e)   
  HOOKAH diving, Procedure       GISO, §6056(a)(5)
  Injury, Record keeping requirements       GISO, §6058
  Inspection, Pre-Dive         GISO, §6052(c)(3)
  Liveboating, Procedure         GISO, §6056(c)
  Manual of Diving Safety         GISO, §6052(b)  
    Required Elements of        GISO, §6054
  Medical Requirements of Dive Team       GISO, §6053
    Exposure to hyperbaric conditions Limits   GISO, §6063, Appx A
  Mixed Gas Diving         GISO, §6061(a)
  Planning, Dive         GISO, §6055
  Procedures, General         GISO, §6056
    Commercial diving operations     GISO, §6061
  Post dive procedures         GISO, §6062
  Qualifications, Diver         GISO, §6052(c)(2)
    Diver-in-Training       GISO, §6052(c)(3)
    Dive Team         GISO, §6052(c)
  Record keeping  of Dive         GISO, §6052(g)
  Record keeping  of Injuries / Illnesses       GISO, §6058
  Scientific Diving Guidelines       GISO, §6063, Appx B
  SCUBA Diving, Procedure       GISO, §6056(a)(2)
    Equipment procedures and requirements   GISO, §6057
  Surface-supplied-air Diving Procedure       GISO, §6056(b)
  The Dive Team         GISO, §6052(c)
  Training and Experience         GISO, §6052(d)
  Warning flags         GISO, §6052(e)   
DIVING OPERATIONS, Commercial         GISO, Article 153
    Application / Scope       GISO, §6059
  Dive Procedures          GISO, §6060
    Post Dive Procedures       GISO, §6062
    Specific Operations       GISO, §6061
  Equipment Requirements       GISO, §6063
  Hyperbaric Conditions, Restrict of Limit Exposure     GISO, §6063, Appx A
  Post Dive Procedures         GISO, §6062
DIVING OPERATIONS, Scientific Purposes       GISO, §6063, Appx B
DIVINYL BENZENE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DIVISION of OCCUPATIONAL SAFETY & HEALTH (Cal/OSHA) See Cal/OSHA Web Page  
  Reporting             
     Accident Reporting, Injury & Fatality   See Cal/OSHA, §342  
    Actinolite Non-Asbestiform exposure to    GISO, §5208.1(l) 
    Aerial passenger tramways      
      Injuries        PARSO, §3154
      Inspections        PARSO, §3153
    Air tanks       See AIR TANKS  
    Amusement Ride Accident     GISO, §3920
    Anhydrous ammonia tanks, Repairs to  See Cal/OSHA, §512(f)  
    Anthophylite, Non-Asbestiform, exposure   GISO, §5208.1(l)
    Asbestos Use        
      Per CSO       CSO, §1529(r)
      Per GISO       GISO, § 5208(o)
      Per SSO        SSO, § 8358(q)
    Blasting accidents       GISO, §5248 
    Blasting Activities, per CSO     CSO, §1906(a)
    Boilers         B&FPV, §770(b)(3)
      Local Inspection In Lieu of Division Inspection B&FPV, §774(a)(1)
      Secondhand Power boilers   B&FPV, §767
    Butadiene         GISO, §5203
    Cadmium       See CADMIUM  
    Carcinogens     See CARCINOGENS & under Chemical Name
    Carcinogen Report of Use Requirements   GISO, §5203
      Accident/Incident reporting    GISO, §5203(f) 
      Incidents /Emergency reporting    GISO, §5203(f) 
      Posting of report     GISO, §5203(g)
      Report of Use     GISO, §5203(d)
      Temporary worksites     GISO, §5203(e)
      Use requiring reporting     GISO, §5203(c)
    Compressed natural gas Tanks, Welded Piping or Welded Vaporizers  
      Alteration & Repair     UFPV, §526(f)
    Dichloromethane, Methylene Chloride (MC), Carcinogen Use Reporting GISO, §5203
    Explosives, Manufacturing Operations    GISO, §5320 
    Fatalities & Serious Injuries    See Cal/OSHA, §342  
    Fatality, per TSO        TSO, §8420(c) 
    Incident Notification       MSO, §6960(a)
    Lead work, Notification of disposal of Records    GISO, §5198(n)(5)
      Notification of disposal of Records    CSO, §1532.1(n)(6)
    Liquefied Natural Gas, Tanks, Welded Piping or Welded Vaporizers  
      Alteration & Repair     UFPV, §526
    Methylene Chloride, Carcinogen Use Reporting   GISO, §5203
    Methylenedianiline, Carcinogen Use Reporting   GISO, §5203
    Mining Operations        
      Conditions, Unsafe, reporting to Employer   MSO, §6965
      Incident, per MSO     MSO, §6960(a)
        Accident that increases Mining hazards MSO, §6960(a)(10)
        Accumulation of gas   MSO, §6960(a)(2)
        Approaching Mine working w/ Gas or Water MSO, §6960(a)(6)
        Crushing of Active Mine Workings MSO, §6960(a)(7)
        Fatality     MSO, §6960(a)(9)
        Fire     MSO, §6960(a)(1)
        Ground Instability   MSO, §6960(a)(8)
        Hoisting Equipment Breakage MSO, §6960(a)(3)
        Injury, Serious   MSO, §6960(a)(9)
        Inrush of Water, Serious   MSO, §6960(a)(5)
        Overwinding, Hoisting Equipment MSO, §6960(a)(4)
    Notification of Fatality, per TSO      TSO, §8420(c) 
    Poster, Cal/OSHA     See Cal/OSHA, §340  
    Pressurized Worksite Operations     GISO, §6075(a)
    Tremolite, Non-Asbestiform, Exposure    GISO, §5208.1(l)
    Tunneling Operations        
      Fatality       TSO, §8420(c) 
       Tunnel Classifications     TSO, §8422(a)
        Reclassification    TSO, §8422(e)
DOCK PLATES & LOADING RAMPS       GISO, §3337
DOCKS, Marine terminal operations          GISO, §3465
"             "              "             "              "       See also MARINE TERMINAL OPERATIONS 
DOCTORS           See PHYSICIANS  
DODGE-EM RIDES, Amusement Rides       GISO, §3907(b)
DOLLIE, Hand            GISO, §3315
DOORS & DOORWAYS        See also EXITS  
  Entry           GISO, §3235
  Hoists, personnel         CSO, §1604.6
  Places of Employment, at       GISO, §3235
  Cargo Doors         GISO, §3323
  Tele-Communication Operations, per TelSO     TelSO, §8602(d)
  Unlocked            GISO, §3235(e)
DOOR LOCKS, Operable From Both Sides       GISO, §4536
DOT, Placards, Labels, Markings         GISO, §5194.1
  Truck Transport         GISO, §5270
DOUBLE CONNECTIONS, Structural Steel, Illustrations     CSO, §1710, Appx B
DOUBLE CLEAT LADDER         CSO, §1504(B)
DOUBLERS (Sliver & Ribbon Lap Machines)       GISO, §4469
DOUGH BRAKE, Food Service          GISO, §4544
DRAGLINES, Shovels & Loading Devices       MSO, §7012
  Parts Subject to Wear          MSO, §7011
    Inspection Requirement       MSO, §7011(a)
    Inspection Reports, Cal/OSHA Mandated   MSO, §7011(b)
    Intervals of Inspections       MSO, §7011(c)
DRAIN, Discharge Locations         GISO, §3310
DRAINAGE, Of Hazardous Substances, per PSO-R,T&H      PSO-R,T&H, §6828
DRAINAGE, Control            
  Aboveground Tanks, per GISO        GISO, §5595(a) 
  Aboveground Tanks, per PSO-D&P        PSO-D&P §6548 
  Aboveground Tanks, per PSO-R,T&H       PSO-R,T&H, §6805(a)
  Inside Buildings          GISO, §3309
  Oil, Oil Water Mixture, Haz-Waste, Collection Sumps, Pits, Ponds PSOD&P, §6538
  Storage Tanks         GISO, §5595(a) 
DRAINAGE SUMPS, Pits, Ponds for Oil Collection       PSO-D&P, §6538 
DRAPES, Decorative Materials         GISO, §3217
DRAWING FRAMES, Textile Machinery        GISO, §4459
DRESSING ROOMS, per TSO         TSO, §8431
DRILLING, Use of Drilling Equipment, per GISO       GISO, §3322
DRILLING, General Requirements, per TSO       TSO, §8449
  Use of Jumbos in Tunneling operations     TSO, §8450
DRILLING OPERATIONS, Rock, per CSO       CSO, §1538
DRILLING OPERATIONS, Mining Operations       MSO, §7005
    See Also MINING  
DRILLING & WELL SERVICING, Oil & Gas Wells, per PSO     PSO-D&P, Article 35
  Application / Scope         PSO-D&P, §6621
  Brakes & Brake Control Mechanism       PSO-D&P, §6626
  Catheads            PSO-D&P, §6642 
    Chain Used for Spinning Lines      PSO-D&P, §6645
    Lines Used on Catheads       PSO-D&P, §6644
  Drilling Equipment, Construction & Maintenance     PSO-D&P, §6624
  Emergency Stop Device         PSO-D&P, §6625
  Guarding           PSO-D&P, §6622
  Illumination / Lighting         PSO-D&P, §6657
  Line Spoolers & Deadline Stabilizers       PSO-D&P, §6688
  Power Tongs Control Mechanism       PSO-D&P, §6628
  Hose, Rotary Hose & Circulating & Standpipe     PSO-D&P, §6609
  Safety Provisions & Precautions        PSO-D&P, §6655
  Weight Indicators for Wire Rope Hoisting Lines     PSO-D&P, §6690
  Well Servicing Equipment, Construction & Maintenance   PSO-D&P, §6624
DRILLS           See also TOOLS & HAND TOOLS
  Grounding, Electrical, Cord- & Plug-connected      ESO-LV, §2395.45(a)
DRINKING WATER, Requirements          GISO, §3363
  Agricultural Operations, For       GISO, §3457(c)(1)
    Access to Drinking Water     GISO, §3395(c)
      Maintenance of     GISO, §3457(c)(3)
    Heat Illness Prevention       GISO, §3395(c)
    Maintenance of       GISO, §3457(c)(3)
  Potable Water in Adequate Supply       GISO, §3363(a)
  Clean & Sanitary         GISO, §3363(b)
  Common use, Prohibition       GISO, §3363(e)
  Construction Operations         CSO, §1524
    Common Drinking Cups / Containers     CSO, §1524(a)(5)
    Drinking Water        CSO, §1524(a)
    Non-Potable Water       CSO, §1524(b)
      Backflow Protection     CSO, §1524(b)(3)
      Posting at Outlet     CSO, §1524(b)(2)
      Prohibition of Use     CSO, §1524(b)(1)
  Cups, Drinking         GISO, §3457(c)
  Dipping or Pouring of, Prohibition       GISO, §3363(d)
  Dispenser, Designs & Construction       GISO, §3363(c)
  Drinking Supply, Not in Toilet Rooms       GISO, §3363(b)
    Fountains         GISO, §3363(b)
    Portable dispensers       GISO, §3363(c)
  Heat Illness Prevention         GISO, §3395
  Labor Camps, In          GISO, §3363
    Maintenance of Supply & Dispenser     GISO, §3363(b)
    Portable dispensers, use       GISO, §3363(c)
  Mining Operations         MSO, §6975
  Non-potable Water use for, Prohibition     GISO, §3363(f)
    Posting / Labeling, Non-potable Water   GISO, §3363(g)
    Backflow Prevention, Non-potable Water   GISO, §3363(h)
  Outside Work Locations, per GISO       GISO, §3395
  Pouring or Dipping of, Prohibition       GISO, §3363(d)
  Tunneling Operations         TSO, §8432
DRIVERS LICENSE            GISO, §3701
  Logging Trucks, Operating       LSSO, §6336(a)
  Farm labor vehicles, Operating       GISO, §3701(a)
  Transporting Employees         GISO, §3701(b)
DRIVERS TRAINING            
  Logging Truck Operators       LSSO, §6336(b)
DRIVE SHAFT, Guarding          GISO, §4050(a)
DRIVEWAYS            
  De-icing and snow melting equipment, Disconnect     ESO-LV, §2526.50
DRIVING, PILE            CSO, §1600
  Access Pits           CSO, §1600(r)
  Access to Pile Leads         CSO, §1600(f)
  Access to Sheet Piles         CSO, §1600(g)
  Blocking Device         CSO, §1600(b)
  Confined Space Entry per     Section 5158     CSO, §1600(r), Note
  Control Valves         CSO, §1600(c)(2)
  Danger Zone         CSO, §1600(a)
  Deck Engines         CSO, §1600(m)
  Extracting of  piles         CSO, §1601(b)
  Guardrails / Guard-lines         CSO, §1600(d)
  Hand Signals, Recommended in Plate C-11     CSO, §1600(l)
  Hoist Drums         CSO, §1600(n)
  Hoisting of Piles/Piling         CSO, §1600(p)(3), (s) & (t)
  Inspection Requirements, Pile Hammer       CSO, §1600(i)(1)
  Jacked Piles         CSO, §1600(r)
  Ladder Access          CSO, §1600(g)
  Leads, Access to          CSO, §1600(d) & (f)
  Leads, General Requirements       CSO, §1600(o)
  Lifesaving Boats, per  Article 13       CSO, §1600(j) & (k)
  Lockout/Blockout         CSO, §1600(b), (f)(2) & (n)
  Pile Driving Requirements       CSO, §1600(h)
  Pile Gates           CSO, §1600(o)(4)
  Pile Hammer Requirements       CSO, §1600(i)
  Platforms           CSO, §1600(d)
  Precautions, Ensure from falling       CSO, §1600(e)
  Pressurized Lines & Hoses       CSO, §1600(c)
  Ring Buoys, Water Safety       CSO, §1600(j) & (k)
  Securing the Hammer, Effective Blocking      CSO, §1600(b)
  Sheet Pile Access         CSO, §1600(g)
  Signaler, Designated         CSO, §1600(l)
  Stability of Pile Driving Rig        CSO, §1600(p)
  Steam Lines & Hoses         CSO, §1600(c)
  Stirrups, Employee Access to Sheet Piles     CSO, §1600(g)
  Storing piles         CSO, §1601
  Taglines, controlling unguided piles & free hanging hammers   CSO, §1600(t)
  Toeboards per    Section 1621(b)       CSO, §1600(e)
  Tube (Pipe) Piles, Blown out       CSO, §1600(q)
  Unloading piles         CSO, §1601
  Valves, Pressurized Steam & Air Line Controls     CSO, §1600(c)
  Water Safety         CSO, §1600(j) & (k)
DROP LINES, Fall Protection, for Workers        CSO, §1670(b)
  Lanyard, Safety belt, harness, prohibitions     CSO, §1670(h)
DROPS, Decorative Materials         GISO, §3217
DROWNING HAZARD, Work Over or Near Water        
  Agricultural Operations         GISO, §3448
  Construction Operations, per CSO        
    Access to or From Wharves, Floats, Barges, and/or Boats CSO, §1603
      Cat Walks, Ramps, Gangways, etc   CSO, §1603(e)
      Hand Rail       CSO, §1603(e)
      Illumination       CSO, §1603(g)
      Ladder to surface of Water, Water Safety CSO, §1602(a)(4)
      Jacob's Ladder (Chain Ladder/ Rope)   CSO, §1603(h), & (i)
    Barges, Access Ramp, Adequate Strength   CSO, §1603(a)
    Barges, Fixed Ladder to surface of Water, Water Safety CSO, §1602(a)(4)
    Catwalks over Water       CSO, §1603(b)
    Drowning Danger        CSO, §1602(a)
    Fall Protection Measures       CSO, §1602(a)
    First Aid/ Medical Assistance     CSO, §1602(b)
    Ladder to surface of Water, Water Safety   CSO, §1602(a)(4)
    Life lines, Tag lines       CSO, §1602(a)(3)
    Life Preservers, Control of Drowning Hazard per CSO  CSO, §1602 
    Lifesaving Boats        CSO, §1602(a)(3)
    Personal Flotation Devices (PFD)     CSO, §1602(a)(1)
    Pile Driving Water Safety       CSO, §1600(j) & (k)
      Lifesaving Boats, per  Article 13   CSO, §1600(j)
      Ring Buoys       CSO, §1600(j) & (k)
    Platforms over Water       CSO, §1603(d)
    Railings   per CSO, §1620      CSO, §1603(d)
    Ring Buoys         CSO, §1602(a)(2)
    Walkways, Dredge Discharge Pipe Lines use as   CSO, §1603(a)
  General Requirements, per GISO       GISO, §3389
  Life Preservers, per GISO        GISO, §3389
    Approval of, Coast Guard     GISO, §3389(b)
    Floating Cranes/Derrick operations, During   GISO, §4944
    Life Rings         GISO, §3389
    Maintenance of       GISO, §3389(c)
    Removal from Service when Damaged     GISO, §3389(c)
  Life Preservers, per CSO         CSO, §1602 
    Drowning Danger        CSO, §1602(a)
    Exception, w/ Fall Protection Measures   CSO, §1602(a)
    Life lines, Tag lines       CSO, §1602(a)(3)
    Lifesaving Boats        CSO, §1602(a)(3)
    Personal Flotation Devices (PFD)     CSO, §1602(a)(1)
    Ring Buoys         CSO, §1602(a)(2) 
  Mining Operations, per MSO        MSO, §6980(a)
  Paper, Pulp & Paperboard Mills       GISO, §3448
  Tunneling Operations, per TSO        TSO, §8427
DRUGS, NARCOTICS            
  Drugs & Alcohol Prohibited at Mining Operations     MSO, §6973(c)
  Drugs & Alcohol Handling or Use Prohibited at Blasting or Pyrotechnic Operations GISO, §5247(b)
DRUM SANDER, Woodworking          GISO, §4314
DRUNKEN SAW, Wobble Saw, Woodworking       GISO, §4323
DRY CLEANING & LAUNDRY EQUIPMENT        GISO, Article 67
  Boilers           GISO, §4493
  Clothes Tumbler, Shaker, Batch Type       GISO, §4486
  Dampening Machines         GISO, §4488
  Drying Box, Cabinet         GISO, §4487
  Drying Tumblers         GISO, §4485
  Extractors           GISO, §4482
  Ironer, Flatwork Type         GISO, §4489
    Body Type         GISO, §4490
    Press Type         GISO, §4492
    Rotary Type       GISO, §4491
  Marking Machine         GISO, §4480
  Operating Rules         GISO, §4494
  Pressure Vessels         GISO, §4493
  Shaker, Batch Type Tumblers       GISO, §4486
  Washing Machines         GISO, §4481
  Wringers, Power         GISO, §4483
DRYERS, Electrical grounding         ESO-LV, §2395.45 
DRYING CANS           GISO, §4472
DRYING FACILITIES, Clothing, per TSO        TSO, §8431
DUMBWAITERS, Electrical Requirements       ElevSO, §3112
    See also under ELEVATORS   
  Application / Scope         ESO-LV, §2562.1
  Controllers, Motor       See also under ELEVATORS ESO-LV, §2562.7 
  Disconnecting Means         ESO-LV, §2562.2
    Identification, Sign Requirements     ESO-LV, §2562.3
  Interconnection, Multicar Controllers       ESO-LV, §2562.6
  Motor Controllers         ESO-LV, §2562.7
  Sign Requirements         ESO-LV, §2562.3 
  Single-Car & Multicar Installations       ESO-LV, §2562.4
    Multiple Driving Machines     ESO-LV, §2562.3
    Multiple Disconnecting Means     ESO-LV, §2562.5
    Multicar Controllers       ESO-LV, §2562.6
    Warning Signs        ESO-LV, §2562.5
DUMP, Log Dump           LSSO, §6340
DUMP-BINS, Food Service         GISO, §4531
DUMPING, Loading & Hauling, per MSO       MSO, §7010
  Parts Subject to Wear          MSO, §7011
DUMPING, Locations, Surface & Underground, per TSO     TSO, §8480
DUMP TRUCKS, Control of Hazardous Energy during Repair, per CSO   CSO, §1595(b) 
DURSBAN, Airborne Contaminant, Exposure limit        GISO, §5155, & Appx A
  Listed, Permissible Exposure Limits       GISO, §5155, Table AC-1
DUST, Control of, per CSO       See also DUSTS, FUMES, MISTS, VAPORS & GASES, per CSO
  Haulage, Earthmoving, to Maintain Visibility     CSO, §1590(d) 
  Respiratory Protection, During Dusty Operations     CSO, §1590(d) 
DUST, Control of, per MSO           
  Dust, Smoke & Gases after Blasting       MSO, §7095
  Dust, Smoke & Gases, Secondary Blasting     MSO, §7096
  Mechanical Ventilation         MSO, §7099
  Mine Ventilation         MSO, §7098
  Mucking & Transferring Rock       MSO, §7094
  Mucking & Transferring Rock, Dust Control     MSO, §7094
  Radiation Hazards, Underground       MSO, §7091
  Rock Drilling, Dust Control       MSO, §7093
  Rock Drilling Requirements       MSO, §7093
  While Drilling         MSO, §7092
DUST, Control of, per PSO-R,T&H          PSO-R,T&H, §6788
DUST, Control of, per TSO         TSO, §8438
DUST, Suppression of           GISO, §5145
DUSTS, FUMES, MISTS, VAPORS & GASES, per CSO     CSO, Article 4
  Dusts Control at Worksite       CSO, §1528
  Dust Exposure, Concrete / Masonry Operations      CSO, §1530.1
  Exhaust systems         CSO, §1530
  Flammable Vapors, Control of        CSO, §1534
  General requirements          CSO, §1528
  Internal combustion engines        CSO, §1533
  Mechanical ventilation systems        CSO, §1530
  Respiratory protective equipment       CSO, §1531
  Rock Drilling Operations         CSO, §1538
DUST, Control of, per GISO       See also DUSTS, FUMES, MISTS, VAPORS & GASES, per GISO
  Combustible Dust         GISO, §5174
  Control of, General         GISO, §5145
  Cotton dust        See COTTON DUST  
  Harmful exposure         GISO, Article 107
    Control of         GISO, §5141
    HVAC Systems       GISO, §5142
    Mechanical ventilation Systems     GISO, §5143
    Respiratory Protection          GISO, §5144
    Exposure limit       GISO, §5155, & Appx A
    Listed, Permissible Exposure Limits     GISO, §5155, Table AC-1
  Woodworking, dust collection systems     GISO, §4324
DUSTS, FUMES, MISTS, VAPORS & GASES, per GISO     GISO, Article 107
    Application / Purpose       GISO, §5139
    Definitions          GISO, §5140
  Abrasive Blasting Operations, Protective Equipment    
    Ventilation & Personal Protection     GISO, §5151
      Abrasives, Organic      GISO, §5151(c)
      Enclosures, Blast-Cleaning   GISO, §5151(a)
      Personal Protective Equipment    GISO, §5151(b)
  Administrative Controls of harmful exposure      GISO, §5141
  Airborne Contaminants         GISO, §5155, & Appx A
      Application / Scope     GISO, §5155(a)
      Definitions       GISO, §5155(b)
    Ceiling Limits       GISO, §5155(c)(3)
    Exposure Computations       GISO, §5155, Appx A
    Exposure Limits       GISO, §5155(c)
      Permissible Exposure Limits   GISO, §5155(c)(1)
      Short Term Limits     GISO, §5155(c)(2)
    Listed, Permissible Exposure Limits     GISO, §5155, Table AC-1
    Medical Surveillance       GISO, §5155(f)
    Monitoring, Workplace       GISO, §5155(e)
    Permissible Exposure Limits     GISO, §5155(c)(1)
      For Chemical Contaminants, Listed   GISO, §5155, Appx A, Table AC-1 & Foot Notes
    Skin Absorption, Protection Against     GISO, §5155(d)
  Biological Safety Cabinets        
    Ventilation Requirements       GISO, §5154.2
        Application / Scope   GISO, §5154.2(a)
        Definitions     GISO, §5154.2(b)
      Air Flow Measurements     GISO, §5154.2(f)
      Appendices       GISO, §5154.2(h)
      HEPA Filter Aerosol Test Protocol   GISO, §5154.2, Appx A
      HEPA Filter Leak Testing     GISO, §5154.2(f)
      Implementation     GISO, §5154.2(i)
      Negative Pressure Requirements   GISO, §5154.2(e)
      Operation Requirements     GISO, §5154.2(d)
      Special Requirements     GISO, §5154.2(g)
      Start Up & Shut Down Procedure    GISO, §5154.2, Appx B
      Use Requirements     GISO, §5154.2(c)
      Ventilation Rates     GISO, §5154.2(e)
  Buffing Operations, Protective Equipment   See Grinding, Polishing & Buffing Operations under this heading
  Building Ventilation, Mechanical Heating & Cooling   GISO, §5142
    System Requirements       GISO, §5143
  Chemicals Contaminants, Exposure Limits      GISO, §5155, Appx A
  Chemicals, Harmful, Suppress & Allay      GISO, §5145
  Combustible Dust         GISO, §5174
  Control of Harmful Exposure to Employees     GISO, §5141
  Dipping / Immersion Tanks, Open-Surface       
    Ventilation & Personal Protective Equipment   GISO, §5154
      Application       GISO, §5154(a)
      Classification of Tanks     GISO, §5154(b)
        Hazard Determination   GISO, §5154, Table V-7
        Vapor & Gas Evolution Rate  GISO, §5154, Table V-8
        Cleaning Equipment, Spray GISO, §5154(i)
      Control Methods, Other     GISO, §5154(g)
      Control Requirements     GISO, §5154(c)
        Velocity, Control   GISO, §5154, Table V-9
      Degreasing Equipment, Vapor   GISO, §5154(h)
      Degreasing Equipment, Spray   GISO, §5154(i)
      Hood Classification     GISO, §5154(d)
      Push-Pull System Requirements   GISO, §5154(f)
      Personal Protective Equipment    GISO, §5154(j)
      Ventilation Rate     GISO, §5154(e)
  Dust Suppression         GISO, §5145
  Emergency Eye wash & Shower Equipment   See also EYEWASH GISO, §5162
  Engineering Controls, to Prevent harmful Exposure      GISO, §5141
  Grinding, Polishing & Buffing Operations      
    Ventilation & Personal Protective Equipment   GISO, §5152
      Branch Duct Performance Requirements GISO, §5152(b)
      Buffing Operation     GISO, §5152(d)
      Exhaust Volume     GISO, §5152, Tables V-1 through V-5
      Hood or Enclosure Requirement   GISO, §5152(a)
      Hood Performance Requirements   GISO, §5152(b)
      Hood Design     GISO, §5152(c)
      Hoods, Illustrations     GISO, §5152, FiguresV-1 through V-8
      Portable Grinder & Polishers   GISO, §5152(d)
    HVAC, Building Ventilation     GISO, §5142
      System Requirements     GISO, §5143
    Indoor Air Quality, HVAC Systems     GISO, §5142
  Harmful Exposure, Control       GISO, §5141
  Hazard communication program      See HAZARD COMMUNICATION PROGRAM
  HVAC Systems, Minimum Ventilation Requirements   GISO, §5142
  Internal Combustion Engine, Emission Control     GISO, §5146
  Laboratory-Type Hoods Operations       GISO, §5154.1
    Ventilation Requirements       GISO, §5154.1
        Application / Scope   GISO, §5154.1(a)
        Definitions     GISO, §5154.1(b)
      Operation Requirements     GISO, §5154.1(d)
      Operator Qualifications     GISO, §5154.1(f)
      Special Requirements     GISO, §5154.1(e)
      Ventilation Rates     GISO, §5154.1(c)
  Mechanical ventilation systems        GISO, §5143
  Media for Allaying Hazards       GISO, §5145
  Oil to suppress Hazard          GISO, §5145
  Open Vats & Tanks, including Dipping & Coating Operations    
    Ventilation & Allaying Media, used to Control Hazards GISO, §5154
  Oxygen Deficiency          GISO, §5149
  Polishing Operations, Protective Equipment    See Grinding, Polishing & Buffing Operations under this Heading
  Respirators, Respiratory Protection        GISO, §5144
      Definitions       GISO, §5144(b)
    Air, Quality & Use Breathing Air     GISO, §5144(i)
    Abrasive blasting        GISO, §5151
    Buffing Operations       GISO, §5152
    Canisters, Filters & Cartridges Identification   GISO, §5144(j)
    Cartridges, Filters & Canisters, Identification   GISO, §5144(j)
    Cleaning & Disinfecting of Respirators   GISO, §5144(h)(1)
      Respirator Cleaning Procedure   GISO, §5144, Appx B-2
    Employee Information Requirement     GISO, §5144, Appx D
    Evaluation of Respiratory Protection Program   GISO, §5144(l)
    Filters, Cartridges & Canisters, Identification   GISO, §5144(j)
    Fit Testing         GISO, §5144(f)
    Fit Testing Procedure       GISO, §5144, Appx A
    Grinding Operations       GISO, §5152
    Inspection of Respirators       GISO, §5144(h)(3)
    Instructions & Training, Employee      GISO, §5144, Appx D
    Medical Evaluation       GISO, §5144(e)
    Medical Evaluation Questionnaire     GISO, §5144, Appx C
    Maintenance & Care of Respirators     GISO, §5144(h)
    Open-surface tank operations      GISO, §5154
    Oxygen deficient environments      GISO, §5149
    Polishing Operations       GISO, §5152
    Protection Factors, Assigned     GISO, §5144, Table 1
    Record keeping        GISO, §5144(m)
    Repair of Respirators       GISO, §5144(h)(4)
      Permissible Practice     GISO, §5144(a)
    Respiratory Protection Program Requirements   GISO, §5144(c)
      Evaluation of Program     GISO, §5144(g)
    Respirator Cleaning Procedure     GISO, §5144, Appx B-2
    Respirator Selection       GISO, §5144(d)
    Seal Check Procedure       GISO, §5144, Appx B-1
    Spray coating operations      GISO, §5153
    Storage of Respirators       GISO, §5144(h)(2)
    Training & Information       GISO, §5144(k)
    Use of Respirators, Procedure     GISO, §5144(g)
    Welding cutting and brazing      GISO, §5150
  Smoking, Prohibition in the Workplace     GISO, §5148
  Spray Coating Operations        
    Ventilation & Personal Protective Equipment   GISO, §5153
      Spray Booth / Room, In     GISO, §5153(a)
      Spray Operation Requirements   GISO, §5153(b)
      Exhaust Air       GISO, §5153(c)
      Make-up Air     GISO, §5153(c)
      Dilution of Flammable Vapors   GISO, §5153(d)
      Ventilation Rate     GISO, §5153(e)
      Downdraft Booths     GISO, §5153(f)
      Respiratory Protection     GISO, §5153(g)
  Suppression of Dusts, Fumes, Mists, Vapors & Gases   GISO, §5145 
  Tuberculosis, Respiratory Protection from     GISO, §5147
  Ventilation, Minimum Building Ventilation      GISO, §5142
    System Requirements       GISO, §5143 
      Spray Booth / Room, In     GISO, §5153(a)
      Spray Operation Requirements   GISO, §5153(b)
      Exhaust Air       GISO, §5153(c)
      Make-up Air     GISO, §5153(c)
      Dilution of Flammable Vapors   GISO, §5153(d)
      Ventilation Rate     GISO, §5153(e)
      Downdraft Booths     GISO, §5153(f)
      Respiratory Protection     GISO, §5153(g)
  Water to suppress Dust         GISO, §5145 
  Welding, Brazing & Cutting, Protective Equipment      
    Ventilation & Personal Protection     GISO, §5150
      Chlorinated Hydrocarbons   GISO, §5150(e)
      Improper Use of Welding Gases   GISO, §5150(d)
      Labeling, Precautionary     GISO, §5150(f)
      Mechanical Ventilation, Indoors   GISO, §5150(a)
      Toxic Substances Used in Enclosed Spaces GISO, §5150(b)
      Toxic Substances Used in Open Air   GISO, §5150(c)
DUST COLLECTION SYSTEMS, Woodworking       GISO, §4324
DUST, Combustible            GISO, §5174
DYE JIGS             GISO, §4471
DYFONATE, Airborne Contaminant, Exposure limit      GISO, §5155, & Appx A
    Listed, Permissible Exposure Limits     GISO, §5155, Table AC-1
DYNAMITE         See EXPLOSIVES