A List of Acronyms
ABATE
Correcting Unsafe Conditions GISO, §3203(a)(6)
Hazardous Waste Operations See under HAZARDOUS WASTE OPERATIONS & Emergency Response
ABOVEGROUND STORAGE TANKS See also under TANKS 
Aboveground Tanks, per GISO
Drainage, Dikes & Walls for  GISO, §5595 
Emergency Relief Venting, Fire Exposure GISO, §5593 
Capacity of GISO, §5593, Table FL-16 & FL-17
Location of with Respect to Buildings GISO, §5591
Outside Installation GISO, §5589
Retaining Walls for  GISO, §5595 
Spacing between Tanks GISO, §5590 
Tank Openings Other Than Vents GISO, §5596 
Venting for Aboveground Tanks  GISO, §5592
Venting, Capacity of GISO, §5593, Table FL-16 & FL-17
Vent Piping for Aboveground Tanks GISO, §5594 
Aboveground Tanks, per PSO-R,T&H
Anchorage, Supports & Foundations for PSO-R,T&H, §6809
Drainage, Dikes & Walls for Above Ground Tanks PSO-R,T&H, §6805
Installation of Tanks Inside Buildings PSO-R,T&H, §6808
Tank Openings for Above Ground Tanks PSO-R,T&H, §6806
Aboveground Tanks, per PSO-D&P
Drainage, Dikes & Walls  PSO-D&P, §6548
Aboveground Tanks, per UFPV
Liquefied Petroleum Gas (LPG) UFPV, §477(a), (b)
ABRADING MACHINES, Metal Work, (Class A) See under METAL WORKING MACHINES
ABRASIVE BLASTING OPERATIONS
Automatic systems required for Organic Abrasives GISO, §5151(c)
Enclosures, Blast-Cleaning GISO, §5151(a)
Nozzle, Manual Valve GISO, §3301(d)
Nozzle Support, when unused GISO, §3301(d)
Organic Abrasives, combustible GISO, §5151(c)
Personal Protective Equipment GISO, §3301(c)
                                                   GISO, §5151(b)
Protective Equipment
Ventilation & Personal Protection GISO, §5151
Abrasives, Organic  GISO, §5151(c)
Enclosures, Blast-Cleaning GISO, §5151(a)
Personal Protective Equipment  GISO, §5151(b)
Respiratory Protection GISO, §5151(b)
ABRASIVE WHEELS, Use, Care, & Protection GISO, Article 21  
Application, Scope & Definitions GISO, §3575
Abrasive Wheels, Portable  GISO, §3583
Exposure to wheel GISO, §3578, Appx A, B, E
Flanges, General Requirements GISO, §3579, Appx A, 
Flanges, Portable Abrasive Wheels GISO, §3583, Tables
Examples (Illustrations) GISO, §3583, Appx C, D
Grinding Machine Requirements, General Requirements GISO, §3576
Guarding of GISO, §3577(b), Appx F, G
Hoods, Protective GISO, §3577(b), (c)
Illustrations GISO, §3583, Appx A - G 
Inspection of GISO, §3580(a)
Mounting Flanges GISO, §3579, Appx A  
Mounting of GISO, §3580
Portable Abrasive Wheels GISO, §3583
Portable Grinders  GISO, §3576(b)
Protection Devices GISO, §3577
Speed
At Safe Speeds, Per Design, Machine & Equipment Requirement GISO, §3328(a)
Check Design Speed of Wheel before Mounting GISO, §3580(a)
Check Design Speed of Portable Abrasive Wheel before Mounting GISO, §3583(f)
Maximum Wheel Speed  GISO, §3583(f), Table A-6
Stationary Grinders GISO, §3576(a)
Storage of Wheels GISO, §3582
Ventilation & Personal Protective Equipment GISO, §5152
Branch Duct Performance Requirements GISO, §5152(b)
Exhaust Volume GISO, §5152, Tables V-1 through V-5
Hood or Enclosure Requirements GISO, §5152(a)
Hood Performance Requirements GISO, §5152(b)
Hood Design GISO, §5152(c)
Hoods, Illustrations GISO, §5152, Figures V-1 through V-8
Portable Grinder & Polishers GISO, §5152(d)
Wheel Exposure, Permissible  GISO, §3578
Wheel Mounting  GISO, §3580
ACCESS, to Work Locations ESO-HV, §2940(a)
Electrical Controls, Panels, Switches, etc ESO-HV, §2711 
ACCESS, Work Space / Structures
Access, General Requirements GISO, §3270
Use of Rope Access Equipment GISO, §3270.1
Openings, Attic, Ceiling & Underfloor Spaces GISO, §3271
Aisles, Walkways & Crawlways GISO, §3272
Attic, Access Openings GISO, §3271
Bleachers  GISO, §3239
Ceiling, Access Openings GISO, §3271
Construction Work locations CSO, §2940
Crawlways, Aisles & Walkways GISO, §3272 
Crane & Derrick Suspended Personnel Platforms GISO, §5004
Application GISO, §5004(a)
Design Criteria GISO, §5004(f)
Exception to Prohibited Use GISO, §5004(a)
Free Fall Prohibition GISO, §5004(e)
Instrument & Component Requirements GISO, §5004(e)
Loading Requirements GISO, §5004(h)
Operating Criteria GISO, §5004(d)
Pre-Lift Meeting GISO, §5004(m)
Rigging of GISO, §5004(i)
Scope of §5004 GISO, §5004(a)
Specifications GISO, §5004(g)
Traveling of Hoist or Crane GISO, §5004(l)
Trial Lift, Inspection & Proof Testing GISO, §5004(j)
Work Practices GISO, §5004(k)
Doors  GISO, §3235
Electrical Controls & Panels, etc ESO-HV, §2711
Exits
Access to Exits GISO, §3225
Arrangements & Distance to Exits GISO, §3222
Balconies serving as Exit GISO, §3226
Corridors serving as Exit GISO, §3226
Access to Corridors GISO, §3226(e)
Discharge from Exit GISO, §3227
Maintenance of GISO, §3225
Number of  GISO, §3228
Ramps, General Requirements GISO, §3232
Ramps, Industrial  GISO, §3233
Signs GISO, §3216 
Stairs, Fixed Industrial GISO, §3234
Stairways  GISO, §3231
Stands, Reviewing & Grandstands GISO, §3239 
Width of Exit GISO, §3229 
General Access Requirements
Access, Work Space & Areas GISO, §3270
Elevated Locations  GISO, §3210
Fixed Ladder  GISO, §3270
Servicing Machinery  GISO, §3270
Elevations  CSO, §1629(a)(3)
Exits GISO, §3225
Handicapped Access  See ELEVATORS, Special Access, Elevators & Lifts
High Piles of Material or Equipment GISO, §3339(b)
Rope Access Equipment, Use of GISO, §3270.1
High Piles GISO, §3339(b)
Ladders  See also LADDERS
Fixed Ladders GISO, §3277
Portable Ladders GISO, §3276
Manholes 
Construction Operations
Manholes & Floor Openings,  CSO, §1632
Design requirements of Covers CSO, §1597(k)
General Industry Requirements, per GISO GISO, §3213(d)
Telecommunication Operations, per TelSO
Entering Procedure TelSO, §8616(b)
Flames, Open, in Man Holes  TelSO, §8616(f)
Procedural Requirements TelSO, §8616(f)(1), (2)
Guarding TelSO, §8616(a)
Joint Power & Tele-com Man Holes TelSO, §8616(d)
First Aid Training  TelSO, §8616(d)
Attendant Duties TelSO, §8616(d)
Man Hole Platform TelSO, §8616(c) 
Underground Vaults, High-Voltage
Confined Space Regulations, Mandated ESO-HV, §2943(b)
Work in Manholes, Vaults, & Similar Structures ESO-HV, §2943(b)
Openings, to Attic, Ceiling & Underfloor Spaces GISO, §3271
Ropes Access GISO, §3270.1
Application & Scope GISO, §3270.1 (a)  
Anchorage  GISO, §3270.1 (e)
Emergency Search & Rescue Operations, Exception  GISO, §3270.1 (a)  
Entertainment Performances & Rehearsals, Exception  GISO, §3270.1 (a)  
Equipment Approval   GISO, §3270.1 (b)
Equipment Inspection   GISO, §3270.1 (d)
Exterior Building Maintenance, Exception  GISO, §3270.1 (a)  
Fall Protection Requirement  GISO, §3270.1 (j)
Maintenance  GISO, §3270.1 (d)
Personal Protective Equipment  GISO, §3270.1 (f)
Pre-Work briefing   GISO, §3270.1 (l)
Rescue, Prompt   GISO, §3270.1 (i)
Site Management, Precautions   GISO, §3270.1 (k) 
Supervision   GISO, §3270.1 (g)
Training   GISO, §3270.1 (c)
Trainer Qualifications  GISO, §3270.1 (h)
Window Cleaning, Exception GISO, §3270.1 (a)
Scaffolds, Suitable for Work Performed GISO, §3275
Stairways See STAIRWAYS
Suspended Personnel Platforms, Crane & Derrick Hoisted See Crane & Derrick Suspended Personnel Platforms in this Entry
Underfloor Space, Access Openings GISO, §3271
Valves & Controls, Safe Means of Access GISO, §3274
Walkways Aisles & Crawlways GISO, §3272
Working Area GISO, §3273
ACCESSIBLE SURFACE, Definition per SSO SSO, §8354
ACCESS & EGRESS, per CSO
Barges, Wharves, Floats, & Boats CSO, §1603
Access Ramp, Adequate Strength CSO, §1603(a)
Catwalks over Water CSO, §1603(b)
Ramp, Adequate Strength CSO, §1603(a) & (b)
Walkway CSO, §1603(b)
Access Ramp, Adequate Strength CSO, §1603(a)
Fixed Ladder to surface of Water, Water Safety CSO, §1602(a)(4)
Elevators, Temporary, per CSO See also PERSONNEL HOIST 
Elevators for Hoisting Workers CSO, §1630
Building Trigger Height CSO, §1630(a)
Use of permanent elevators during construction CSO, §1604.4
Excavations  CSO, §1541(c) 
Sheet Piles, During Pile Driving CSO, §1600(g)
Aerial Device CSO, §1600(g)(1)
Crane Suspended Personnel Platform CSO, §1600(g)(1)(B)
Ladder Access CSO, §1600(g)(1)
Stairways & Ladders  CSO, §1629
ACCESS & EGRESS, per ESO
Electrical Control Cabinets Access ESO-LV, §2561.3
ACCESS & EGRESS, per MSO
Unattended Mine Openings MSO, §7178(a), (c)
ACCESS & EGRESS, per PSO-D&P
  Oil & Gas Wells, Crown Platforms PSO-D&P, §6592(a)
ACCESS & EGRESS, per PSO-R,T&H PSO-R,T&H, Article 8
Buildings Access & Egress PSO-R,T&H, §6798
Egress Requirements for Equipment Structures PSO-R,T&H, §6799
Illumination / lighting pursuant to §3317, GISO PSO-R,T&H, §6800
ACCESS & EGRESS, per TSO TSO, §8411
Shaft & Inclines TSO, §8494
Mobile Equipment, Protected from, per TSO TSO, §8411(b)
Provided & Maintained, Safe Means  TSO, §8411(a)
Walkways, Clearly Designated & unobstructed TSO, §8411
Protected from Sumps, holes, excavations GISO, §3204(e)
ACCESS, Handicapped 
Lifts See ELEVATORS, Special Access, Elevators & Lifts
Special Access Elevators See ELEVATORS, Special Access, Elevators & Lifts
Stairway Chairlifts    See STAIRWAY CHAIR LIFTS
Wheelchair Lifts See ELEVATORS, Special Access, Elevators & Lifts
ACCESS TO, Records & Information 
Acutely hazardous substances  GISO, §5189, &, Appx A
Diving operations, injury records GISO, §6058 
Employee exposure records GISO, §3204
Exposure Records GISO, §3204(e)
Federal lead standard GISO, §5198, Appx B
Medical records GISO, §3204(e)
Occupational noise control records GISO, §5100
Process Safety Management  GISO, §5189, & Appx A
ACCESS TO SHIP MASTS & KING POST, Radiation Hazard SSO, §8397.5
ACCESS ZONES, CONTROLLED, Fall Protection CSO, §1671.2(a)
ACCIDENTS
Amusement rides
Cal/OSHA notification GISO, §3920
Permits, effect on GISO, §3915(b)
Blasting operations
Cal/OSHA Reporting  GISO, §5248(a),(b)
Electrical installations & Equipment 
Maintenance to prevent ESO-LV, §2340.1
Overhead high-voltage lines  ESO-HV, Article 37
General Provisions for Program ESO-HV, §2946
Notification to the Operators of High-Voltage Lines ESO-HV, §2948
Responsibility for Safeguards  ESO-HV, §2948
Special Exemption ESO-HV, §2949
Warning Signs Requirement ESO-HV, §2947 
Prevention tags ESO-LV, §2320.6
Prevention Program See INJURY & ILLNESS PREVENTION PROGRAM
Reporting, Cal/OSHA See Cal/OSHA, §342
Recording, Forms 300, 300A, 301  See CCR, Title 8, Chapter 7, §14300.29
Work stoppage GISO, §5248(c)
ACCIDENT PREVENTION PROGRAM See also INJURY & ILLNESS PREVENTION PROGRAM
Approved Danger Signs GISO, §3340(d)
Biological Hazard GISO, §3340(c)(5)
Color Coding of Tags GISO, §3341, Appx A
Construction Operations, per CSO CSO, §1509
Establish, Implement & Maintain CSO, §1509(a)
Code of Safe Practices CSO, §1509(b)
Posting of CSO, §1509(c)
Safety Meetings CSO, §1509(d), (e)
Criteria for Tags GISO, §3341(d)
Danger Signs GISO, §3340(c)(1)
Design of Sign GISO, §3340(d)
Electrical, Overhead Power Lines, Proximity to  ESO-HV, Article 37
General Provisions for Program ESO-HV, §2946
Notification to the Operators of High-Voltage Lines ESO-HV, §2948
Responsibility for Safeguards  ESO-HV, §2948
Special Exemption ESO-HV, §2949
Warning Signs Requirement ESO-HV, §2947 
Electrical Installations & Equipment, Maintenance to prevent Accidents ESO-LV, §2340.1
Accident Prevention tags ESO-LV, §2320.6
Industrial plants GISO, §3203
Laser, Warning signs
Construction Operations CSO, §1801(d)
Tunneling Operations TSO, §8416(b)
Lettering/Wording of Warning Signs GISO, §3340(d)(1), (e)
Logging & Sawmill Operations LSSO, §6250  
Marine terminal operations GISO, §3464
Mine Accident Prevention Program MSO, Article 4
Competent Person Requirement MSO, §6966
Reporting of Unsafe Conditions MSO, §6965
Safety Bulletin Board Requirements MSO, §6962
Safety Committee MSO, §6964
Safety Representatives, Certification of MSO, §6967
Safety Training & Instructions MSO, §6963
Supervision of Work & Employees MSO, §6966
Training & Instructions, Safety MSO, §6963
Petroleum production/drilling PSO-D&P, §6507
Petroleum refining, transportation, handling PSO-R,T&H, §6760
Ship building, repairing, & breaking    SSO, §8350
Signs GISO, §3340
Slow Moving Vehicle Emblem  GISO, §3340(d)(6)
Suggested program  SSO, §8399, Appx B
Symbol GISO, §3340(d)(7)
Tags GISO, §3341
Tree trimming, maintenance, or removal GISO, §3421
Warning, Automatic Start  GISO, §3320
Warning, High Voltage Lines ESO-HV, §2947
Tunnel operations TSO, §8406
Access, Safe TSO, §8411
Use of Tags, General  GISO, §3341(c)
Construction Operations CSO, §2320.6
Warning GISO, §3440(c)(2), (d)(2)
ACCIDENT PREVENTION SIGNS GISO, §3340
Application / Scope of §3340 GISO, §3340(a)
Definitions  GISO, §3340(b)
Agricultural Vehicle Sign, Slow Moving GISO, §3340(d)(6)
Classification of Signs by Use GISO, §3340(c)
Design of Signs GISO, §3340(d)
Wording on Signs GISO, §3340(e)
ACCIDENT PREVENTION TAGS GISO, §3341
Application / Scope of §3341 GISO, §3341(a)
Definitions  GISO, §3341(b)
Biological Hazard Tags GISO, §3341(h)
Caution Tags GISO, §3341(f)
Color Coding for Tags GISO, §3341, Appx A
Danger Tags GISO, §3341(e)
Design Criteria of Tags GISO, §3341(d)
Electrical Hazard Tags ESO-LV, §2320.6
Other Tags  GISO, §3341(i)
Use of Tags GISO, §3341(c)
Warning Tags GISO, §3341(g)
ACETALDEHYDE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Process Safety Management GISO, §5189, Appx A
ACETIC ACID, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETIC ANHYDRIDE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETONE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETONE CYANOHYDRIN, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETONITRILE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETOPHENONE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETYLAMINOFLUORENE, 2-Acetylaminofluorene See also CARCINOGENS, Specified
Carcinogen  GISO, §5209
Application & Scope GISO, §5209(a)
Change Room, Hygiene Facilities & Practices GISO, §5209(b), (d)
Container Content identification GISO, §5209(e)(2)
Definitions, For the purpose of §5209 GISO, §5209(b) 
Medical Surveillance GISO, §5209(g)
Examinations GISO, §5209(g)(1)
Records GISO, §5209(g)(2)
Regulated Areas  GISO, §5209(c)
Isolated Systems GISO, §5209(c)(1)
Closed System Operations  GISO, §5209(c)(2)
Open Vessel System Operations  GISO, §5209(c)(3)
Opening a Closed System  GISO, §5209(c)(4)
Maintenance & Decontamination  GISO, §5209(c)(5)
Laboratory Activities GISO, §5209(c)(6) 
Regulated Area, General Requirements GISO, §5209(d) 
Emergencies, Specific Procedures  GISO, §5209(d)(1)
Hygiene Facilities & Practices GISO, §5209(d)(2)
Contamination Control  GISO, §5209(d)(3)
Respirator program GISO, §5209(d)(4) 
Reports per §5203 GISO, §5209(f) 
Signs, Information & Training GISO, §5209(e) 
Signs GISO, §5209(e)(1) 
Container Contents Identification GISO, §5209(e)(2) 
Lettering on signs GISO, §5209(e)(3) 
Prohibited Statements, Information GISO, §5209(e)(4) 
Training & Indoctrination GISO, §5209(e)(5)
Training GISO, §5209(e)(5)   
Exposure limit, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETYLENE GENERATOR SYSTEMS  See also WELDING & CUTTING SYSTEMS, Gas
Approval  GISO, §4797(a)
Auxiliary apparatus  GISO, §4797(b)
Calcium Carbide
Storage GISO, §4818
Opening of containers GISO, §4819
General Requirements
Construction of Generators GISO, §4803
Marking / Labeling GISO, §4797
Rating & Pressure Limits of GISO, §4798
Training, Instructions, Operator  GISO, §4799
Hose piping CSO, §1743(d)
Installation GISO, §4797(c)
Operator training GISO, §4799
Permanent Stationary Acetylene Generators 
Drain Connections GISO, §4810
Exits for Houses / Compartments GISO, §4806
Freeze Protection for Generators GISO, §4808
Gas Holders GISO, §4813
Generator Escape or Relief Pipes GISO, §4811
Housing of Generators GISO, §4803
Houses, Outside  GISO, §4804
Inside Rooms / Compartments  GISO, §4805
Maintenance of GISO, §4812 
Operation Requirements of GISO, §4812 
Outside Houses / Compartments GISO, §4804
Ventilation in Houses / Compartments GISO, §4807
Water Supply Connections GISO, §4809
Portable Acetylene Generators 
General Requirements GISO, §4815
Operation & Maintenance Requirements GISO, §4816
Pressure limitations GISO, §4799 
Prohibited practices
Air mixing CSO, §1743(a)
Contact w/ oil, grease CSO, §1743(c)
Contact w/ unalloyed copper CSO, §1743(f)
Welding operations See WELDING & CUTTING, GAS SYSTEMS
ACETYLENE, OXYGEN, & FUEL GAS
Backflow Protector, Welding  GISO, §4845(b)
Connections & Hoses CSO, §1742
Manifold CSO, §1742(e)
Cylinders  GISO, §4650(d)
   CSO, §1743  
Electrical circuits, Prohibition CSO, §1740(e)
Construction of GISO, §4649(a), (b), (c) 
Hoisting of CSO, §1740(d)  
Leaking of CSO, §1740(m)  
Marking of GISO, §4649(d)
Protection CSO, §1740(c), (h), (i), (j)
Valve GISO, §4650(c)
Prohibitions CSO, §1743(h)
Storage CSO, §1740(b), (g) 
Transport/Handling CSO, §1740(c) 
Exposure limits, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
General Precautions      CSO, §1743
Hose & Connections  CSO, §1742
Manifold CSO, §1742(e)
Maximum Pressure CSO, §1743(b)
Pressure Regulators      CSO, §1741
Storage & Use of Cylinders      CSO, §1740
Transfer prohibited CSO, §1740(f)
Unalloyed copper contact with CSO, §1743(f)
Use of Cylinders      CSO, §1740 
ACETYLENE TETRABROMIDE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACETYLENE WELDING & CUTTING SYSTEMS See WELDING & CUTTING SYSTEMS, Gas
ACETYLSALICYLIC ACID, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACROLEIN, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A 
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Process Safety Management GISO, §5189, Appx A
ACRYLAMIDE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACRYLIC ACID, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ACRYLONITRILE GISO, §5213
See Also CARCINOGENS, Regulated
Application & Scope GISO, §5213(a)
Definitions  GISO, §5213(b)
Appendices, Application of   GISO, §5213(s)
Change Room  GISO, §5213(j), (l)
Emergencies  GISO, §5213(i)
Emergency Alarm  GISO, §5213(i)(2)
Emergencies, Reporting per §5203  GISO, §5213(d)
Written Procedures   GISO, §5213(i)(1)
Employee Information & Training  GISO, §5213(o)
Training Program   GISO, §5213(o)(1)
Access to Training Materials   GISO, §5213(o)(2)
Exposure Limits  GISO, §5213(c)
Permissible Exposure Limits -Inhalation  GISO, §5213(c)(1) 
Dermal & Eye Exposure   GISO, §5213(c)(2)
Exposure Monitoring  GISO, §5213(e)
General  GISO, §5213(e)(1)
Initial Monitoring   GISO, §5213(e)(2)
Frequency   GISO, §5213(e)(3)
Additional Monitoring  GISO, §5213(e)(4)
Employee Notification   GISO, §5213(e)(5)
Accuracy of Measurement  GISO, §5213(e)(6)  
Housekeeping  GISO, §5213(k)
Hygiene Facilities & Practices   GISO, §5213(m)
Medical Surveillance  GISO, §5213(n)
General   GISO, §5213(n)(1)
Examinations
Initial Examinations GISO, §5213(n)(2) 
Periodic Examinations   GISO, §5213(n)(3)
Additional Examinations   GISO, §5213(n)(4)
Information Provided to the Physician  GISO, §5213(n)(5)
Physician's Written Opinion   GISO, §5213(n)(6)
Methods of Compliance  GISO, §5213(g)
Engineering & Work Practice Controls  GISO, §5213(g)(1)  
Compliance Program   GISO, §5213(g)(2)
Observation of Monitoring  GISO, §5213(r)
Protective Clothing & Equipment  GISO, §5213(j) 
Respiratory Protection  GISO, §5213(h)
General   GISO, §5213(h)(1)
Respirator program  GISO, §5213(h)(2)
Respirator selection   GISO, §5213(h)(3)
Record keeping   GISO, §5213(q)
Objective Data, Exempted Operations   GISO, §5213(q)(1)
Exposure Monitoring  GISO, §5213(q)(2)
Medical Surveillance  GISO, §5213(q)(3)
Availability of Records  GISO, §5213(q)(4)
Transfer of Records  GISO, §5213(q)(5)
Regulated Areas  GISO, §5213(f) 
Reporting of Use & Emergencies,  per §5203  GISO, §5213(d)
Signs & Labels  GISO, §5213(p)
General   GISO, §5213(p)(1)
Signs   GISO, §5213(p)(2)
Labels  GISO, §5213(p)(3)
ACRYLYL CHLORIDE
Process Safety Management GISO, §5189, Appx A
ACTINOLITE, Non Asbestiform GISO, §5208.1
See Also CARCINOGENS, Regulated
Asbestos Standard GISO, §5208(a)(4)  
Caution Signs  GISO, §5208.1(h) 
Caution Labels  GISO, §5208.1(i)
Change Rooms & Special Clothing  GISO, §5208.1(e)
Employee Information & Training  GISO, §5208.1(n) 
Training Program  GISO, §5208.1(n)(1)
Access to Training Materials  GISO, §5208.1(n)(2)
Employee Notification  GISO, §5208.1(k) 
Engineering Controls  GISO, §5208.1(b) 
Exposure Monitoring GISO, §5208.1(g)
Exposure Limits GISO, §5208.1(a)
Monitoring  GISO, §5208.1(g)(1)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Permissible Exposure Limits GISO, §5208.1(a)
Respiratory Protective Equipment  GISO, §5208.1(d) 
Laundering contaminated clothing  GISO, §5208.1(f)
Monitoring & Record Keeping  GISO, §5208.1(g)
Exposure Limits GISO, §5208.1(a)
Monitoring  GISO, §5208.1(g)(1)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Medical Surveillance  GISO, §5208.1(j) 
Medical Examinations   GISO, §5208.1(j)(1)
Record keeping    GISO, §5208.1(j)(2)
Notification of Employees GISO, §5208.1(k) 
Record Keeping  GISO, §5208.1(g)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Reports of Use Per §5203  GISO, §5208.1(l) 
Respiratory Protective Equipment  GISO, §5208.1(d) 
Personal Protective Equipment
Respiratory Protective Equipment  GISO, §5208.1(d) 
Special Clothing  GISO, §5208.1(e)
Training & Employee Information  GISO, §5208.1(n) 
Training Program  GISO, §5208.1(n)(1)
Access to Training Materials  GISO, §5208.1(n)(2)
Transfer of Records  GISO, §5208.1(m)
Work Practices  GISO, §5208.1(c)
ACTION PLAN, Emergency  GISO, §3220
Application & Scope GISO, §3220(a)
Elements, Essential GISO, §3220(b)
Alarm System GISO, §3220(c)
Evacuation GISO, §3220(d)
Training  GISO, §3220(e)
ACUTELY HAZARDOUS CHEMICALS
List of GISO, §5189, Appx A
Process Safety Management of See PROCESS SAFETY MANAGEMENT
ADAPTERS 
Electrical, 2 to 3 Pole, Prohibition ESO-LV, §2510.58(d)
ADIPIC ACID, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ADIPONITRILE, Airborne Contaminant, Exposure limit GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ADJUSTING, Equipment See LOCK-OUT/TAG-OUT
Prime Movers, Machinery & Equipment GISO, §3314
ADMINISTRATIVE CONTROLS See HAZARD CONTROL 
Noise control  GISO, §5096(b)
When engineering controls not feasible  GISO, §5141(b)
ADVANCE PLANNING OF PROJECTS CSO, §1938, Appx A
ADVERTIZING STRUCTURES / SIGNS, Outdoor  GISO, Article 11
Fall Protection Requirements GISO, §3416
General  GISO, §3412
Ladders  GISO, §3413
Ladder Scaffolds GISO, §3414
Poster Ladder Scaffolds GISO, §3414
Suspended Scaffolds GISO, §3415
AERIAL DEVICES & ELEVATING WORK PLATFORM 
Application  GISO, §3636
Definitions GISO, §3637
Control Devices, Elevating Work Platforms GISO, §3642(d) 
Design / Factors of Safety GISO, §3639
Elevated Work Platform Equipment GISO, §3642
Emergency Stopping Device GISO, §3642(e)
Equipment Requirement, Elevating Work Platforms GISO, §3642
Factors of Safety of Design GISO, §3639
Fall Protection
Aerial Device GISO, §3648(o)
Elevating Work Platforms GISO, §3642(a)
General Requirements GISO, §3638
Guardrail, Elevating Work Platforms GISO, §3642(a)
Guarding of Moving Parts GISO, §3643
High-Voltage Operations, used during ESO-HV, §2940.7(b)
Defined  ESO-HV, §2700
Inspection GISO, §3640
Records of GISO, §3640(d)(1)
Load limits GISO, §3648(f) 
Maintenance GISO, §3640
Operating Instructions, Aerial Devices GISO, §3648
Operating Instructions, Elevating Work Platforms GISO, §3646
Orchard Manlifts (Pruning Towers) GISO, §3641
Platforms, Pin-On GISO, §3647
Pruning Towers (Orchard Manlifts) GISO, §3641
Repair GISO, §3640
Records of GISO, §3640(d)(1)
Safety Belt/ Harness, Aerial Device GISO, §3648(o)
Stability on Inclined Surfaces GISO, §3645
AERIAL DEVICES, Tree Work GISO, §3424(b)
                See also TREE WORK, Maintenance & Removal
High-Voltage Operations ESO-HV, §2940.7(b)
AERIAL Lifts, Fixed Grip See under PASSENGER TRAMWAY SAFETY ORDERS 
AERIAL TRAMWAYS, Detachable Grip See under PASSENGER TRAMWAY SAFETY ORDERS 
AERIAL TRAMWAYS, Subject to MSO MSO, §7035
Communication, Telephone MSO, §7035(a)
Employee transport requirements MSO, §7035(b)
Guarding work areas  MSO, §7035(d)
Standby power supply MSO, §7035(c)
AEROSOL TRANSMISSIBLE DISEASES (ATD) GISO, §5199
Application & Scope GISO, §5199(a)
ATP (Aerosol transmissible pathogen) GISO, §5199(b)
Definitions GISO, §5199(b)
Exposure Control Plan GISO, §5199(d)
Exposure Incidents GISO, §5199(f)(6)
Engineering Controls  GISO, §5199(e)
Laboratories GISO, §5199(f)
Medical Services GISO, §5199(h)
Medical Evaluation Questionnaire GISO, §5199, Appx B
Personal Protective Equipment GISO, §5199(e)
Record keeping GISO, §5199(j)
Work Practice Controls  GISO, §5199(e)
Referring Employers GISO, §5199(c)
Respiratory Protection GISO, §5199(g)
Training GISO, §5199(i)
TB Test GISO, §5199(f)(3)
Tuberculosis, Respiratory Protection from GISO, §5147
Vaccinations, Mandatory & Non-Mandatory Requirements Listed GISO, §5199, Appx E, F
Declination of Vaccinations, Mandatory Forms GISO, §5199, Appx C1, C2
AEROSOL TRANSMISSIBLE DISEASES – ZOONOTIC GISO, §5199.1
Application, Scope & Definitions  GISO, §5199.1(a)
ATP (Aerosol transmissible pathogen) GISO, §5199.1(a)(4)
Disease control procedures 
Work Operations involving ATP infected Animal GISO, §5199.1(d)
Wildlife, Exposure to potentially infectious wildlife GISO, §5199.1(b)
Quarantine order, Operations, due to an ATP infection GISO, §5199.1(c)
Employee Safeguards, at no cost to employee GISO, §5199.1(a)(3)
Medical Services GISO, §5199.1(d)(8)
Exams, Evaluations GISO, §5199.1(d)(8)(A), (B), (C), (E)
Vaccinations GISO, §5199.1(d)(8)(D)
Record keeping  GISO, §5199.1(e)
Respiratory Protection   GISO, §5199.1(d)(4)
Quarantine order, due to an ATP infection, during Operations Involving GISO, §5199.1(c)(2)(C)
Toxic or Asphyxiant Gases, protection  per  GISO,  §5144(g) GISO, §5199.1(c)(2)(C)
Wildlife, Exposures, Use of N95 Respirator or Better GISO, §5199.1(b)(3)
Work Operations involving ATP infected Animal GISO, §5199.1(d)(4)
Written Procedure  GISO, §5199.1(d)(1)(C)(4)
Training GISO, §5199.1(d)(9)
Quarantine order, due to an ATP infection, Disease control procedures  GISO, §5199.1(c)
Vaccinations, Medical Services GISO, §5199.1(d)(8)
Wildlife, Exposure to potentially infectious wildlife   GISO, §5199.1(b)
AGE, EMPLOYEE MINIMUM AGE SSO, §8397.4(d)
AGITATION & HEATING OF LIQUIDS IN TANKS PSO-D&P, §6544
AGRICULTURAL OPERATIONS GISO, Article 13
AGRICULTURAL SAFETY ORDERS (AgSO)
Application GISO, §3436
Definitions GISO, §3437
AgSO Agricultural Irrigation Machines ESO-LV, Article 78
Definitions ESO-LV, §2568.2
Disconnecting Means ESO-LV, §2568.8
Energy from More Than One Source ESO-LV, §2568.16
Grounding ESO-LV, §2568.12 
Irrigation Cable ESO-LV, §2568.4
Lightning Protection ESO-LV, §2568.15
AgSO Agricultural machinery & equipment GISO, §3340
Operation Requirement GISO, §3441
AgSO Agricultural Tractor See Tractor under this Heading
Access to moving parts GISO, §3440(f)
Slow Moving Vehicle Emblem  GISO, §3340(d)(6)
AgSO Accident prevention signs GISO, §3340
AgSO Agricultural machinery & equipment GISO, §3440
Access to moving parts GISO, §3440(f)
Accident prevention signs GISO, §3340
Guarding GISO, §3440(d), (e)
Operating Instructions  GISO, §3441
Safe Work Practices GISO, §3441
Warning Signs / decals GISO, §3440(c)
Warning of rotation  GISO, §3440(f)(2)
AgSO Aircraft 
Crop Dusting & Spraying GISO, §3452
Decontamination of GISO, §3451
AgSO Anhydrous Ammonia connections GISO, §3453(b)
AgSO Applicators, Rigs, Tanks, Vessels GISO, §3453
Cautionary instructions GISO, §3453(c)
Connections GISO, §3453(b)
            UFPV, §507 
Gages UFPV, §508
Tanks mounted on farm machinery UFPV, §506
AgSO Aqua ammonia operations  GISO, §3453
Eye wash requirement Also EYEWASH GISO, §3453(g)
AgSO Beet Trucks GISO, §3444
AgSO Carbamates & Organophosphates
Medical requirements GISO, §3450
AgSO Chemical Solutions of a Hazardous Nature
Applicator Rigs, Tanks, Vessels GISO, §3453
AgSO Choppers, cutters, grinders GISO, §3445  
AgSO Communication in language understood by employee GISO, §3438
AgSO Confined Space Entry See CONFINED SPACE ENTRY
AgSO Conveyors & Elevators GISO, §3446  
AgSO Cotton dust, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AgSO Cotton Gins & Seed Cotton Processing Equipment GISO, Article 74
Balers GISO, §4645
Burr extractors GISO, §4646
Drives, Gin stands GISO, §4641
Drives between Gin stands GISO, §4643 
Elevated platforms GISO, §4642(a)
Gin Stands, Drives GISO, §4641
Gin saw GISO, §4640
Guarding
Elevated Platforms GISO, §4642(a)
Gin saw GISO, §4640
Lint gates, automatic interlock GISO, §4645
Power transmission Enclosure GISO, §4642(b)
Screw conveyors GISO, §4647
Locks & padlocks, keys  GISO, §4640(e)
Main drive GISO, §4641
Power drives, Guarding GISO, §4643
Saws GISO, §4640
Guarding GISO, §4640(a)
Access Door GISO, §4640(d)
Qualified Person GISO, §4640(e), (f)
Stop Rotation GISO, §4640(b)
Supervision requirements GISO, §4640(f)
Tools, Custody of GISO, §4640(e)
Vision Panel GISO, §4640(c)
Access Door, securing of GISO, §4640(d)
Warning Signs GISO, §4640(g)
Screw conveyors GISO, §4647
Seed processing machines   GISO, §4640
      GISO, §4647
Stands GISO, §4641
Guarding provided GISO, §4640(a)
Between stands, guarding GISO, §4643
Supervision requirements  GISO, §4640(f) 
Tools, specialized GISO, §4640(e)
Transmission enclosures GISO, §4642
Warning devices GISO, §4644 
AgSO Crop-dusting aircraft GISO, §3452
AgSO Cutters, Choppers, Grinders GISO, §3445
AgSO Date Palm Operations, Fall Protection for GISO, §3458
Inspection of fall protection equipment GISO, §3458(f)
Job briefing  GISO, §3458(e)
Ladders Attached to Date Palms GISO, §3458.1
Positioning devices GISO, §3458(d)
Saddles  GISO, §3458(c)
AgSO Decontamination, Restricted Material GISO, §3451
Machinery, Aircraft, Applicators GISO, §3451(a)
Manufacturers Recommendations GISO, §3451(b)
Neutralizing, Washing GISO, §3451(b)
AgSO Definitions GISO, §3437 
AgSO Drinking water, potable GISO, §3457(c)(1)
AgSO Driveline Guarding, PTO GISO, §3440(c)
Warning of rotation  GISO, §3440(f)(2)
AgSO Electrical Hazards, Overhead GISO, §3455 
AgSO Elevators, Conveyors, guarding GISO, §3446
AgSO Employees, Agricultural Laborers See Laborer under this Heading
AgSO Equipment GISO, §3440
AgSO Explosives & Pyrotechnics
Application & Scope GISO, §5236
Definition of GISO, §5237
Manufacturing & Processing GISO, §5319
AgSO Fall Protection, Date Palm Operations GISO, §3458
Inspection of fall protection equipment GISO, §3458(f)
Job briefing  GISO, §3458(e)
Ladders Attached to Date Palms GISO, §3458.1
Positioning devices GISO, §3458(d)
Saddles  GISO, §3458(c)
AgSO Fertilizers, Restricted Materials 
Applicator Rigs, Tanks, Vessels GISO, §3453
Decontamination of Equipment GISO, §3451
Formulation & Application GISO, §3450
AgSO Field Sanitation GISO, §3457  
Maintenance   GISO, §3457(c)(3)
Potable / Drinking Water  GISO, §3457(c)(1)
Reasonable use GISO, §3457(c)(1)
Reports GISO, §3457(c)(1)
Toilet facilities GISO, §3457(c)(2)
Washing Facilities GISO, §3457(c)(2)
AgSO First-Aid Requirements
At remote locations,  GISO, §3439(b)
Effective Provisions for Care GISO, §3400(f)
Availability of Medical Personnel GISO, §3400(a)
Blankets GISO, §3400(e)
Body wash/drenching GISO, §3400(d)
Eye wash / flush GISO, §3400(d)
  See also under EYEWASH
Aqua Ammonia Operations GISO, §3454(g)
Inspections of 1st Aid supplies GISO, §3400(c)
Medical Requirements, Restricted Materials GISO, §3439
Medical Services, Facilities GISO, §3439(b)
Stretchers GISO, §3400(e)
Supplies GISO, §3400(c)
Telephone communication GISO, §3400(f)
GISO, §§3439(b)
Training  GISO, §3439(b)
GISO, §3400(b)
Transportation GISO, §3400(f)
AgSO First-Aid Kit
Availability of  GISO, §3439(a)
Condition of GISO, §3439(a)
Inspection of  GISO, §3439(a)
Prompt Medical Attention GISO, §3439(b)
AgSO Fruit Picking, Electrically Conductive Poles GISO, §3455(b) 
AgSO Fumigation See FUMIGATION
AgSO Guarding GISO, §3440(d), (e)
Operating Instructions  GISO, §3441
Safe Work Practices GISO, §3441
Warning Signs / decals GISO, §3440(c)
Warning of rotation  GISO, §3440(f)(2)
AgSO Hand-Held Tools GISO, §3456
Short handled, prohibited GISO, §3456(b)
AgSO Hand weeding, thinning GISO, §3456(c)
AgSO Heat Illness Prevention GISO, §3395
Access to Drinking Water GISO, §3395(c)
Maintenance of GISO, §3457(c)(3)
Access to Shade GISO, §3395(d)
>85°,  Shade Requirements GISO, §3395(d)(1)
≤85°,  Shade Requirements GISO, §3395(d)(2)
Agricultural Industry, Subject to Standard GISO, §3395(a)(2)(A)
Application & Scope GISO, §3395(a)(2)
Cool-down Rest Period, Permitted at all Times GISO, §3395(d)(3)
Definitions GISO, §3395(b)
Drinking Water, Access to GISO, §3395(c)
Maintenance of GISO, §3457(c)(3)
High-Heat Procedure GISO, §3395(e)
Oil & Gas Extraction Industry, Subject to Standard GISO, §3395(a)(2)(D)
Rest Period, Cool-down, Permitted at all Times GISO, §3395(d)(3)
Temperature Triggers
>85°,  Shade Requirements GISO, §3395(d)(1)
≤85°,  Shade Requirements GISO, §3395(d)(2)
95°,  High-Heat Procedure GISO, §3395(e)
Training GISO, §3395(f)
Transportation of Agri-Products, Construction & other Heavy Materials GISO, §3395(a)(2)(E)
Exception, Operators in Air-conditioned Vehicles GISO, §3395(a)(2)(E)
AgSO Horizontal Rotary Spreaders GISO, §3442
AgSO Insecticides, Restricted Materials 
Formulation & Application GISO, §3450
Decontamination of Equipment GISO, §3451
Applicator Rigs, Tanks, Vessels GISO, §3453
AgSO Ladders Attached to Date Palms GISO, §3458.1
AgSO Lock-out / Block-out GISO, §3441(a)(2)(C)-(E) 
AgSO Medical Requirements, Restricted Materials GISO, §3439
AgSO Non-English-speaking workers, communication with GISO, §3438
AgSO Organophosphates & Carbamates
Medical requirements GISO, §3450
AgSO Overhead Electrical Hazards GISO, §3455
AgSO Pesticides, Restricted Materials 
Applicator Rigs, Tanks, Vessels GISO, §3453
Decontamination of Equipment GISO, §3451
Formulation & Application GISO, §3450
Medical Requirements GISO, §3439
AgSO Potable water GISO, §3457
AgSO Pyrotechnics & Explosives
Application & Scope GISO, §5236
Definition of GISO, §5237
Manufacturing & Processing GISO, §5319
AgSO Restricted Materials 
Applicator Rigs, Tanks, Vessels GISO, §3453
Decontamination of Equipment GISO, §3451
Formulation & Application GISO, §3450
Medical Requirements GISO, §3439
AgSO Rollover Protective Structures (ROPS)    GISO, §3651
AgSO Seatbelts  GISO, §3653
AgSO Sheep shearing operations GISO, §3454
AgSO Short-handled hoe  GISO, §3456(a)
AgSO Signs, Accident Prevention GISO, §3340
Slow Moving Vehicle Emblem  GISO, §3340(d)(6)
AgSO Spillage, Accidental, Aqua Ammonia, Eye Wash Requirement See also EYEWASH GISO, §3453(g)
AgSO Tanks GISO, §3453 
Applicator GISO, §3453(a), (c), (e) 
Applicator GISO, §3453(f), (g), (h)
Decontamination GISO, §3451
Liquid Level Indicator GISO, §3453(a)
Marking, content  GISO, §3453(c)
Pressure Vessels GISO, §3453(h)
AgSO Toilet Facilities See Field Sanitation under this Heading
AgSO Tools, Hand-Held GISO, §3456
AgSO Tractors 
Accident prevention signs GISO, §3340
Brakes
Brake & Parking Brake Requirement GISO, §3661
Locking / Parking GISO, §3440(b)
Definitions  GISO, §3649
Deflector Guards  GISO, §3654
Fenders GISO, §3440(a)
General Requirements GISO, §3651
Guards, Wheel, Fenders GISO, §3440
Deflector GISO, §3654
Headlights GISO, §3441
Inspection / Operational Check, Daily GISO, §3664(c)
Internal Combustion Engines, Use of  GISO, §3662
Operating instructions for employees GISO, §3664(b) 
Operator Platforms GISO, §3658
Power-Take-Off (PTO) GISO, §3440(c)
Rated Capacity  GISO, §3660
Rollover Protective Structures (ROPS)    GISO, §3651
Seatbelts  GISO, §3653
Shear or Brush Guarding GISO, §3654(a)(1)
Training GISO, §3664(b)
Warning Devices, Audible GISO, §3661
Wheel Guards  GISO, §3665
AgSO Transportation of Employees & Materials GISO, Article 27  
Farm Labor Vehicle      GISO, §3700
Licensing of Drivers GISO, §3701(a)
Seatbelts Required GISO, §3702(h)
Rollover Protective Structures (ROPS)    GISO, §3651
Shear or Brush Guarding GISO, §3654(a)(1)
Vehicle Requirements   GISO, §3702
Licensing of Drivers GISO, §3701(b)
AgSO Vegetable Trimming Saws GISO, §3447  
AgSO Vehicles See FARM LABOR VEHICLES
Accident prevention signs GISO, §3340
AgSO Vessels (Containers) See also Tanks under this Heading 
Applicator Rigs, Tanks GISO, §3453
Pressure GISO, §3453(h)
Washing facilities, field sanitation GISO, §3457
AgSO Water Hazards GISO, §3448
AGRICULTURAL VEHICLE, SIGN, Slow Moving Vehicle GISO, §3340(d)(6)
AIDS, HIV See BLOODBORNE PATHOGENS
AIR, Compressed, Equipment
Construction of Cylinders GISO, §4649
Handling of Cylinders GISO, §4650
Leaking Cylinders GISO, §4650(p)
Marking of Cylinders GISO, §4649
Pneumatic Nailers & Staplers, per CSO CSO, §1704 
Definitions CSO, §1704(a)
General Safety Requirements CSO, §1704(b)
Disconnecting Requirement CSO, §1704(c)
Air Hose, Securing of CSO, §1704(d)
Safety Device CSO, §1704(e)
Code of Safe Practice Requirement CSO, §1704(f)
Trainers  CSO, §1704(g)
Pneumatic Tools, per GISO    GISO, §3559
Prohibited Use of LP Gas in UFPV, §474(b)
Safety Relief Devices GISO, §4657
Storage of Cylinders GISO, §4650
Use of Cylinders GISO, §4650
AIR, Compressed, Use of GISO, §3301
AIR COMPRESSORS GISO, §3518
  See also AIR TANKS, Compressed Air
  See also UNFIRED PRESSURE VESSELS
Automatic Start Warning  GISO, §3320
Bleeding before Repairs, per MSO  MSO, §6996(b) 
Centrifugal (radial) compressor systems  GISO, §3518
Diving Operations GISO, §6057(a), (d)
Grounding, Electrical  ESO-LV, §2395.45(A)
Permit Required for Tanks  UFPV, §450(a)(3)
Posting of Permit UFPV §461©
Exempted Tanks UFPV§ 461(f)
Prohibited uses of GISO, §3301(b), (e)
In Flammable gasses/vapors GISO, §3518(b)
In Toxic atmospheres GISO, §3518(b)
Portable Air Compressors CSO, §1696
Blocking / Locking of Air Compressors  CSO, §1696(a)
Grounding, Electrical  ESO-LV, §2395.45(A)
Guarding Fans of Air Compressors  CSO, §1696(b)
Draining of Condensate in Air Compressors  CSO, §1696(c)
Testing, Safety Valves  CSO, §1696(d)
Tanks, Comply UVPV  CSO, §1696(e)
Radial Air Compressor systems  GISO, §3518
Stationary Internal Engines Driving Compressors  PSO-D&P, §6554
Bleeding before Repairs, per MSO MSO, §6996(b) 
AIR CONDITIONING, Cooler Doors, Food Service GISO, §4536
AIR CONDITIONING, HVAC, Building Ventilation GISO, §5142
Grounding or, Cord & Plug Connected  ESO-LV, §2395.45(A)
Indoor Air Quality, HVAC Systems GISO, §5142
System Requirements GISO, §5143
AIR FILTERS See HEPA FILTERS
Testing Protocol  GISO, §5155, Appx A
AIR / GAS CYLINDERS
Connections of Cylinders, Approved GISO, §4649(b)
Construction of Cylinders GISO, §4649(a)
Crane, Hoist & Derrick, Hoisting of Cylinders GISO, §4650(i)
Dropping of Cylinders Prohibited GISO, §4650(n)
Handling of Cylinders GISO, §4650
Dropping of Cylinders Prohibited GISO, §4650(n)
Rolling & Carrying of Cylinders GISO, §4650(h), Exception
Striking of Cylinders Prohibited GISO, §4650(n)
Prying of Cylinders from Frozen Ground GISO, §4650(n)
Hoisting Cylinders GISO, §4650(i)
Leaking Cylinders, Regulators, Valves, Hose, Piping GISO, §4650(p)
Marking / Labeling of Cylinders GISO, §4649(d)
Portable Service, Cylinder Used in GISO, §4650(h)
Secured in Suitable Trucks GISO, §4650(h)
Rolling & Carrying of Cylinders GISO, §4650(h), Exception
Safety Relief Devices GISO, §4657
Securing of Cylinders when in Use
In Racks / Structures  GISO, §4650(h)
In Portable Service, in Suitable Trucks GISO, §4650(h)
Storage of Cylinders GISO, §4650
Barriers, Oxygen & Fuel Cylinders GISO, §4650(d)
Combustible Materials, Away from GISO, §4650(b)
Valve Protection Required GISO, §4649(f)
Dry, Protected from Moisture GISO, §4650(b)
Heat, Protected from GISO, §4650(a)
Oil & Accelerators, Away from GISO, §4650(b)
Oxygen & Fuel Cylinders Separated GISO, §4650(d)
Securing, Protection from Falling / Tipping GISO, §4650(e)
Unventilated Enclosures, Prohibition GISO, §4650(c)
Ventilation Requirement GISO, §4650(b)
Heat, Protected from GISO, §4650(a)
Transporting of Cylinders GISO, §4650(e)
Valve Protection Required GISO, §4650(g)
See Exception GISO, §4650(g)
Lifting, Not Used for GISO, §4650(j)
Crane, Hoist & Derrick, Hoisting of Cylinders GISO, §4650(i)
Use of Cylinders GISO, §4650
Used As Support or Rollers Prohibited GISO, §4650(q)
Electrical Circuit, Part of GISO, §4650(r)
Use Content only as Intended by Supplier GISO, §4650(s)
Acetylene, Contact with Unalloyed Copper  GISO, §4650(t)
Purging of lines, Parts, Equipment   GISO, §4650(u)
Valves
Closed Before Moving GISO, §4650(k)
Closed When Work is Finished GISO, §4650(m)
Closed on all Empty Cylinders GISO, §4650(k)
Keys, Handles, on Valve Stems, Spindle GISO, §4650(o)
Repair / Tampering with Valves GISO, §4650(p), Notes
Valve Protection / Collar or Recess GISO, §4649(c)
Leaking Valves, Use Prohibited GISO, §4650(p)
Requirement when Cylinders not in Use or Connected GISO, §4650(f)
Requirement before moving Cylinders GISO, §4650(g), (h)
See Exception GISO, §4650(g)
Not Used for Lifting GISO, §4650(j)
AIR / GAS, Use of GISO, §3301
AIR HOSES, per CSO
Securing hoses on elevated locations CSO, §1700
AIR HOSES, per GISO 
Securing Hose, used to Agitate Liquids in Tanks / Vats GISO, §3300(a)
Maintenance, Hose Connections GISO, §3300(b)
Used, for which Designed / Constructed GISO, §3300(c)
AIR HOSES, per MSO  MSO, §6997
AIR INTAKE SHUT OFF VALVE, per PSO-D&P PSO-D&P, §6625.1
AIR NOZZLES SAFETY GISO, §3301 
AIR POLLUTION CONTROL
Asbestos  See ASBESTOS  
Dust control  See DUST
Mining operations See AIR QUALITY, RADIATION & VENTILATION, Per MSO
Tunneling Operations TSO, §8437
Ventilation  See VENTILATION  
AIR QUALITY 
Breathing Air Quality, Supplied Air Respirator & SCBA GISO, §5144(i) 
Compressed Air, Diving Operations GISO, §6057(b)(3)
HVAC Systems GISO, §5142
Pressurized Worksite Operations, per GISO, §5144(i)  GISO, §6100(e)
Respirator, Supplied Air & SCBA GISO, §5144(i) 
AIR QUALITY & VENTILATION, per TSO TSO, §8437 
AIR QUALITY, RADIATION & VENTILATION, Per MSO MSO, Article 31 
Environmental Controls MSO, §7090
Blasting  MSO, §7095
Dust Control
Blasting, Primary MSO, §7095
Blasting, Secondary MSO, §7096
Surface Drilling MSO, §7092
Underground Rock Drilling MSO, §7093
Mucking & Transferring Rock MSO, §7094 
Smoke & Gas Control
Blasting, Primary MSO, §7095
Blasting, Secondary MSO, §7096
Radiation, Underground MSO, §7091
Surface operations MSO, §7092
Underground operations MSO, §7093
Ventilation MSO, §7098
Mechanical Ventilation MSO, §7099
AIR TANKS UFPV, Article 3
Alteration, authorization by inspector  UFPV, §466
Applicable UFPV, §450(a)(3)
Certification of Inspectors  UFPV, §463 
Change of ownership, effect on permit UFPV, §461
Compressor, installation,  UFPV, §462
Construction UFPV, §454
Definitions UFPV, §453
Design  UFPV, §454
Drain  UFPV, §465
Drive unit, installation  UFPV, §462
Exempted Tanks UFPV, §451
Field Inspections & Reports  UFPV, §462
Gage  UFPV, §465
Haulage vehicles CSO, §1591
Headings, requirements  UFPV, §462
Identification, state serial number UFPV, §462(g)
Inspection    UFPV, §461
Fees See Cal/OSH, §344.1
Reports UFPV, §462
Inspectors 
Alterations & repairs, authorization by UFPV, §466
Certification of  UFPV, §463
Installation UFPV, §462
Accessibility for inspection UFPV, §462
Labels  UFPV, §462
Manufacturer’s data report UFPV, §462
Permit to Operate UFPV, §450(a)(4)
Posting of Permit UFPV, §461(c)
Exempted Tanks UFPV, §461(f)
Piping UFPV, §462
Discharge pipes, safety valves & rupture discs  UFPV, §465
Plastic Piping   UFPV, §462
Pressure-indicating gage UFPV, §465
Rejection mark, unfit for service UFPV, §462
Repair, authorization by inspector UFPV, §466
Repairs & Alterations  UFPV, §466
Reports
Inspections UFPV, §462
Manufacturer’s data report UFPV, §462
Welding repairs or alterations UFPV, §466
Safety Valves & Devices  UFPV, §465
State serial number UFPV, §462
Unfit for service UFPV, §462
Welding repairs UFPV, §466
AIRBORNE CONTAMINANTS, per GISO GISO, §5155
Application / Scope GISO, §5155(a)
Definitions GISO, §5155(b)
Asphyxiants GISO, §5155, Table AC-1(h)
Ceiling Limits GISO, §5155(c)(3)
Contaminants, Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Cotton Waste Processing Operations GISO, §5155, Table AC-1(j)
Dust 
Exposure limit GISO, §5155(c)
Medical Surveillance Program GISO, §5155(f)
Permissible Exposure limit (PEL) GISO, §5155, Table AC-1
Protective Clothing for Chemicals w/ S Notation GISO, §5155(d)
Workplace Monitoring GISO, §5155(e)
Exposure Computations GISO, §5155, Appx A
Exposure Limits GISO, §5155(c)
Permissible Exposure Limits GISO, §5155(c)(1)
Short Term Limits GISO, §5155(c)(2)
Listed, Permissible Exposure Limits of Contaminants GISO, §5155, Table AC-1
Monitoring, Workplace GISO, §5155(e)
Medical Surveillance GISO, §5155(f)
Permissible Exposure Limits GISO, §5155, Appx A, Table AC-1 & Foot Notes
For Chemical Contaminants, Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Skin Absorption, Protection Against GISO, §5155(d)
AIRBORNE CONTAMINANTS, per TSO See under TUNNELING OPERATION, Air Quality
AIRCRAFT
Avalanche Blasting Activities from Helicopters GISO, §5357(d)
Explosives, transporting of using Aircraft GISO, §5269
Hangars, Hazardous Locations (Classified) ESO-LV, §2540.6
Hazardous Location, Hanger ESO-LV, §2540.6
Helicopter Operations, Construction  CSO, Article 35
Application / Scope CSO, §1900
Cargo Loading & Handling CSO, §1908
Communications        CSO, §1906
Exposed Locations CSO, §1909 
Fall Exposure  CSO, §1909 
Fueling      CSO, §1905
General Requirements      CSO, §1901
Ground Crew CSO, §1907
Landing Operations      CSO, §1903
Static Electricity      CSO, §1904
Helicopter Operations, Logging LSSO, Article 11 
Communication & Signal System LSSO, §6326
Fueling & Fueling Area LSSO, §6325
Bonding Requirement while fueling LSSO, §6325(e)
General Requirements LSSO, §6320 
Ground Personnel LSSO, §6324
Signals, Hand, Illustration LSSO, §6402, Appx A
Hooking & Unhooking Loads LSSO, §6322
Landings LSSO, §6323
Personal Protective Equipment LSSO, §6327
Rigging LSSO, §6321
Safe Practices LSSO, §6402, Appx A
Helicopter Operations, Tunneling, Emergency Medical Service TSO, §8420(b) 
Loading , Conveyors, or Belt Loaders, Fall Protection GISO, §3210(b), Exception (7)
Wheel Well, Work in or on, Fall Protection GISO, §3210(b), Exception (8)
AIRLESS SPRAY GUNS GISO, §3559.1 
Safety Device, Trigger Lock GISO, §3559.1(a) 
Diffuser Nut GISO, §3559.1(b) 
Nozzle Tip Guard GISO, §3559.1(b) 
AIR-LIFT HAMMER GISO, §4240
AISLES, per GISO
Aisles, Walkways & Crawlways  GISO, §3272
Blocked  GISO, §3225(a)
Clearance GISO, §3272(c) & (e)
Forklifts Access GISO, §3272(b)
Lighting of GISO, §3317
Marked  GISO, §3272(c)
Traffic GISO, §3272(e) & (f)
Width GISO, §3272(b)
AISLE, per TelSO TelSO, §8602(c)
ALARM SYSTEMS See also SIGNALS
Backup   CSO, §1592
   GISO, §3706(b)
Fire Protection GISO, §6184
See also FIRE PROTECTION
Application & Scope GISO, §6184(a)
Design Requirements GISO, §6184(b)
Installation & Restoration GISO, §6184(c)
Maintenance GISO, §6184(d)
Manual Operation GISO, §6184(e)
Testing GISO, §6184(d)
ALCOHOL See FLAMMABLE LIQUIDS, GASES & VAPORS
Prohibition of ignition sources near anywhere GISO, §5416(c)
Pits & Sumps GISO, §5416(b)
Smoking prohibition  GISO, §5416(d)
Ventilation  GISO, §5416(a)
ALCOHOLIC BEVERAGES, Consumption of
Areas & Locations for Consumption GISO, §3368(a) & (d)
Prohibited Areas & Locations GISO, §3368(b)
  Waste Disposal Containers GISO, §3368(c)
Mining Operations, Alcohol & Drugs Prohibition MSO, §6973(c)
Blasting or Pyrotechnic Operations, Alcohol & Drugs Prohibition GISO, §5247(b)
ALDRIN, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALKYLALUMINUMS
Process Safety Management GISO, §5189, Appx A
ALLAYING DUST, FUMES, MISTS, VAPOR & GASES PSO-R,T&H, §6788
ALLIGATOR SHEARS, Metal Work  (Class B) See under METAL WORKING MACHINES
ALLYL ALCOHOL, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALLYLAMINE
Process Safety Management GISO, §5189, Appx A
ALLYL CHLORIDE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Process Safety Management GISO, §5189, Appx A
ALLYL GLYCIDYL ETHER, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALLYL PROPYL DISULFIDE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALTERATIONS & REPAIR, Pressure Vessels & Boilers PSO-D&P, §6551(d)
ALTERNATING-CURRENT, Circuits and Systems
Equipment Grounding for ESO-LV, §2395.5
Common grounding electrode ESO-LV, §2395.54
Conductor ESO-LV, §2395.25
Connections ESO-LV, §2395.23
ALUMINUM, ALKYLS, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM, Combustible Metal GISO, §5175
ALUMINUM DISTEARATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM METAL & OXIDE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM PYRO POWDERS, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Combustible Metal GISO, §5175
ALUMINUM SOLUBLE SALTS, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A   
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM STEARATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM TRISTEARATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ALUMINUM WELDING FUMES, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMINODIPHENYL, 4-Aminodiphenyl    See CARCINOGENS, Specified
AMINOPYRIDINE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMITROLE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMONIA, ANHYDROUS    See ANHYDROUS AMMONIA
AMMONIA SYSTEMS, Pressure Vessels See ANHYDROUS AMMONIA SYSTEMS
AMMONIUM CHLORIDE FUMES, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMONIUM NITRATE, Explosives See under EXPLOSIVES
AMMONIUM PERCHLORATE 
Process safety management GISO, §5189, Appx A
AMMONIUM PERFLUOROCTANOATE, Airborne Cont., Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMONIUM PERMANGANATE
Process Safety Management GISO, §5189, Appx A
AMMONIUM STEARATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMONIUM SULFAMATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AMMUNITION & PROPELLANTS, Small Arms GISO, Article 123
Application & Scope GISO, §5370
Ammunition Primers, Small Arms  GISO, §5374
Ammunition, Small Arms GISO, §5371
Black Powder Propellants GISO, §5373
Primers, Small Arms  GISO, §5374
Propellants, Smokeless   GISO, §5372
Storage  GISO, §5371(b)
Separated from Flammable Materials & Oxidizers GISO, §5371(a)
AMOSITE, Asbestiform See ASBESTOS
AMPACITY
Circuits, Branch & Feeder Circuits ESO-HV, §2734
Conductors ESO-HV, §2716
Per IPCEA Publication No. P46-426  ESO-HV, §2821
Definition ESO-HV, §2700
AMUSEMENT RIDE SAFETY ORDERS, Permanent  PARSO, Subchapter 6.2
Application & Definitions  PARSO, Article 1
Applications  PARSO, §3195.1
Definitions PARSO, §3195.2
AMUSEMENT RIDES, Permanent
                             See also AMUSEMENT RIDES, Portable & Permanent Rides, per GISO
Access & Exiting rides PARSO, §3195.9(g)
Aquatic devices PARSO, Article 3
Application PARSO, §3195.10
Operation & Maintenance  PARSO, §3195.11
ASTM standards incorporated by reference PARSO, §3195.1
Brakes PARSO, §3195.9(a)
Confidentiality Of Documentation & Records PARSO, §3195.14
Control & Operation of Rides PARSO, §3195.9(h)
Definitions PARSO, §3195.2
Design PARSO, §3195.4
Documentation required PARSO, §3195.3
Electrical Wiring Affecting Permanent Rides PARSO, §3195.9(i)
Emergency Brakes & Devices PARSO, §3195.9(a)
Emergency Medical, First Aid, CPR PARSO, §3195.7(c)
Exiting & Access to rides Requirements PARSO, §3195.9(g)
Governors, Mechanical PARSO, §3195.9(c)
Hazard control measures PARSO, §3195.9
Identification of Amusement Rides PARSO, §3195.8(b)
Inspections & Related Training  PARSO, §3195.6
Maintenance, Inspection & Related Training PARSO, §3195.6
Instructions, Manufacturer Originated PARSO, §3195.3(a)
Testing PARSO, §3195.5
Manufacturer Originated Documentation PARSO, §3195.3(a)
Manufacturing Requirements PARSO, §3195.4
Motion restriction  PARSO, §3195.9
Operation & Control of Rides PARSO, §3195.9(h)
Operation Procedures & Related Training PARSO, §3195.7
Operation within Design & Use Specifications PARSO, §3195.8(a)
Patron / Rider Protection PARSO, §3195.9(a)
Portable Rides See AMUSEMENT RIDES, Including Portable Rides, per GISO
Record keeping & Information Transfer PARSO, Article 4
Confidentiality of Documents PARSO, §3195.14 
Record keeping Requirements PARSO, §3195.12
Transfer of Information with Sale of Used Rides PARSO, §3195.13
Registration Number of amusement rides PARSO, §3195.8(b)
Rider Protection PARSO, §3195.9(a)
Restraints, support PARSO, §3195.9(f)
Signaling Devices PARSO, §3195.9(d)
Speed Limiting Devices & Systems PARSO, §3195.9(c)
Testing Requirement PARSO, §3195.5
Operational Testing, Manufacturer Originated PARSO, §3195.3(a)
Training
Maintenance & Inspection Personnel  PARSO, §3195.6
Patrons, Riders PARSO, §3195.7(b)
Ride Operators/ Attendants PARSO, §3195.7(a)
First Aid, CPR PARSO, §3195.7(c)
Used, Transfer of Information PARSO, §3195.13
AMUSEMENT RIDES, Portable & Permanent Rides, per GISO GISO, Article 35
                             See also AMUSEMENT RIDES, Permanent
Application / Purpose.  GISO, §3900
Definitions GISO, §3901
Accident
Notification, Cal/OSHA GISO, §3920
Permits, Effect on GISO, §3915(b)
Analysis, Manufacturer’s  GISO, §3902
Anti-Rollback Devices & Emergency Brakes GISO, §3904
For permanent rides, per PARSO PARSO, §3195
Assembly & Disassembly of Rides GISO, §3911
Authorized Person, Operator GISO, §3912
Brakes, Emergency GISO, §3904
For permanent rides, per PARSO PARSO, §3195.9
Bungee Jumping Operation, Defined as Amusement Ride GISO, §3901(a)
Certification GISO, §3914
Construction of Supporting Devices GISO, §3909
Controls GISO, §3912
For permanent rides GISO, §3195.9
Daily Maintenance Requirements GISO, §3910
Definitions GISO, §3901
For permanent rides, per PARSO PARSO, §3195.2
Design of Supporting Devices GISO, §3909
Disassembly of Rides GISO, §3911
Disconnect Switch, Control of Operation GISO, §3912
Dodge-Em type rides GISO, §3907(b)
Electrical Equipment Requirements, per PARSO PARSO, §3195.9
Emergency brakes & anti-rollback devices  GISO, §3904
Controls Within Reach of Operator GISO, §3912
For permanent rides, per PARSO PARSO, §3195.9
Endangering the public prohibited GISO, §3913
Fences, barricading, guarding the public  GISO, §3913
Identification & Rating Plate of each Ride GISO, §3918
Inspections, required GISO, §3914
Inspection Fees GISO, §3916
Maintenance, Daily GISO, §3910
Manufacturer’s analysis   GISO, §3902
Modified & Rebuilt Rides GISO, §3919
Notice, rebuilt or modified devices GISO, §3919(a)
Stress Analysis GISO, §3919(a)
Revised Certificate of Inspection GISO, §3919(b)
Operator, Authorized Person GISO, §3912
Passenger Carrying Rides GISO, §3907(a) 
Passenger-Operated Rides GISO, §3907(b)
Passenger Restraining / Containing Safety Devices GISO, §3908
Provided & Maintained GISO, §3907(c)
Permanent Amusement Ride Safety Orders (PARSO)  Subchapter 6.2
Applicability PARSO, §3195.1
Definitions PARSO, §3195.2
Permanent Amusement Rides See AMUSEMENT RIDES, Permanent 
Permits
Issuance GISO, §3915
Posting of GISO, §3917
Rating Plate of each Ride GISO, §3918
Rebuilt and Modified  GISO, §3919
Safety Devices, Passenger GISO, §3908
Seatbelts &  Restraints GISO, §3907(c)
Design, Construction & Maintenance of GISO, §3908
Speed Limiting Devices GISO, §3905
Signal Systems  GISO, §3906
Testing, Required By Cal/OSHA GISO, §3903
Public Protection GISO, §3913
Inspections, Registered GISO, §3914
Inspection Fee  GISO, §3916
Inspection Fee Schedule GISO, §3920, Appx 1
Permit, Issuing of GISO, §3915
Permit, Posting of GISO, §3917
Rebuilt & Modified Rides GISO, §3919
Registration number GISO, §3918
Safety belts GISO, §3907
Signal systems GISO, §3906
For permanent rides, per PARSO PARSO, §3195.9
Smooth, Free From Sharp, Rough, Splintered Edges GISO, §3907(a)
Speed limiting devices GISO, §3905
For permanent rides, per PARSO PARSO, §3195.9(c)
Stress analysis to be furnished GISO, §3902
Supporting structures, design & construction GISO, §3909
Testing GISO, §3903
Tools for assembly & disassembly GISO, §3911
AMYL ACETATE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ANCHORING, Fixed Machinery  GISO, §3328(d) 
ANCHORS & FITTINGS, Window Cleaning Equipment GISO, §3283
ANGLE OF RISE
Fixed Industrial Stairs GISO, §3234(e)
Illustrations GISO, §3231
Fixed Ladders GISO, §3277(h)
Illustrations GISO, §3277
Ladder, Illustration GISO, §3231, Figure E-1
Construction Usage, Illustration CSO, §1938, Appx B, Plates B-16 & B-17
Stairwells, per CSO CSO, §1626(b)(2)
Illustration CSO, §1938, Appx B, Plates B-17
ANHYDROUS AMMONIA 
Agricultural operations
Applicators  GISO, §3453
Cautionary instructions GISO, §3453(c)
Connections GISO, §3453(b); 
Gages UFPV, §508
Tanks mounted on farm machinery UFPV, §506
Tanks mounted on farm machinery UFPV, §506
Compressors
Refrigerated storage containers UFPV, §514
Transfer operation use UFPV, §509(f)
Cylinders, portable UFPV, §515
Device approval UFPV, §500
DOT cylinders, Portable UFPV, §515
Electrical Equipment Requirements UFPV, §501(c)
Hoses specifications UFPV, §510
Motor vehicles transporting UFPV, §504
Portable cylinders UFPV, §515
Process Safety Management GISO, §5189, Appx A
Pumps for transfer operations UFPV, §509
Refrigerated storage containers, installation of UFPV, §514
Refrigeration systems, use of UFPV, §513
Systems using portable DOT cylinders UFPV, §515
Tanks
Aboveground storage tanks UFPV, §501
Alterations to UFPV, §512
Construction of UFPV, §458
Definitions  UFPV, §453
Design UFPV, §458
Electrical equipment & wiring 
Aboveground storage tanks UFPV, §501
Excess-to flow salves
Aboveground storage tanks UFPV, §501
Motor vehicles, installed on UFPV, §504
Farm machinery, mounted on UFPV, §506
Gages UFPV, §508
Fires, inspection before return to service UFPV, §512
Fittings
Liquid & vapor lines UFPV, §507
Motor vehicles, installed on UFPV, §504
Portable tanks UFPV, §503
Gaging devices UFPV, §508
Hoses, specifications UFPV, §510
Liquid lines UFPV, §507
Mobile storage tanks UFPV, §505
Motor vehicles, installation on UFPV, §504
Gages UFPV, §508
Mobile storage tanks UFPV, §505
Piping
Liquid & vapor lines UFPV, §507
Motor vehicles, installed on UFPV, §504
Portable tanks UFPV, §503
Refrigerated storage containers UFPV, §514
Repairs to UFPV, §512
Safety equipment for workers
Aboveground storage tanks UFPV, §501
Motor vehicles, installed on UFPV, §504
Safety relief valves UFPV, §511
Refrigerated storage containers UFPV, §514
Shutoff valves UFPV, §511
Refrigerated storage containers UFPV, §514
Skid tanks UFPV, §501
Transfer operations UFPV, §509
Valves
Liquid & vapor lines UFPV, §507
Refrigerated storage containers UFPV, §514
Vapor lines UFPV, §507
Warning signs UFPV, §502
Welding UFPV, §512
Transfer operations UFPV, §509
ANHYDROUS AMMONIA SYSTEMS UFPV, Article 6
Approval of Devices UFPV, §500
Electrical Equipment Requirements UFPV, §501(c)
Gauging Devices UFPV, §508
Hose Specification UFPV, §510
Installation of Aboveground Storage Tanks UFPV, §501
Piping, Valves, & Fittings UFPV, §507
Portable DOT Containers, Use of  UFPV, §515
Portable Tanks UFPV, §503
Refrigerated Storage Containers UFPV, §514
Refrigeration Systems  UFPV, §513
Repairs & Alterations UFPV, §512
Safety Relief Valves UFPV, §511
Tanks, Installation on:
Farm Machinery UFPV, §506
Mobile Storage UFPV, §505
Transfer of Liquids UFPV, §509
Vehicle Mounted Tanks UFPV, §504
Warning Signs UFPV, §502
ANILINE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ANIMALS, infected with Zoonotic Aerosol Transmissible Diseases  GISO, §5199.1
Application, Scope & Definitions  GISO, §5199.1(a)
ATP (Aerosol transmissible pathogen) GISO, §5199.1(a)(4)
Disease control procedures 
Work Operations involving ATP infected Animal GISO, §5199.1(d)
Wildlife, Exposure to potentially infectious wildlife GISO, §5199.1(b)
Quarantine order, Operations, due to an ATP infection GISO, §5199.1(c)
Employee Safeguards, at no cost to employee GISO, §5199.1(a)(3)
Medical Services GISO, §5199.1(d)(8)
Exams, Evaluations GISO, §5199.1(d)(8)(A), (B), (C), (E)
Vaccinations GISO, §5199.1(d)(8)(D)
Record keeping  GISO, §5199.1(e)
Respiratory Protection   GISO, §5199.1(d)(4)
Quarantine order, due to an ATP infection, during Operations Involving GISO, §5199.1(c)(2)(C)
Toxic or Asphyxiant Gases, protection  per  GISO,  §5144(g) GISO, §5199.1(c)(2)(C)
Wildlife, Exposures, Use of N95 Respirator or Better GISO, §5199.1(b)(3)
Work Operations involving ATP infected Animal GISO, §5199.1(d)(4)
Written Procedure  GISO, §5199.1(d)(1)(C)(4)
Training GISO, §5199.1(d)(9)
Quarantine order, due to an ATP infection, Disease control procedures  GISO, §5199.1(c)
Vaccinations, Medical Services GISO, §5199.1(d)(8)
Wildlife, Exposure to potentially infectious wildlife   GISO, §5199.1(b)
ANISIDINE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ANNUAL INSPECTIONS See under INSPECTIONS
ANNUAL MAINTENANCE
Fire Extinguisher GISO, §6151(e)(3)
ANNUAL TRAINING, Refresher 
Asbestos work See under ASBESTOS
Forklift, when required GISO, §3668(d)(1)
ANNUAL REPORTING
Injuries / OSHA Log 200 & Log 300 See CCR, Title 8, §14300.7
ANTENNAS, 3-30 MHz, Work on TelSO, §8614(g)
ANTHOPHYLLITE, Asbestiform See ASBESTOS
ANTHOPHYLLITE, Non-Asbestiform GISO, §5208.1
See Also CARCINOGENS, Regulated
Caution Signs  GISO, §5208.1(h) 
Caution Labels  GISO, §5208.1(i)
Change Rooms & Special Clothing  GISO, §5208.1(e)
Employee Information & Training  GISO, §5208.1(n) 
Training Program  GISO, §5208.1(n)(1)
Access to Training Materials  GISO, §5208.1(n)(2)
Employee Notification  GISO, §5208.1(k) 
Engineering Controls  GISO, §5208.1(b) 
Exposure Monitoring GISO, §5208.1(g)
Exposure Limits GISO, §5208.1(a)
Monitoring  GISO, §5208.1(g)(1)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Exposure Limits, Permissible GISO, §5208.1(a)
Laundering contaminated clothing  GISO, §5208.1(f)
Monitoring & Record Keeping  GISO, §5208.1(g)
Exposure Limits GISO, §5208.1(a)
Monitoring  GISO, §5208.1(g)(1)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Medical Surveillance  GISO, §5208.1(j) 
Medical Examinations   GISO, §5208.1(j)(1)
Record keeping    GISO, §5208.1(j)(2)
Notification of Employees GISO, §5208.1(k) 
Record Keeping  GISO, §5208.1(g)
Record Keeping  GISO, §5208.1(g)(2)
Records, Transfer of  GISO, §5208.1(m)
Reports of Use Per §5203  GISO, §5208.1(l) 
Permissible Exposure Limits GISO, §5208.1(a)
Respiratory Protective Equipment  GISO, §5208.1(d) 
Personal Protective Equipment
Respiratory Protective Equipment  GISO, §5208.1(d) 
Special Clothing  GISO, §5208.1(e)
Training & Employee Information  GISO, §5208.1(n) 
Training Program  GISO, §5208.1(n)(1)
Access to Training Materials  GISO, §5208.1(n)(2)
Transfer of Records  GISO, §5208.1(m)
Work Practices  GISO, §5208.1(c)
ANTI-KICKBACK DEVICES, Logging & Sawmill Operations LSSO, §6402, Appx A 
ANTIMONY, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ANTI-STATIC, Non-Conductive 
Blasting Packs, Avalanche GISO, §5356(e)
ANTI TWO-BLOCK DEVICE
Crane or Derrick Suspended Personnel Platforms GISO, §5004(e)(3)
Definition GISO, §4885
Load Safety Devices, Boom-Type Mobile Cranes GISO, §4924(d)
ANTU, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
APPAREL
Flame Resistant, High Voltage Electrical Work ESO-HV, §2940.6(j) 
Flame Resistant, Low Voltage Electrical Work ESO-LV, §2320.2(a)(8)
High Visibility Safety Apparel, exposed to Haulage Vehicles & Earth Moving Equipment  CSO, §1590(a)(5)
High Visibility Safety Apparel, Traffic Control   CSO, §1598(c), (d), (e)
High Visibility Safety Apparel, Flaggers CSO, §1599(d), (e), (f) 
APPEALS BOARD   See OSHAB Web Page
Citations & Penalties, Appeals of See OSHAB, §361(a)
  Definition   See OSHAB, §347(c)
Employee Appeals  See OSHAB, §361.1
Employer Appeals See OSHAB, §361
Filing of Appeals See OSHAB, §359(a)
Late Filing of See OSHAB, §359(b), (c) & (d)
Order to take Special Action, Appeals of See OSHAB, §361(b)
Special Order, Appeals of See OSHAB, §361(b)
APPLIANCES, per ESO ESO-LV, Article 52
Air conditioners
Electrical grounding  ESO-LV, §2395.45(a)(1)
Clothes dryers
Disconnection ESO-LV, §2522.23 
Electrical grounding ESO-LV, §2395.45(a)(2)
Clothes washers
Electrical grounding ESO-LV, §2395.45(a)(2)  
Combustible materials
Protection of  ESO-LV, §2522.10
Signals, appliance applied to combustible material ESO-LV, §2522. 12
Stand for appliance applied to combustible material ESO-LV, §2522. 11
Cooking Units, Counter-Mounted  ESO-LV, §2522.17
Counter-mounted cook-tops ESO-LV, §2522.17
Definition ESO-LV, §2300
Disconnection & Protection of Appliances 
Fixed appliances ESO-LV, §2522.21
Fixed electric space heaters ESO-LV, §2524.19
Location of disconnecting means ESO-LV, §2524.65
General Requirement ESO-LV, §2522.20 
Motor-driven appliances ESO-LV, §2522.26
Portable appliances ESO-LV, §2522.22
Stationary appliances ESO-LV, §2522.23
Dishwashers
Electrical grounding ESO-LV, §2395.45(a)(2)  
Electrical grounding See also Specific Appliance
Appliances connected by cord & plug ESO-LV, §2395.45
Alternating Current Circuits ESO-LV, §2395.5
Generators, Portable ESO-LV, §2395.6
Permanently wired ESO-LV, §2395.42
Electrically heated
Combustible materials, protection from ESO-LV, §2522.1(1) 
Energized parts of Appliances exposed to contact, prohibition ESO-LV, §2522.2
Fixed electric space heaters    See APPLIANCES, Space heaters 
Flexible cords & cables, use of ESO-LV, §2500.7
Freezers
Electrical grounding ESO-LV, §2395.45
Grounding, Electrical See also Specific Appliance
Appliances connected by cord & plug ESO-LV, §2395.45
Alternating Current Circuits ESO-LV, §2395.5
Direct Current Circuits ESO-LV, §2395.3
Generators, Portable ESO-LV, §2395.6
Permanently wired ESO-LV, §2395.42
Heated Appliances, Signals for ESO-LV, §2522.12
Marking of Heating Elements ESO-LV, §2522.31 
Heaters, Portable Immersion Type ESO-LV, §2522.9
Infrared Heating Lamp, Industrial Type ESO-LV, §2522.15
Installation ESO-LV, §2522.7
Approved manner ESO-LV, §2522.7
Immersion heaters
Current-carrying parts, insulation ESO-LV, §2522.9
Electrically Heated Appliances ESO-LV, §2522.10
Stands of Heated Appliances ESO-LV, §2522.11
Infrared Heating Lamp, Industrial Type ESO-LV, §2522.15
Ovens, wall-mounted ESO-LV, §2522.17
 Irons
Signals ESO-LV, §2522. 12
Stands ESO-LV, §2522.11
Markings ESO-LV, §2522.32
Rating Identified ESO-LV, §2522.32(a)
Alternative Method of Identifying Ratings ESO-LV, §2522.32(b)
Motor overload protection ESO-LV, §2522.30 
On Electrical Appliance Required ESO-LV, §2522.30
Rating Identified ESO-LV, §2522.30(a)
Visible / Easily Accessible ESO-LV, §2522.30(b)
Motor-driven appliances
Disconnection ESO-LV, §2522.26
Nameplates  ESO-LV, §2522.30
Motor overload protection, so Marked when so Required ESO-LV, §2522.30 
Nameplates for Electrical Appliance Required ESO-LV, §2522.30
Rating Identified ESO-LV, §2522.30(a)
Visible / Easily Accessible ESO-LV, §2522.30(b)
Markings on ESO-LV, §2522.32
Rating ESO-LV, §2522.32(a)
Alternative Method of Identifying Ratings ESO-LV, §2522.32(b)
Ovens, wall-mounted ESO-LV, §2522.17
Portable Appliances, Stands for ESO-LV, §2522.11
Portable heaters
Flexible cords See FLEXIBLE CORDS & CABLES, Electrical
Immersion heaters
Current-carrying parts, insulation ESO-LV, §2522.9
Ranges, disconnection ESO-LV, §2522.23
Refrigerators
Electrical grounding ESO-LV, §2395.45
Signals for Heated Appliances ESO-LV, §2522.12
Switches, indicating type ESO-LV, §2524.21
Voltage rating
Heating element labeling ESO-LV, §2522.31
Nameplates, on  ESO-LV, §2522.30 
Wall-mounted ovens  ESO-LV, §2522.17
APPLIANCES, Liquefied petroleum gas, per UFPV UFPVSO, §474 
APPLICATION EQUIPMENT, Securing of hoses, cables CSO, §1700 
APPLICATION FOR DIESEL ENGINE PERMIT, per TSO TSO, §8470(b)
APPROACH DISTANCES, to High Voltage Lines TelSO, §8602(h)
Alternative Means of Safety TelSO, §8602(h)(1) – (3)
APPROPRIATE
Clothing for work being done GISO, §3383(b) 
Guarding for the hazard involved GISO, §3942
APPROVALS, per CSO CSO, §1505
Definition of  CSO, §1505(a)
Alternative to CSO, §1505(c)
Equipment, Systems, Devices, of CSO, §1505(a)
Installations, Materials, of CSO, §1505(a)
Proof of CSO, §1505(b)
APPROVALS, Electrical Equipment, per ESO  ESO-LV, §2305.4
APPROVALS, Materials, Devices, & Systems, per GISO  GISO, §3206
Cylinders & Containers GISO, §4649(b)
Containers, Flammable Liquid GISO, §5532(a)
In spray coating operations  GISO, §5449(e)
Equipment supporting gas/oxygen mixing GISO, §4845(a)
AQUALIN, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
AQUARIUMS
Electrical grounding  for Electrical Equipment ESO-LV, §2395.45
AQUATIC AMUSEMENT RIDES PARSO, Article 3
See also AMUSEMENT RIDE SAFETY ORDERS, Permanent
Application PARSO, §3195.10
Operation & Maintenance  PARSO, §3195.11
ARASAN, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ARC FLASH, Electrical, Protection from
Flame Resistant Apparel, High Voltage Electrical Work ESO-HV, §2940.6(j) 
Flame Resistant Apparel, Low Voltage Electrical Work ESO-LV, §2320.2(a)(8)
ARCING PARTS, Electrical ESO-LV, §2340.18
Arcing or Suddenly Moving Parts, Protection ESO-LV, §2390.41
Combustible material, Separate from ESO-LV, §2340.18
Guarding suddenly moving parts ESO-LV, §2390.41(b)
Isolate from Combustible Materials ESO-HV, §2716.1
Shielding of Fuses / Circuit Breakers ESO-LV, §2390.41(a)
ARC WELDING & CUTTING, Inert Gas See also WELDING & CUTTING, Gas Systems
Inert-Gas Metal  GISO, §4853
See Also WELDING, Electric Welding, Cutting & Heating 
ARC WELDING, Electric Welding, Cutting & Heating GISO, Article 90
Application  GISO, §4850
Arc Welding Cutting & Heating GISO, §4851
Arc Welding, Inert-Gas Metal  GISO, §4853
Inert-Gas Metal Arc Welding GISO, §4853 
Installation of Equipment GISO, §4850(b)
Maintenance GISO, §4850(b)
Resistance Welding GISO, §4852
ARGON, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ARSENIC, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ARSENIC, Inorganic GISO, §5214
See Also CARCINOGENS, Regulated
Application & Scope GISO, §5214(a)
Definitions GISO, §5214(b)
Appendices GISO, §5214(q)
Application & Scope GISO, §5214(a)
Change Room GISO, §5214(i)
Compliance GISO, §5214(g)
Methods  GISO, §5214(g)
Written Program GISO, §5214(g) 
Employee Information & Training GISO, §5214(m) 
Exposure Monitoring  GISO, §5214(e)
Housekeeping GISO, §5214(j)
Hygiene Facilities & Practices GISO, §5214(k) 
Medical Surveillance GISO, §5214(n) 
Guidelines GISO, §5214, Appx C
Monitoring, Exposure GISO, §5214(e)
Observation of Monitoring  GISO, §5214(p)
Permissible Exposure Limit GISO, §5214(c)
Protective Clothing & Equipment GISO, §5214(i)
Record keeping  GISO, §5214(o)
Registration of Use Pursuant to §5203 GISO, §5214(d)
Regulated Areas  GISO, §5214(f)
Reporting of Incidents Pursuant to §5203 GISO, §5214(d)
Respiratory Protection GISO, §5214(h)
Signs & Labels GISO, §5214(l)
Substance technical guidelines GISO, §5214, Appx B
Technical Information Sheet GISO, §5214, Appx A, B
Training of employees GISO, §5214(m)
Warning Signs & Labels GISO, §5214(l)
Work practices GISO, §5214(g)
ARSINE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Process Safety Management GISO, §5189, Appx A
ASBESTOS, Operations Subject to CSO
Air sampling, mandatory procedure CSO, §1529, Appx A
Air sampling, non-mandatory procedure   CSO, §1529, Appx B
Application & Scope of Safety Orders CSO, §1529(a)
Definitions for the purpose of §1529 CSO, §1529(b)
Asbestos Containing Material, Definition of CSO, §1529(b)
Building Owner, Duties of  CSO, §1529(k)(2)  
Certified Asbestos Consultants CSO, §1529(b), (q)     
Change Room  CSO, §1529(j)
Cleaning, Housekeeping  CSO, §1529(l)
Flooring, Care of CSO, §1529(l)(3)
Vacuuming CSO, §1529(l)(1)
Waste Disposal CSO, §1529(l)(2)
Clean-up, Asbestos Containing Materials of CSO, §1529(a)
Prompt Cleanup, Housekeeping CSO, §1529(g)(1)(C)
Wet Method CSO, §1529(g)(1)(B)
Communication of hazards to employee  CSO, §1529(k)    
Competent person CSO, §1529(b), (d)-(g), (i), (k), (o)    
Compressed air, prohibition of used   CSO, §1529(g)(3)  
Consultants, Certified  CSO, §1529(q)   
Contaminated Clothing CSO, §1529.2), (3)
  Laundering of CSO, §1529(i)(2)
Decontamination areas CSO, §1529(j)(1), (2), (3)  
Demolition of structures CSO, §1529(a)  
Emergencies CSO, §1529(a)
Employee Hazard Awareness CSO, §1529(f)(5) 
                    CSO, §1529, Appx H
  Training     CSO, §1529(k)(9)
Encapsulation of Asbestos Containing Materials CSO, §1529(a)  
Engineering controls to reduce exposure CSO, §1529(g)(1)
Non-mandatory standards CSO, §1529, Appx F
Exposure limit, as airborne carcinogen   GISO, §5155, & Appx A    
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Exposure limit, Permissible CSO, §1529(c)
Exposure Monitoring/Assessment  CSO, §1529(f)  
Facility Owner, Duties of  CSO, §1529(k)(2)  
Flooring materials, Care of  CSO, §1529(l)
Flooring materials, removal of  CSO, §1529(g)(8)(A)
Gasket materials, removal  CSO, §1529(g)(8)(D)
Glove bags  CSO, §1529(g)(5)
Glove box, Negative Pressure CSO, §1529(g)(5)(D)
HEPA filtration systems, 
Class I Work, Non-mandatory CSO, §1529, Appx F 
Negative Pressure Enclosures  CSO, §1529(g)(5)(A)
Negative Pressure Glove bag CSO, §1529(g)(5)(C) 
Negative Pressure Glove box CSO, §1529(g)(5)(D) 
HEPA Vacuums CSO, §1529(g), (j)
Housekeeping (Cleaning) requirements  CSO, §1529(l)
HVAC System Isolation CSO, §1529(g)(4)(C)
Hygiene facilities in work areas  CSO, §1529(j), 
Non-mandatory CSO, §1529, Appx F
Information, Hazard Awareness CSO, §1529(f)(5) 
                    CSO, §1529, Appx H
  Training        CSO, §1529(k)(9)
Labels on Materials (Products)  CSO, §1529(k)(8)
Laundering of Work Clothing CSO, §1529(i)(2)
Vacuuming before Removal  CSO, §1529(j)(2)(C)
Medical questionnaires  CSO, §1529, Appx D, I
Medical surveillance of employees on work sites CSO, §1529(m)
Chest X-rays, Interpretation of CSO, §1529, Appx E
Frequency of CSO, §1529(m)(2)
Guidelines  CSO, §1529, Appx I
Medical Exam Content CSO, §1529(m)(2)(B)
Monitoring, Exposure  CSO, §1529(f)
Multi-employer worksites  CSO, §1529(k)(2)(B)
Negative Exposure Assessment  CSO, §1529(f)(1)(B), (C) 
Negative-pressure enclosures  CSO, §1529(g)(5)(A) 
Alternative, For Class I Work CSO, §1529(g)(4)(F)
Class I Work CSO, §1529, Appx F
Glove bag CSO, §1529(g)(5)(C)
Glove box CSO, §1529(g)(5)(D)
Notifications, Presence of Asbestos  CSO, §1529(k)
Observation of Monitoring CSO, §1529(b)    
Permissible Exposure Limits  CSO, §1529(c)
Polarized light microscopy  CSO, §1529, Appx K
Prohibitions CSO, §1529(g)(3)
Presumed Asbestos Containing Material, Definition of CSO, §1529(b)
Protective clothing  CSO, §1529(i)
Laundering of CSO, §1529(i)(2)
Record keeping requirements   CSO, §1529(n)
Regulated Areas   CSO, §1529(b), (e) 
Access to  CSO, §1529(e)(3)
Demarcation of CSO, §1529(e)(2)
Removal of Asbestos Containing Materials CSO, §1529(a)  
Removal procedures  CSO, §1529(b)
             CSO, §1529(g)
             CSO, §1529, Appx F
Renovation of structures containing  CSO, §1529(a)
Reporting requirements CSO, §1529(r) 
Respirator protection  CSO, §1529(h)
             CSO, §1529, Appx H
Fit Testing, Reference to GISO, §5144 CSO, §1529, Appx C
Roofing materials, removal  CSO, §1529(g)(8)(B)
Salvage of structures CSO, §1529(a)  
Sampling, Air  CSO, §1529(g)(4), (7), (9)
Procedures CSO, §1529, Appx A, B & K
Siding materials, removal  CSO, §1529(g)(8)(C)
Signs  CSO, §1529(k)(7)
Site Surveillance Technicians  CSO, §1529(b), (q)     
Smoking cessation program CSO, §1529, Appx J
Technical information CSO, §1529, Appx H
Temporary worksites, Reporting requirements  CSO, §1529(r)
Training of employees  CSO, §1529(k)(9)
Vacuum cleaners, HEPA CSO, §1529(g)(1)(A)
Ventilation requirements  CSO, §1529(g)(2)
             CSO, §1529, Appx F
Warning signs near regulated areas  CSO, §1529(k)(7)
Waste disposal  CSO, §1529(l)(2)
Non-mandatory standards  CSO, §1529, Appx F
Prompt CSO, §1529(g)(1)(C)
Waste disposal Bags, Specification CSO, §1529(g)(5)(D)
Work Clothing, Cleaning CSO, §1529(j)(2)(C)
Laundering of CSO, §1529(i)(2)
Work, registration    See Cal/OSHA, §341.6
ASBESTOS, Operations Subject to GISO  GISO, §5208
See Also CARCINOGENS, Regulated
Application & Scope of GISO, §5208(a)
Definitions for the purpose of §5208 GISO, §5208(b)
Appendices, Application of  GISO, §5208(p)
Asbestos Containing Material, Definition of GISO, §5208(b)
Brake Repair, Compliance methods GISO, §5208(f)(3)
Change Room  GISO, §5208(h), (i)
  Clutch Repair, Compliance methods GISO, §5208(f)(3)
Communication of Hazards to Employees  GISO, §5208(j)
Criteria to rebut the designation as PACM  GISO, §5208(j)(8)
Duties of Building & Facility Owners  GISO, §5208(j)(2)
Duties of Employers GISO, §5208(j)(2)
Employee Information & Training  GISO, §5208(j)(7)
Installed Asbestos Containing Material  GISO, §5208(j)(1)
Material Safety Data Sheets  GISO, §5208(j)(5)
Warning labels  GISO, §5208(j)(4) & (6)
Warning signs  GISO, §5208(j)(3)
Exposure monitoring  GISO, §5208(d)
Additional monitoring  GISO, §5208(d)(5)
  Changes in monitoring frequency  GISO, §5208(d)(4)
General Requirements GISO, §5208(d)(1)
Initial monitoring  GISO, §5208(d)(2)
Method of monitoring  GISO, §5208(d)(6)
Monitoring frequency & Patterns  GISO, §5208(d)(3)
Housekeeping  GISO, §5208(k)
  Compressed air cleaning Prohibited  GISO, §5208(g)(1)
  Dry sweeping & Clean-up Limit GISO, §5208(g)(1)
Dry sweeping Prohibition GISO, §5208(g)(1)
Flooring, Care of  GISO, §5208(g)(1)
HEPA-filtered vacuuming equipment GISO, §5208(g)(1)
Shoveling Limit GISO, §5208(g)(1)
Spills & Releases  GISO, §5208(g)(1)
Surfaces  GISO, §5208(g)(1)
  Vacuuming without HEPA Filter Prohibited  GISO, §5208(g)(1)
Waste disposal  GISO, §5208(g)(1)
Hygiene Facilities & Practices  GISO, §5208(i)
Change rooms  GISO, §5208(i)(1)
Lunchrooms  GISO, §5208(i)(3)
  Showers  GISO, §5208(i)(2)
Smoking in Work Areas  GISO, §5208(i)(4)
Medical surveillance  GISO, §5208(l)
General  GISO, §5208(l)(1)
Frequency of GISO, §5208(l)(3)
Interpretation of X-Rays GISO, §5208, Appx E
Information provided to the physician  GISO, §5208(l)(6)
Periodic Physical / Examinations GISO, §5208(l)(3)
Physician's Written Opinion  GISO, §5208(l )(7)
Pre-placement Physical / Examinations  GISO, §5208(l)(2)
Recent Physical / Examinations GISO, §5208(l)(5)
Termination Physical / Examinations GISO, §5208(l)(4)
Methods of compliance  GISO, §5208(f)
Compliance program  GISO, §5208(f)(2)
Brake & Clutch Repair GISO, §5208(f)(3)
Engineering controls & Work Practices  GISO, §5208(f)(1)
Observation of Monitoring  GISO, §5208(n)
Permissible exposure limit (PELS)  GISO, §5208(c)
Excursion limit  GISO, §5208(c)(2)
Time-weighted average limit (TWA)  GISO, §5208(c)(1)
Presumed Asbestos Containing Material, Definition of GISO, §5208(b)
Protective Work Clothing & Equipment  GISO, §5208(h)
Cleaning of GISO, §5208(h)(3)
Provision & Use  GISO, §5208(h)(1)
Removal of  GISO, §5208(h)(2)
Replacement of  GISO, §5208(h)(3)
Storage of GISO, §5208(h)(2)
Record keeping  GISO, §5208(m)
Availability of Records  GISO, §5208(m)(5)
Exposure Measurements, of  GISO, §5208(m)(1)
Medical surveillance, of GISO, §5208(m)(3)
Objective Data for Exempted Operations  GISO, §5208(m)(2)
Training, of GISO, §5208(m)(4)
Transfer of Records  GISO, §5208(m)(6)
Regulated Areas  GISO, §5208(e)
Access to GISO, §5208(e)(3)
Demarcation  GISO, §5208(e)(2) 
  Establishment of GISO, §5208(e)(1)
Prohibited Activities  GISO, §5208(e)(5)
Respirators, Provision of GISO, §5208(e)(4)
Reports of use  GISO, §5208(o)
Respiratory protection  GISO, §5208(g)
General Requirements GISO, §5208(g)(1) 
Respirator program GISO, §5208(g)(2)
Respirator Selection GISO, §5208(g)(3) 
Fit Testing, Reference to GISO §5144 GISO, §5208, Appx C
Waste Disposal  GISO, §5208(k)(6)
ASBESTOS, Operations Subject to SSO SSO, §8358
Application & Scope of Safety Orders SSO, §8358(a)
Definitions for the purpose of §8358 SSO, §8358(b)
Air sampling, mandatory procedure SSO, §8358, Appx A
Air sampling, non-mandatory procedure   SSO, §8358, Appx B
Asbestos Containing Material, Definition of SSO, §8358(b)
Certified Industrial Hygienist SSO, §8358(b)
Change Room  SSO, §8358(j)
Cleaning, Housekeeping  SSO, §8358(l)
Deck, Care of Material SSO, §8358(l)(3)
Flooring, Care of Material SSO, §8358(l)(3)
Vacuuming SSO, §8358(l)(1)
Waste Disposal SSO, §8358(g)(1)(C)
Clean-up, Asbestos Containing Materials of SSO, §8358(a)
Prompt Cleanup, Housekeeping SSO, §8358(g)(1)(C)
Wet Method SSO, §8358(g)(1)(B)
Communication of hazards to employee SSO, §8358(k)    
Competent person SSO, §8358(b), (d)-(g), (i)
Compressed air, prohibition of used   SSO, §8358(g)(3)  
Contaminated Clothing SSO, §8358(i)(2), (3)
  Laundering of SSO, §8358(i)(2)
Decontamination areas SSO, §8358(j)(1), (2), (3)  
Demolition of structures SSO, §8358(a)  
Emergencies SSO, §8358(a)
Employee Hazard Awareness SSO, §8358(f)(5) 
                    SSO, §8358, Appx H
  Training       SSO, §8358(k)(9)
Encapsulation of Asbestos Containing Materials SSO, §8358(a)  
Engineering controls to reduce exposure SSO, §8358(g)(1)
Non-mandatory standards SSO, §8358, Appx F
Exposure limit, as airborne carcinogen   GISO, §5155, & Appx A    
Exposure limit, Permissible SSO, §8358(c)
Exposure Monitoring/Assessment  SSO, §8358(f)  
Facility Owner, Duties of  SSO, §8358(k)(2)  
Flooring materials, Care of  SSO, §8358(l)
Flooring materials, removal of  SSO, §8358(g)(8)(A)
Gasket materials, removal  SSO, §8358(g)(8)(D)
Glove bags  SSO, §8358(g)(5)
Glove box, Negative Pressure SSO, §8358(g)(5)(D)
HEPA filtration systems  SSO, §8358, Appx F 
Class I Work, Non-mandatory SSO, §8358(g)(5)(A)
Negative Pressure Enclosures  SSO, §8358(g)(5)(C) 
Negative Pressure Glove bag SSO, §8358(g)(5)(D) 
Negative Pressure Glove box SSO, §8358(g), (j)
HEPA Vacuums
Housekeeping (Cleaning) requirements  SSO, §8358(l)
HVAC System Isolation SSO, §8358(g)(4)(C)
Hygiene facilities in work areas  SSO, §8358(j), 
Non-mandatory SSO, §8358, Appx F
Information, Hazard Awareness SSO, §8358(f)(5) 
                    SSO, §8358, Appx H
  Training        SSO, §8358(k)(9)
Labels on Materials (Products)  SSO, §8358(k)(8)
Laundering of Work Clothing SSO, §8358(i)(2)
Vacuuming before Removal  SSO, §8358(j)(2)(C)
Medical questionnaires  SSO, §8358, Appx D, I
Medical surveillance of employees on work sites SSO, §8358(m)
Chest X-rays, Interpretation of SSO, §8358, Appx E
Guidelines  SSO, §8358, Appx I
Medical Exam Content SSO, §8358(m)(2)
Monitoring, Exposure  SSO, §8358(f)
Multi-employer worksites  SSO, §8358(k)(2)(B)
Negative Exposure Assessment  SSO, §8358(f)(1)(B), (C) 
Negative-pressure enclosures  SSO, §8358(g)(5)(A) 
Alternative, For Class I Work SSO, §8358(G)(4)(F)
Class I Work SSO, §8358, Appx F
Glove bag SSO, §8358(g)(5)(C)
Glove box SSO, §8358(g)(5)(D)
Notifications, Presence of Asbestos  SSO, §8358(k)
Observation of Monitoring SSO, §8358(b)    
Permissible Exposure Limits  SSO, §8358(c)
Polarized light microscopy  SSO, §8358, Appx K
Presumed Asbestos Containing Material, Definition of SSO, §8358 (b)
Prohibitions SSO, §8358(g)(3)
Protective clothing  SSO, §8358(i)
Laundering of SSO, §8358(i)(2)
Record keeping requirements   SSO, §8358(n)
Regulated Areas   SSO, §8358(b), (e) 
Access to  SSO, §8358(e)(3)
Demarcation of SSO, §8358(e)(2)
Removal of Asbestos Containing Materials SSO, §8358(a)  
Removal procedures  SSO, §8358(b)
             SSO, §8358(g)
             SSO, §8358, Appx F
Renovation of structures containing  SSO, §8358(a)
Reporting requirements SSO, §8358(r) 
Respirator protection  SSO, §8358(h)
             SSO, §8358, Appx H, III
Fit Testing, Reference to GISO §5144 SSO, §8358, Appx C
Roofing materials, removal  SSO, §8358(g)(8)(B)
Salvage of structures SSO, §8358(a)  
Sampling, Air  SSO, §8358(g)(4), (7), (9)
Procedures SSO, §8358, Appx A, B & K
Siding materials, removal  SSO, §8358(g)(8)(C)
Signs  SSO, §8358(k)(7)
Site Surveillance Technicians  SSO, §8358(b), (q)     
Smoking cessation program SSO, §8358, Appx J
Technical information SSO, §8358, Appx H
Temporary worksites, Reporting requirements  SSO, §8358(r)
Training of employees  SSO, §8358(k)(9)
Vacuum cleaners, HEPA SSO, §8358(g)(1)(A)
Ventilation requirements  SSO, §8358(g)(2)
             SSO, §8358, Appx F
Vessel/Building/Facility Owner, Duties of  SSO, §8358(k)(2)  
Warning signs near regulated areas  SSO, §8358(k)(7)
Waste disposal  SSO, §8358(g)(1)(C)
             SSO, §8358, Appx F
Waste disposal Bags, Specification SSO, §8358(g)(5)(D)
Clothing, Cleaning SSO, §8358(j)(2)(C)
Laundering of SSO, §8358(i)(2)
ASPHALT BUCKETS & KETTLES, Asphalt /Hot Mopped Roofing
Asphalt Fumes, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
Asphalt & Pitch Kettles CSO, §1726
Buckets, Kettles & Tankers, Handling of CSO, §1725
Handling CSO, §1725
Hot Asphalt & Hot Pitch Buckets  CSO, §1729
Kettles Mounted on Elevated Truck Beds  CSO, §1727
Specifications of Kettles CSO, §1726(a)-(c)
Specifications of Buckets and Gallows-Type Frames CSO, §1729
Fire Extinguisher CSO, §1726(d)
Mounted on Truck Beds CSO, §1727
Tar Pitch, Handling of CSO, §1728
ASPHALT FUMES, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ASPHYXIANTS, in Breathing Air GISO, §5144(i)
Acrylonitrile GISO, §5213
Storage of GISO, §5164
ASPIRIN, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ASSEMBLY, Halls or Places of
Application / Scope ESO-LV, §2551.1
Emergency Power Systems, Control,  per Article 80 ESO-LV, §2551.2(c)
Hazardous Locations  per Article 59 ESO-LV, §2551.2(a)
Storage of Class I, Class II & Class IIIA Liquids  GISO, §5537
Temporary Wiring, per Article 13 ESO-LV, §2551.2(b)
Wiring Methods ESO-LV, §2551.3
ASSESSMENT, Safety See also Specific Work Activity, Substance, Process
Construction Operations, Before Employees Presence CSO, §1511(b)
Workplace Hazard Assessment, under IIPP  GISO, §3203(a)(4)  
Workplace Hazard Assessment, PPE Selection  GISO, §3380(f)
Employer's Written Certification GISO, §3380(f)(2)
Examples of Assessment Procedures GISO, §3380, Appx A
Personal Protective Devices, Equipment Selection GISO, §3380(f) 
Communicate to Effected Employee GISO, §3380(f)(1)(B)
Damaged/Defective PPE GISO, §3380(f)(3)
Properly Fitted PPE GISO, §3380(f)(1)(C)
Select PPE GISO, §3380(f)(1)(A)
Training  GISO, §3380(f)(4)
ASSURED EQUIPMENT GROUNDING CONDUCTOR PROGRAM ESO-LV, §2405.4(d)
Identification of Tested Equipment & Test Dates ESO-LV, §2405.4(d)(7)
Inspection of Equipment in AEGCP ESO-LV, §2405.4(d)(3)
Prohibited Use of Equipment  ESO-LV, §2405.4(d)(6)
Qualified person(s) to implement  ESO-LV, §2405.4(d)(1)
Testing Requirement ESO-LV, §2405.4(d)(4)
Test Intervals ESO-LV, §2405.4(d)(5)
Written program ESO-LV, §2405.4(d)(1)
ATMOSPHERE, Contaminated  GISO, §5159(a), (b)
ATMOSPHERE, Explosive
Powder-actuated tool use prohibited,  CSO, §1690
ATMOSPHERIC CONDITIONS, Protection of Equipment from ESO-HV, §2712
ATMOSPHERIC VENTS, Fire Prevention Requirements PSO-R,T&H, §6778
ATRAZINE, Airborne Contaminant, Exposure limit  GISO, §5155, & Appx A  
Listed, Permissible Exposure Limits GISO, §5155, Table AC-1
ATTACHMENT PLUGS, Non-Grounding Type Electrical  ESO-LV, §2510.58
ATTENDANCE, Boilers  B&FPV, §781 
ATTENDANT, Amusement Rides, Training PARSO, §3195.7(a)
ATTENDANT, at Joint Power & Tele-com Man Holes  TelSO, §8616(d)
ATTENUATION, Calculated GISO, §5098
ATTIC, Access Openings GISO, §3271
AUDIOMETRIC TEST PROGRAM GISO, §5097(c)
Audiogram Requirements per    §5097 Appx B GISO, §5097(c)(4)
Audiology Technician, Certification Requirement GISO, §5097(c)(3)
Baseline Requirement GISO, §5097(c)(5)
Baseline Requirements, Employee Notification GISO, §5097(c)(7)
Baseline Requirements, Employee Noise Exposure Limits GISO, §5097(c)(6)
Employee, Testing at no cost to GISO, §5097(c)(2)
Employer Responsibility GISO, §5097(c)(1), (2)
Employee Notification of Testing Results  GISO, §5097(c)(8)
Testing Performed By  GISO, §5097(c)(3)
Testing Results, Employee Notification of  GISO, §5097(c)(8)
AUGERS
Cotton Gins, Screw Conveyors GISO, §4647
Drilling Operations MSO, §7005(h)
Mixing Auger, Agricultural Operations GISO, §3440(g)
Pomace Pumps, Wine GISO, §4539
Post Hole Diggers, Controls of GISO, §4086
Screw Conveyors GISO, §3446
Wine Pomace Pumps GISO, §4539
AUTHORIZED PERSON, Energized Equipment / Systems  ESO-LV, §2320.2(b)
AUTO BODY SHOP, Hazardous Locations (Classified)  ESO-LV, §2540.9
AUTOMATIC, 
Circuit Reclosers  ESO-HV, §2843
Couplers, Locomotive Cranes GISO, §4927(b) 
Lathes, Wood Working GISO, §4319 
Restarting Motors, Electrical ESO-LV, §2530.43
Return, radial arm saw GISO, §4309(d)
Start, warning signs GISO, §3320
AUTOMOBILES    See MOTOR VEHICLES 
AUTOMOTIVE LIFTS GISO, Article 19
Definition, Automotive Lift GISO, §3541
Air Tank, Working Pressure & Corrosion Protection GISO, §3546
Control Mechanism GISO, §3544
Descent Speed GISO, §3549
Design GISO, §3542(a)-(c)
Inspection, Operation, Maintenance GISO, §3542(d)
Marking / Labeling Requirements GISO, §3543 
Oil Measurement GISO, §3545
Oil Tank, Working Pressure & Corrosion Protection GISO, §3546
Working Area, Under Lift GISO, §3547
Supports, Chassis & Axle GISO, §3548
AUTOMOTIVE MAINTENANCE
  See also SERVICE STATIONS
Brake Repair, Asbestos Compliance Method GISO, §5208(f)(3)
Maintenance & Repair  GISO, §3328
Tire Inflation  GISO, §3325
Tire Repair, Split Rim Wheels GISO, §3326
Fueling, Internal Combustion Engines GISO, §3319 
Gasoline Dispenser, Hazardous Locations (Classified)  ESO-LV, §2540.7
AVAILABILITY, of Medical personnel  GISO, §3400(a)
AVALANCHE, Snow Blasting GISO, Article 121
Arming of Explosive Charges GISO, §5355
Arming Room, Inside GISO, §5355(c)
Deployment Site, at  GISO, §5355(b)
Arming Room GISO, §5355.1  
Construction of  GISO, §5355.1(b)
Housekeeping GISO, §5355.1(d)
Location of  GISO, §5355.1(a)
Restrictions GISO, §5355.1(c)
Avalanche control coordinator   GISO, §5351(a)
Blaster in charge GISO, §5351(b), (c) 
Competent ski mountaineers GISO, §5351(f)
Consist of GISO, §5351(d)
Personnel in training  GISO, §5351(e)
Blasting Activities GISO, §5357
Avalauncher / Launcher, use of GISO, §5357(e)
General Requirements GISO, §5357(a) 
Hand Deployment GISO, §5357(b)
Helicopter, from GISO, §5357(d)
Ski lifts or trams, from GISO, §5357(c)
Blasting caps GISO, §5353(a), (c)
Blasting Packs, Avalanche GISO, §5356(e)
Cap & Fuse Assembly GISO, §5353(e)
Communication requirement GISO, §5351(g)
Detonating Systems GISO, §5353(a)
Explosives GISO, §5352
Shelf life of  GISO, §5352(a) 
Storage of GISO, §5354
Transporting of GISO, §5356
Weather resistance  GISO, §5352(b) 
Fuse caps GISO, §5353(c) 
Fuse Igniter GISO, §5353(f)
Misfired Explosives GISO, §5358