Chemical
Abstracts
Registry
Number (a) |
Skin(b) |
Name(c) |
PEL
(d)
|
|
STEL
(o)
|
| ppm(e) |
mg/M3(f) |
Ceiling(g) |
ppm(e) |
mg/M3(f) |
|
|
75070 |
|
Acetaldehyde |
25 |
45 |
C |
|
|
|
64197 |
|
Acetic acid |
10 |
25 |
40 ppm |
15 |
37 |
|
108247 |
|
Acetic Anhydride |
5 |
20 |
C |
|
|
|
67641 |
|
Acetone |
500 |
1200 |
3000 ppm |
750 |
1780 |
|
75868 |
|
Acetone cyanohydrin as CN |
4.7 |
5 |
C |
|
|
|
75058 |
S |
Acetonitrile |
40 |
70 |
|
60 |
105 |
|
98862 |
|
Acetophenone |
10 |
49 |
|
|
|
|
53963 |
S |
2-Acetylaminofluorene; N-fluoren-2-yl acetamide; |
|
|
|
|
|
|
|
|
|
see Section 5209 |
|
|
|
|
|
|
74862 |
|
Acetylene |
(h) |
|
|
|
|
|
540590 |
|
Acetylene dichloride; see 1,2-Dichloroethylene |
|
|
|
|
|
|
79276 |
|
Acetylene tetrabromide:1,1,2,2-tetrabromoethane |
1 |
14 |
|
|
|
|
79345 |
|
Acetylene tetrachloride; see 1,1,2,2- |
|
|
|
|
|
|
|
|
|
Tetrachloroethane |
|
|
|
|
|
|
50782 |
|
Acetylsalicylic acid (Aspirin) |
|
5 |
|
|
|
|
107028 |
S |
Acrolein |
0.1 |
0.25 |
C |
|
|
|
79061 |
S |
Acrylamide |
-- |
0.03 |
|
|
|
|
79107 |
S |
Acrylic acid |
2 |
5.9 |
|
|
|
|
107131 |
S |
Acrylonitrile; see Section 5213 |
2 |
4.5 |
|
|
|
|
124049 |
|
Adipic acid |
-- |
5 |
|
|
|
|
111693 |
S |
Adiponitrile |
2 |
8.8 |
|
|
|
|
309002 |
S |
Aldrin; 1,2,3,4,10,10-hexachloro-1,4,4a,5,8,8a- |
|
|
|
|
|
|
|
|
|
hexahydro-endo-1,2-exo-5,8- |
|
|
|
|
|
|
|
|
|
dimethanonaphthalene |
-- |
0.25 |
|
|
|
|
107186 |
S |
Allyl alcohol |
0.5 |
1.25 |
|
4 |
10 |
|
107051 |
|
Allyl chloride |
1 |
3 |
|
2 |
6 |
|
106923 |
S |
Allyl glycidyl ether; AGE |
5 |
22 |
|
10 |
44 |
|
2179591 |
|
Allyl propyl disulfide |
2 |
12 |
|
3 |
18 |
|
1344281 |
|
Alumina; see Particulates not otherwise regulated |
|
|
|
|
|
|
|
|
Aluminum, alkyls (not otherwise classified) |
-- |
2 |
|
|
|
|
|
|
Aluminum soluble salts |
-- |
2 |
|
|
|
|
|
|
Aluminum metal and oxide |
-- |
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5(n) |
|
|
|
|
|
|
Aluminum pyro powders |
-- |
5 |
|
|
|
|
|
|
Aluminum welding fumes |
-- |
5 |
|
|
|
|
300925 |
|
Aluminum distearate |
-- |
10 |
|
|
|
|
7047849 |
|
Aluminum stearate |
-- |
10 |
|
|
|
|
637127 |
|
Aluminum tristearate |
-- |
10 |
|
|
|
|
1300738 |
|
Aminodimethylbenzene; see Xylidene |
|
|
|
|
|
|
92671 |
S |
4-Aminodiphenyl; see Section 5209 |
|
|
|
|
|
|
141435 |
|
2-Aminoethanol; see Ethanolamine |
|
|
|
|
|
|
91598 |
|
2-Aminonapthalene; see beta-Naphthylamine, |
|
|
|
|
|
|
|
|
|
Section 5209 |
|
|
|
|
|
|
504290 |
|
2-Aminopyridine |
0.5 |
2 |
|
|
|
|
61825 |
|
Amitrole |
-- |
0.2 |
|
|
|
|
7664417 |
|
Ammonia |
25 |
18 |
|
35 |
27 |
|
3825261 |
S |
Ammonium perfluorooctanoate |
-- |
00.1 |
|
|
|
|
12125029 |
|
Ammonium chloride fume |
-- |
10 |
|
-- |
20 |
|
1002897 |
|
Ammonium stearate |
-- |
10 |
|
|
|
|
7773060 |
|
Ammonium sulfamate |
-- |
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5 |
|
|
|
|
620111 |
|
3-Amyl acetate; See Pentyl acetate |
|
|
|
|
|
|
628637 |
|
n-Amyl acetate; See Pentyl acetate |
|
|
|
|
|
|
626380 |
|
sec-Amyl acetate (all isomers and mixtures); See Pentyl acetate |
|
|
|
|
|
|
625161 |
|
tert-Amyl acetate; See Pentyl acetate |
|
|
|
|
|
62533 |
S |
Aniline |
2 |
7.6 |
|
|
|
|
29191524 |
S |
Anisidine (ortho and para isomers) |
0.1 |
0.5 |
|
|
|
|
|
|
Antimony and compounds, as Sb |
-- |
0.5 |
|
|
|
|
86884 |
|
ANTU; 1-(1-naphthyl)-2-thiourea; Bantu; Rattrack |
-- |
0.3 |
|
|
|
|
7440371 |
|
Argon |
(h) |
|
|
|
|
|
7440382 |
|
Arsenic and inorganic arsenic compounds; see also |
|
0.01 |
|
|
|
|
|
|
|
Section 5214 |
|
|
|
|
|
|
|
|
Arsenic, organic compounds, as As |
-- |
0.2 |
|
|
|
|
7784421 |
|
Arsine; AsH3 |
0.05 |
0.2 |
|
|
|
|
1332-21-4 |
|
Asbestos (including actinolite, amosite |
|
|
|
|
|
|
|
|
|
anthophyllite, chrysotile, crocidolite, and tremolite); |
|
|
|
|
|
|
|
|
|
see Section 5208 |
|
|
|
|
|
|
8052424 |
|
Asphalt (petroleum) fumes |
-- |
5 |
|
|
|
|
1912249 |
|
Atrazine |
-- |
5 |
|
|
|
|
86500 |
S |
Azinphos methyl; o,o-dimethyl S-(4-oxo-1,2,3- |
-- |
0.2 |
|
|
|
|
|
|
|
benzotriazin-3(4H)-ylmethyl) phosphorodithioate |
|
|
|
|
|
|
3333526 |
S |
2,2'-Azobisisobutyronitrile decomposition product, |
|
|
|
|
|
|
|
|
|
see Tetramethyl succinonitrile |
|
|
|
|
|
|
7440393 |
|
Barium, soluble compounds, as Ba |
-- |
0.5 |
|
|
|
|
7727437 |
|
Barium sulfate; see Particulates not otherwise regulated |
|
|
|
|
|
|
17804352 |
|
Benomyl |
|
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5 |
|
|
|
|
71432 |
S |
Benzene; see also Section 5218 |
1 |
|
|
5 |
-- |
|
92875 |
S |
Benzidine; 4,4'-diaminobiphenyl, see Section 5209 |
|
|
|
|
|
|
71432 |
|
Benzol; see Benzene |
|
|
|
|
|
|
106514 |
|
D-Benzoquinone; see Quinone |
|
|
|
|
|
|
98884 |
|
Benzoyl chloride |
0.2 |
1.1 |
C |
|
|
|
94360 |
|
Benzoyl peroxide; dibenzoyl peroxide |
-- |
5 |
|
|
|
|
140114 |
|
Benzyl acetate |
10 |
61 |
|
|
|
|
100447 |
|
benzyl chloride; alpha-chlorotoluene |
1 |
5 |
|
|
|
| 7440417 |
|
Beryllium, and beryllium compounds as Be |
-- |
0.0002 |
0.025mg/M3 |
-- |
|
|
92524 |
|
Biphenyl; diphenyl; phenylbenzene |
0.2 |
1.5 |
|
|
|
|
542881 |
|
Bis(chloromethyl) ether, see bis-Chloromethyl ether, |
|
|
|
|
|
|
|
|
|
Section 5209 |
|
|
|
|
|
|
3033623 |
S |
Bis (Dimethylaminoethyl) ether (DMAEE) |
0.05 |
0.328 |
|
0.15 |
0.983 |
|
1304821 |
|
Bismuth telluride |
|
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5 |
|
|
|
|
|
|
Bismuth telluride (selenium-doped) |
-- |
5 |
|
|
|
|
|
|
Borates, tetra, sodium salts |
|
|
|
|
|
|
|
|
|
Anhydrous |
-- |
5 |
|
|
|
|
|
|
|
Decahydrate |
-- |
5 |
|
|
|
|
|
|
|
Pentahydrate |
-- |
5 |
|
|
|
|
1303862 |
|
Boron oxide |
-- |
10 |
|
|
|
|
10294334 |
|
Boron tribromide |
1 |
10 |
C |
|
|
|
7637072 |
|
Boron trifluoride |
1 |
3 |
C |
|
|
|
314409 |
|
Bromacil |
1 |
10 |
|
|
|
|
7726956 |
|
Bromine |
0.1 |
0.7 |
C |
|
|
|
7789302 |
|
Bromine pentafluoride |
0.1 |
0.7 |
|
|
|
|
74975 |
|
Bromochloromethane; see Chlorobromethane |
|
|
|
|
|
|
74964 |
|
Bromoethane; see Ethyl bromide |
|
|
|
|
|
|
75252 |
S |
Bromoform; tribromomethane |
0.5 |
5 |
|
|
|
|
74839 |
|
Bromomethane, see Methyl bromide |
|
|
|
|
|
|
75638 |
|
Bromotrifluoromethane; see Trifluorobromomethane |
|
|
|
|
|
|
106990 |
|
1,3-Butadiene (see also section 5201) |
1 |
2.2 |
|
5 |
11 |
|
106978 |
|
Butane |
800 |
1,900 |
|
|
|
|
109795 |
|
1-Butanethiol; see Butyl mercaptan |
|
|
|
|
|
|
71363 |
|
1-Butanol; see n-Butyl alcohol |
|
|
|
|
|
|
78933 |
|
2-Butanone; see Methyl ethyl ketone |
|
|
|
|
|
|
111762 |
S |
2-Butoxyethanol (EGBE) |
20 |
97 |
|
|
|
|
123864 |
|
n-Butyl acetate |
150 |
710 |
|
200 |
950 |
|
105464 |
|
sec-Butyl acetate |
200 |
950 |
|
|
|
|
540885 |
|
tert-Butyl acetate |
200 |
950 |
|
|
|
|
141322 |
|
Butyl acrylate |
2 |
11 |
|
|
|
|
71363 |
S |
n-Butyl alcohol; 1-butanol |
50 |
150 |
C |
|
|
|
78922 |
|
sec-Butyl alcohol |
100 |
305 |
|
|
|
|
75650 |
|
tert-Butyl alcohol |
100 |
300 |
|
150 |
450 |
|
109739 |
S |
Butylamine |
5 |
15 |
C |
|
|
|
1189851 |
S |
tert-Butyl chromate; di-tert-butyl |
|
|
|
|
|
|
|
|
|
chromate, as CrO3 |
-- |
0.1 |
C |
|
|
|
|
|
|
as Cr |
|
0.005 |
|
|
|
|
|
|
|
(see also Sections 1532.2, 5206 & 8359) |
|
|
|
|
|
|
2426086 |
|
n-Butyl glycidyl ether; BGE; |
25 |
135 |
|
|
|
|
|
|
|
1-butoxy-2,3-epoxypropane |
|
|
|
|
|
|
138227 |
|
n-Butyl lactate |
5 |
25 |
|
|
|
|
109795 |
|
n-Butyl mercaptan |
0.5 |
1.5 |
|
|
|
|
89725 |
S |
o-sec-Butylphenol |
5 |
30 |
|
|
|
|
98511 |
|
p-tert-Butyltoluene |
1 |
6.1 |
|
20 |
120 |
|
7440439 |
|
Cadmium metal dust, as Cd |
|
|
|
|
|
|
|
|
|
(see also Sections 1532 & 5207) |
-- |
0.005 |
|
|
|
|
|
|
Cadmium, soluble salts, as Cd |
|
|
|
|
|
|
|
|
|
(see also Sections 1532 & 5207) |
-- |
0.005 |
|
|
|
|
1306190 |
|
Cadmium oxide fume, as Cd |
|
|
|
|
|
|
|
|
|
(see also Sections 1532 & 5207 ) |
-- |
0.005 |
|
|
|
|
7778441 |
|
Calcium arsenate; see Arsenic,inorganic (see |
|
|
|
|
|
|
|
|
|
also Section 5214) |
|
|
|
|
|
|
471341 |
|
Calcium carbonate; see Particulates not otherwise regulated |
|
-- |
|
|
|
|
156627 |
|
Calcium cyanamide |
-- |
0.5 |
|
|
|
|
1305620 |
|
Calcium hydroxide |
-- |
5 |
|
|
|
|
1305788 |
|
Calcium oxide |
-- |
2 |
|
|
|
|
|
|
Calcium silicate; see Particulates not otherwise regulated |
|
|
|
|
|
|
1344952 |
|
Calcium silicate (synthetic): see Particulates not otherwise
regulated |
|
|
|
|
|
|
1592230 |
|
Calcium stearate |
-- |
10 |
|
|
|
|
7778189 |
|
Calcium sulfate; see Particulates not otherwise regulated |
|
|
|
|
|
|
76222 |
|
Camphor (synthetic) |
-- |
2 |
|
|
|
|
105602 |
|
Caprolactam dust |
-- |
1 |
|
-- |
3 |
|
105602 |
|
Caprolactam vapor |
5 |
20 |
|
10 |
40 |
|
2425061 |
S |
Captafol |
-- |
0.1 |
|
|
|
|
133062 |
|
Captan |
-- |
5 |
|
|
|
|
63252 |
|
Carbaryl; 1-naphthyl N-methylcarbamate |
-- |
5 |
|
|
|
|
1563662 |
|
Carbofuran |
-- |
0.1 |
|
|
|
|
1333864 |
|
Carbon black |
-- |
3.5 |
|
|
|
|
124389 |
|
Carbon dioxide |
5,000 |
9,000 |
|
30,000 |
54,000 |
|
75150 |
S |
Carbon disulfide |
4 |
12 |
30 ppm |
12 |
36 |
|
630080 |
|
Carbon monoxide |
25 |
29 |
200 ppm |
|
|
|
558134 |
|
Carbon tetrabromide |
0.1 |
1.4 |
|
0.3 |
4 |
|
56235 |
S |
Carbon tetrachloride |
2 |
12.6 |
200 ppm |
10 |
63 |
|
75445 |
|
Carbonyl chloride; see Phosgene |
|
|
|
|
|
|
353504 |
|
Carbonyl fluoride |
2 |
5 |
|
5 |
15 |
|
120809 |
S |
Catechol; pyrocatechol |
5 |
20 |
|
|
|
|
9004346 |
|
Cellulose (paper fiber); see Particulates not otherwise
regulated |
|
|
|
|
|
|
21351791 |
|
Cesium hydroxide |
|
2 |
|
|
|
|
57749 |
S |
Chlordane; 1,2,4,5,6,7,8,8-octachloro-3a,4,7,7a- |
-- |
0.5 |
|
|
|
|
|
|
|
tetrahydro-4,7-methanoindane |
|
|
|
|
|
|
8001352 |
S |
Chlorinated camphene; toxaphene |
-- |
0.5 |
|
-- |
1 |
|
|
|
Chlorinated diphenyl oxide |
-- |
0.5 |
|
|
|
|
7782505 |
|
Chlorine |
0.5 |
1.5 |
|
1 |
3 |
|
10049044 |
|
Chlorine dioxide |
0.1 |
0.3 |
|
0.3 |
0.9 |
|
7790912 |
|
Chlorine trifluoride |
0.1 |
0.4 |
C |
|
|
|
107200 |
|
Chloroacetaldehyde |
1 |
3 |
C |
|
|
|
78955 |
S |
Chloroacetone |
1 |
3.8 |
C |
|
|
|
532274 |
|
alpha-Chloroacetophenone;phenacyl chloride |
0.05 |
0.3 |
|
|
|
|
79049 |
S |
Chloroacetyl chloride |
0.05 |
0.2 |
|
0.15 |
0.69 |
|
108907 |
|
Chlorobenzene; monochlorobenzene |
10 |
46 |
|
|
|
|
2698411 |
S |
o-Chlorobenzylidene malononitrile; OCBM |
0.05 |
0.4 |
C |
|
|
|
74975 |
|
Chlorobromomethane; bromochloromethane |
200 |
1,050 |
|
|
|
|
126998 |
S |
2-Chloro-1,3-butadiene; see Chloroprene |
|
|
|
|
|
|
75456 |
|
Chlorodifluoromethane; Fluorocarbon 22 |
1,000 |
3,500 |
|
|
|
|
53469219 |
S |
Chlorodiphenyl (42% chlorine) |
-- |
1 |
|
|
|
|
11097691 |
S |
Chlorodiphenyl (54% chlorine) |
-- |
0.5 |
|
|
|
|
106898 |
|
1-Chloro-2,3-epoxypropane; see Epichlorohydrin |
|
|
|
|
|
|
75003 |
|
Chloroethane; see Ethyl chloride |
|
|
|
|
|
|
107073 |
|
2-Chloroethanol; see Ethylene chlorohydrin |
|
|
|
|
|
|
75014 |
|
Chloroethylene, see Vinyl chloride, Section 5210 |
|
|
|
|
|
|
67663 |
|
Chloroform; trichloromethane |
2 |
9.78 |
|
|
|
|
74873 |
|
Chloromethane, see Methyl chloride |
|
|
|
|
|
|
107302 |
|
Chloromethyl methyl ether; see Methyl |
|
|
|
|
|
|
|
|
|
chloromethyl ether, Section 5209 |
|
|
|
|
|
|
542881 |
|
bis-Chloromethyl ether, see also Section 5209 |
0.001 |
0.005 |
|
|
|
|
100005 |
|
1-Chloro-4-nitrobenzene; see |
|
|
|
|
|
|
|
|
|
p-Nitrochlorobenzene |
|
|
|
|
|
|
600259 |
|
1-Chloro-1-nitropropane |
2 |
10 |
|
|
|
|
76153 |
|
Chloropentafluoroethane |
1,000 |
6,320 |
|
|
|
|
76062 |
|
Chloropicrin; trichloronitromethane |
0.1 |
0.7 |
|
|
|
|
126998 |
S |
Chloroprene; 2-chloro-1,3-butadiene |
10 |
36 |
|
|
|
|
598787 |
S |
2-Chloropropionic acid |
0.1 |
0.44 |
|
|
|
|
2039874 |
|
o-Chlorostyrene |
50 |
285 |
|
75 |
428 |
|
95498 |
S |
o-Chlorotoluene |
50 |
250 |
|
|
|
|
1929824 |
|
2-Chloro-6-(trichloromethyl)pyridine; see Nitrapyrin |
|
|
|
|
|
|
2921882 |
S |
Chlorpyrifos |
-- |
0.2 |
|
|
|
|
|
|
Chromite ore processing (chromate), as Cr |
-- |
0.005 |
|
|
|
|
|
| (see also Sections 1532.2, 5206 & 8359) |
|
|
|
|
|
|
7440473 |
|
Chromium metal |
-- |
0.5 |
|
|
|
|
|
|
Chromium (II) compounds, as Cr |
-- |
0.5 |
|
|
|
|
|
|
Chromium (III) compounds, as Cr |
-- |
0.5 |
|
|
|
|
|
|
Chromium (VI) compounds, as Cr |
-- |
0.005 |
0.1mg/M3 |
|
|
|
|
| (see also Sections 1532.2, 5206 & 8359) |
|
|
|
|
|
|
14977618 |
|
Chromyl chloride |
0.025 |
0.15 |
|
|
|
|
2971906 |
|
Clopidol |
-- |
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction |
-- |
5 |
|
|
|
|
|
|
Coal (Bituminous) dust |
|
|
|
|
|
|
|
|
|
<5% quartz, respirable fraction(n) |
-- |
2 |
|
|
|
|
|
|
|
>5% quartz, respirable fraction(n) |
-- |
0.1 |
|
|
|
|
|
|
Coal tar pitch volatiles(i) |
-- |
0.2 |
|
|
|
|
7440484 |
|
Cobalt, metal fume and dust, as Co |
-- |
0.020 |
|
|
|
|
|
|
Cobalt carbonyl, as Co |
-- |
0.1 |
|
|
|
|
16842038 |
|
Cobalt hydrocarbonyl, as Co |
-- |
0.1 |
|
|
|
|
|
|
Coke oven emissions, see Section 5211 |
|
0.15 |
|
|
|
|
7440508 |
|
Copper metal fume, as Cu |
-- |
0.1 |
|
|
|
|
|
|
Copper salts, dusts and mists, as Cu |
-- |
1 |
|
|
|
|
|
|
Corundum, see Particulates not otherwise regulated |
|
|
|
|
|
|
|
|
Cotton dust, see also Section 5190 |
-- |
1(j) |
|
|
|
|
1319773 |
S |
Cresol (all isomers) |
5 |
22 |
|
|
|
|
123739 |
S |
Crotonaldehyde; beta-methylacrolein |
|
|
0.3 |
|
|
|
4170303 |
|
|
|
|
|
|
|
|
299865 |
|
Crufomate |
-- |
5 |
|
|
|
|
98828 |
S |
Cumene; isopropylbenzene |
50 |
245 |
|
|
|
|
420042 |
|
Cyanamide |
-- |
2 |
|
|
|
|
|
S |
Cyanide, as CN |
-- |
5 |
|
|
|
|
460195 |
|
Cyanogen |
10 |
20 |
|
|
|
|
506774 |
|
Cyanogen chloride |
0.3 |
0.6 |
C |
|
|
|
110827 |
|
Cyclohexane |
300 |
1,050 |
|
|
|
|
108930 |
S |
Cyclohexanol |
50 |
200 |
|
|
|
|
108941 |
S |
Cyclohexanone |
25 |
100 |
|
|
|
|
110838 |
|
Cyclohexene |
300 |
1,015 |
|
|
|
|
108918 |
S |
Cyclohexylamine |
10 |
40 |
|
|
|
|
121824 |
S |
Cyclonite; RDX; cyclotrimethylenetrinitramine |
-- |
1.5 |
|
|
|
|
542927 |
|
Cyclopentadiene |
75 |
200 |
|
|
|
|
287923 |
|
Cyclopentane |
600 |
1,720 |
|
|
|
|
13121705 |
|
Cyhexatin; tricyclohexyltin hydroxide |
|
5 |
|
|
|
|
94757 |
|
2,4-D;2,4-dichlorophenoxyacetic acid |
-- |
10 |
|
|
|
|
50293 |
S |
DDT; 1,1,1-trichloro-2,2-bis- |
|
|
|
|
|
|
|
|
|
(p-chlorophenyl)ethane |
-- |
1 |
|
|
|
|
62737 |
|
DDVP, see Dichlorvos |
|
|
|
|
|
|
17702419 |
S |
Decaborane |
0.05 |
0.3 |
|
0.15 |
0.9 |
|
8065483 |
S |
Demeton; a mixture of o,o-diethyl |
|
|
|
|
|
|
|
|
|
o-2(ethylthio)ethyl phosphorothloate and |
|
|
|
|
|
|
|
|
|
o,o'-diethyl S-2(ethylthio)ethyl phosphorothioate |
0.01 |
0.1 |
|
|
|
|
123422 |
|
Diacetone alcohol; 4-hydroxy-4-methyl- |
|
|
|
|
|
|
|
|
|
2-pentanone |
50 |
240 |
|
|
|
|
107153 |
|
1,2-Diaminoethane; see Ethylenediamine |
|
|
|
|
|
|
|
|
Diatomacous earth; see Silica-amorphous |
|
|
|
|
|
|
333415 |
S |
Diazinon; o,o-diethyl o-(2-isopropyl-6- |
-- |
0.1 |
|
|
|
|
|
|
|
methyl-4-pyrimidinyl) phosphorothioate |
|
|
|
|
|
|
334883 |
|
Diazomethane |
0.2 |
0.4 |
|
|
|
|
94360 |
|
Dibenzoyl peroxide; see Benzoyl peroxide |
|
|
|
|
|
|
19287457 |
|
Diborane |
0.1 |
0.1 |
|
|
|
|
2528361 |
S |
Dibutyl phenyl phosphate |
0.3 |
3.5 |
|
|
|
|
96128 |
|
1,2-Dibromo-3-chloropropane; DBCP; |
.001 |
.01 |
|
|
|
|
|
|
|
see Section 5212 |
|
|
|
|
|
|
75616 |
|
Dibromodifluoromethane; see |
|
|
|
|
|
|
|
|
|
Difluorodibromomethane |
|
|
|
|
|
|
106934 |
S |
1,2-Dibromomethane; see Ethylene dibromide, |
|
|
|
|
|
|
|
|
|
Section 5219 |
|
|
|
|
|
|
102818 |
S |
2-N-Dibutylaminoethanol |
2 |
14 |
|
|
|
|
107664 |
|
Dibutyl phosphate |
1 |
5 |
|
2 |
10 |
|
84742 |
|
Dibutyl phthalate |
-- |
5 |
|
|
|
|
7572294 |
|
Dichloroacetylene |
0.1 |
0.4 |
C |
|
|
|
95501 |
S |
o-Dichlorobenzene |
25 |
150 |
50 ppm |
|
|
|
106467 |
|
p-Dichlorobenzene; 1,4-dichlorobenzene |
10 |
60 |
200 ppm |
110 |
675 |
|
91941 |
S |
3,3'-Dichlorobenzidine; 4,4'-diamino-3,3'- |
|
|
|
|
|
|
|
|
|
dichlorobiphenyl; see Section 5209 |
|
|
|
|
|
|
764410 |
S |
1,4 -Dichloro-2-butene |
0.005 |
0.025 |
|
|
|
|
75718 |
|
Dichlorodifluoromethane |
1000 |
4950 |
6200 ppm |
|
|
|
118525 |
|
1,3-Dichloro-5,5-dimethyl hydantoin |
-- |
0.2 |
|
-- |
0.4 |
|
75343 |
|
1,1-Dichloroethane |
100 |
400 |
|
|
|
|
107062 |
|
1,2-Dichloroethane, see Ethylene dichloride |
|
|
|
|
|
|
75354 |
|
1,1-Dichloroethylene; see Vinylidene chloride |
|
|
|
|
|
|
540590 |
|
1,2-Dichloroethylene; acetylene dichloride |
200 |
790 |
|
|
|
|
111444 |
S |
Dichloroethyl ether; bis(2-chloroethyl) ether |
5 |
30 |
|
10 |
60 |
|
75434 |
|
Dichlorofluoromethane; Fluorocarbon 21 |
10 |
42 |
|
|
|
|
75092 |
|
Dichloromethane; see Methylene chloride |
|
|
|
|
|
|
594729 |
|
1,1-Dichloro-1-nitroethane |
2 |
10 |
|
|
|
|
78875 |
|
1,2-Dichloropropane; see Propylene dichloride |
|
|
|
|
|
|
542756 |
S |
Dichloropropene |
1 |
5 |
|
|
|
|
75990 |
|
2,2-Dichloropropionic acid |
1 |
6 |
|
|
|
|
76142 |
|
1,2-Dichlorotetrafluoroethane; Fluorocarbon 114 |
1,000 |
7,000 |
|
|
|
|
62737 |
S |
Dichlorvos (DDVP); 2,2-dichlorovinyl |
|
|
|
|
|
|
|
|
|
dimethyl phosphate |
0.1 |
1 |
|
|
|
|
141662 |
S |
Dicrotophos |
-- |
0.25 |
|
|
|
|
5124301 |
|
Dicyclohexylmethane-4,4'-diisocyanate; |
|
|
|
|
|
|
|
|
|
see Methylene bis-(4-cyclohexylisocyanate) |
|
|
|
|
|
|
77736 |
|
Dicyclopentadiene |
5 |
30 |
|
|
|
|
102545 |
|
Dicyclopentadienyl iron |
-- |
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5 |
|
|
|
|
60571 |
S |
Dieldrin; 1,2,3,4,10,10-hexachloro-6,7-epoxy- |
|
|
|
|
|
|
|
|
|
1,4,4a,5,6,7,8,8a-octahydro-1,4-endo-exo-5,8- |
|
|
|
|
|
|
|
|
|
dimethanonaphthalene |
-- |
0.25 |
|
|
|
|
111422 |
S |
Diethanolamine |
0.46 |
2 |
|
|
|
|
109897 |
S |
Diethylamine |
5 |
15 |
C |
|
|
|
112367 |
S |
Diethylene glycol diethyl ether, |
|
|
|
|
|
|
|
|
|
Ethyl diglyme |
5 |
33 |
|
|
|
|
111966 |
S |
Diethylene glycol dimethyl ether, Diglyme |
1 |
5.5 |
|
5 |
27 |
|
100378 |
S |
2-(Diethylamino) ethanol |
2 |
9.6 |
|
|
|
|
123911 |
|
1,4-Diethylene dioxide; see p-Dioxane |
|
|
|
|
|
|
111400 |
S |
Diethylenetriamine |
1 |
4 |
|
|
|
|
60297 |
|
Diethyl ether; see Ethyl ether |
|
|
|
|
|
|
298044 |
|
Di-(2-ethylhexyl) phthalate; |
|
|
|
|
|
|
|
|
|
see Di-sec-octyl phthalate |
|
|
|
|
|
|
96220 |
|
Diethyl ketone |
200 |
705 |
|
300 |
1057 |
|
84662 |
|
Diethyl phthalate |
-- |
5 |
|
|
|
|
75616 |
|
Difluorodibromomethane; dibromodifluoromethane |
100 |
860 |
|
|
|
|
2238075 |
|
Diglycidyl ether; DGE; bis(2,3-epoxypropyl) |
|
|
|
|
|
|
|
|
|
ether |
0.1 |
0.5 |
|
|
|
|
123319 |
|
p-Dihydroxybenzene; see Hydroquinone |
|
|
|
|
|
|
108838 |
|
Diisobutyl ketone; 2,6-dimethyl-4-heptanone |
25 |
150 |
|
|
|
|
108189 |
S |
Diisopropylamine |
5 |
20 |
|
|
|
|
108203 |
|
Diisopropyl ether; see Isopryl ether |
|
|
|
|
|
|
109875 |
|
Dimethoxymethane; see Methylal |
|
|
|
|
|
|
127195 |
S |
Dimethylacetamide |
10 |
35 |
|
|
|
|
124403 |
|
Dimethylamine |
5 |
9.2 |
|
15 |
27.6 |
|
60117 |
|
4-Dimethylaminoazobenzene, see Section 5209 |
|
|
|
|
|
|
1300738 |
|
Dimethylaminobenzene; see Xylidene |
|
|
|
|
|
|
121697 |
S |
N,N-Dimethylaniline; dimethylphenylamine |
5 |
25 |
|
10 |
50 |
|
1330207 |
|
Dimethylbenzene; see Xylene |
|
|
|
|
|
|
108849 |
|
1,3-Dimethylbutyl acetate; see sec- |
|
|
|
|
|
|
|
|
|
Hexyl acetate |
|
|
|
|
|
|
300765 |
|
o,o-Dimethyl o-(1,2-dibromo-2,2-dichloroethyl) |
|
|
|
|
|
|
|
|
|
phosphate; see Naled |
|
|
|
|
|
|
14857342 |
|
Dimethylethoxysilane |
0.5 |
2.1 |
|
1.5 |
6.4 |
|
68122 |
S |
Dimethylformamide; DMF |
10 |
30 |
|
|
|
|
108838 |
|
2,6-Dimethyl-4-heptanone; see |
|
|
|
|
|
|
|
|
|
Diisobutyl ketone |
|
|
|
|
|
|
57147 |
S |
1,1-Dimethylhydrazine |
0.01 |
0.025 |
|
|
|
|
67641 |
|
Dimethyl ketone; see Acetone |
|
|
|
|
|
|
62759 |
|
N,N-Dimethylnitrosamine; see |
|
|
|
|
|
|
|
|
|
N-Nitrosodimethylamine, Section 5209 |
|
|
|
|
|
|
131113 |
|
Dimethyl phthalate |
-- |
5 |
|
|
|
|
77781 |
S |
Dimethyl sulfate; methyl sulfate |
0.1 |
0.5 |
|
|
|
|
148016 |
|
Dinitolmide; 3,5-Dinitro-o-toluamide |
-- |
5 |
|
|
|
|
528290, |
S |
Dinitrobenzene (all (isomers) |
|
|
|
|
|
|
99650, |
|
|
ortho, meta and |
|
|
|
|
|
|
100254 |
|
|
para isomers |
0.15 |
1 |
|
|
|
|
534521 |
S |
4,6-Dinitro-o-cresol; 2-methyl- |
|
|
|
|
|
|
|
|
|
4,6-dinitrophenol |
-- |
0.2 |
|
|
|
|
25321146 |
S |
2,4-Dinitrotoluene |
-- |
0.15 |
|
|
|
|
123911 |
S |
p-Dioxane, tech. grade; |
|
|
|
|
|
|
|
|
|
1,4-dioxacyclohexane; |
25 |
90 |
|
|
|
|
|
|
|
1,4-diethylene dioxide |
|
|
|
|
|
|
78342 |
S |
Dioxathion |
-- |
0.2 |
|
|
|
|
92524 |
|
Diphenyl; see Biphenyl |
|
|
|
|
|
|
122394 |
|
Diphenylamine; N-phenylaniline |
-- |
10 |
|
|
|
|
101688 |
|
Diphenylmethane diisocyanate; see |
|
|
|
|
|
|
|
|
Methylene bis(phenylisocyanate) |
|
|
|
|
|
|
123193 |
|
Dipropyl ketone |
50 |
235 |
|
|
|
|
34590948 |
S |
Dipropylene glycol methyl ether |
100 |
600 |
|
150 |
900 |
|
85007 |
|
Diquat; 1,1'-ethylene-2,2'- |
|
|
|
|
|
|
|
|
|
dipyridinium dibromide |
-- |
|
|
|
|
|
|
|
|
Total dust |
-- |
0.5 |
|
|
|
|
|
|
|
Respirable fraction(n) |
|
|
|
|
|
|
117817 |
|
Di-sec-octyl phthalate; bis(2 ethylhexyl) phthalate |
-- |
5 |
|
-- |
|
|
97778 |
|
Disulfiram |
-- |
2 |
|
|
|
|
298044 |
S |
Disulfoton; o,o-diethyl |
|
|
|
|
|
|
|
|
|
S-2-(ethylthio)ethyl phosphorodithioate |
-- |
0.1 |
|
|
|
|
128370 |
|
2,6-Di-tert-butyl-p-cresol |
-- |
10 |
|
|
|
|
330541 |
|
Diuron |
-- |
10 |
|
|
|
|
68122 |
|
DMF; see Dimethylformamide |
|
|
|
|
|
|
57147 |
|
DMH; see 1,1-Dimethylhydrazine |
|
|
|
|
|
|
1321740 |
|
Divinyl benzene |
10 |
50 |
|
|
|
|
|
|
Dust, nuisance dust and particulates, |
|
|
|
|
|
|
|
|
|
see Particulates not otherwise regulated |
|
|
|
|
|
|
12415348 |
|
Emery; see Particulates not otherwise regulated |
|
|
|
|
|
|
115297 |
S |
Endosulfan; 6,7,8,9,10,10-hexachloro- |
|
|
|
|
|
|
|
|
|
1,5,5a,6,9,9a-hexahydro-6,9-methano-2,4, |
|
|
|
|
|
|
|
|
|
3-benzodioxathiepin-3-oxide |
-- |
0.1 |
|
|
|
|
72208 |
S |
Endrin; 1,2,3,4,10,10-hexachloro-6,7-epoxy- |
|
|
|
|
|
|
|
|
|
1,4,4a,5,6,7,8,8a-octahydro-1,4-endo-endo-5, |
|
|
|
|
|
|
|
|
|
8-dimethanonaphthalene |
-- |
0.1 |
|
|
|
|
13838169 |
|
Enflurane |
2 |
15 |
|
|
|
|
106898 |
S |
Epichlorohydrin; 1-chloro-2, |
|
|
|
|
|
|
|
|
|
3-epoxypropane |
0.05 |
0.19 |
|
|
|
|
2104645 |
S |
EPN; o-ethyl o-(p-nitrophenyl) |
|
|
|
|
|
|
|
|
|
phenylphosphonothioate |
-- |
0.1 |
|
|
|
|
75569 |
|
1,2-Epoxypropane; see Propylene oxide |
|
|
|
|
|
|
556525 |
|
2,3-Epoxypropanol; see Glycidol |
|
|
|
|
|
|
74840 |
|
Ethane |
(h) |
-- |
|
|
|
|
75081 |
|
Ethanethiol; see Ethyl mercaptan |
|
|
|
|
|
|
64175 |
|
Ethanol; see Ethyl alcohol |
|
|
|
|
|
|
141435 |
|
Ethanolamine; 2-aminoethanol |
3 |
8 |
|
6 |
15 |
|
563122 |
S |
Ethion |
-- |
0.4 |
|
|
|
|
110805 |
S |
2-Ethoxyethanol |
5 |
18 |
|
|
|
|
111159 |
S |
2-Ethoxyethyl acetate |
5 |
27 |
|
|
|
|
141786 |
|
Ethyl acetate |
400 |
1,400 |
|
|
|
|
140885 |
S |
Ethyl acrylate |
5 |
20 |
|
25 |
100 |
|
64175 |
|
Ethyl alcohol; ethanol |
1,000 |
1,900 |
|
|
|
|
75047 |
S |
Ethylamine |
5 |
9.2 |
C |
|
|
|
541855 |
|
Ethyl sec-amyl ketone; 5-methyl-3-heptanone |
25 |
130 |
|
|
|
|
100414 |
|
Ethylbenzene |
100 |
435 |
|
125 |
545 |
|
74964 |
S |
Ethyl bromide |
5 |
22 |
|
|
|
|
106354 |
|
Ethyl butyl ketone; 3-heptanone |
50 |
230 |
|
75 |
345 |
|
75003 |
S |
Ethyl chloride; chloroethane |
100 |
264 |
|
|
|
|
7085850 |
|
Ethyl cyanoacrylate |
0.2 |
1.02 |
|
|
|
|
673923 |
|
Ethyl tert-butyl ether |
5 |
21 |
|
|
|
|
74851 |
|
Ethylene |
(h) |
-- |
|
|
|
|
107073 |
S |
Ethylene chlorohydrin; 2-chloroethanol |
1 |
3 |
C |
|
|
|
107153 |
|
Ethylenediamine; 1,2-diaminoethane |
10 |
25 |
|
|
|
|
106934 |
S |
Ethylene dibromide; 1,2-dibromoethane, |
|
|
|
|
|
|
|
|
|
see Section 5219 |
0.13 |
1 |
C |
|
|
|
107062 |
|
Ethylene dichloride; 1,2-dichloroethane |
1 |
4 |
200 ppm |
2 |
8 |
|
107211 |
|
Ethylene glycol (vapor) |
40 |
100 |
C |
|
|
|
629141 |
S |
Ethylene glycol diethyl ether, 1,2-diethoxyethane |
5 |
24 |
|
|
|
|
110714 |
S |
Ethylene glycol dimethyl ether, |
1 |
3.7 |
|
5 |
18 |
|
|
|
|
1,2-dimethoxyethane, Glyme |
|
|
|
|
|
|
628966 |
S |
Ethylene glycol dinitrate |
|
(k) |
|
-- |
0.1 |
|
110805 |
S |
Ethylene glycol monoethyl ether, see |
|
|
|
|
|
|
|
|
|
2-Ethoxyethanol |
|
|
|
|
|
|
109864 |
S |
Ethylene glycol monomethyl ether, see |
|
|
|
|
|
|
|
|
|
2-Methoxyethanol |
|
|
|
|
|
|
110496 |
S |
Ethylene glycol monomethyl ether acetate; |
|
|
|
|
|
|
|
|
|
see 2-Methoxyethyl acetate |
|
|
|
|
|
|
151564 |
S |
Ethyleneimine; see also Section 5209 |
0.5 |
1 |
|
|
|
|
75218 |
|
Ethylene oxide; see Section 5220 |
1 |
2 |
|
5 |
|
|
60297 |
|
Ethyl ether |
400 |
1,200 |
|
500 |
1500 |
|
109944 |
|
Ethyl formate |
100 |
300 |
|
|
|
|
75343 |
|
Ethylidene chloride; see 1,1-Dichloroethane |
|
|
|
|
|
|
16219753 |
|
Ethylidene norbornene |
5 |
25 |
C |
|
|
|
75081 |
|
Ethyl mercaptan; ethanethiol |
0.5 |
1 |
|
|
|
|
78933 |
|
Ethyl methyl ketone; see Methyl ethyl ketone |
|
|
|
|
|
|
100743 |
S |
N-Ethylmorpholine; 4-ethyl-1, |
|
|
|
|
|
|
|
|
|
4-tetrahydrooxazine |
5 |
23 |
|
|
|
|
78104 |
|
Ethyl silicate; tetraethyl silicate |
10 |
85 |
|
|
|
|
22224926 |
S |
Fenamiphos |
|
0.1 |
|
|
|
|
115902 |
|
Fensulfothion |
-- |
0.1 |
|
|
|
|
55389 |
S |
Fenthion |
-- |
0.2 |
|
|
|
|
14484641 |
|
Ferbam; ferric N,N-dimethylthiocarbamate |
-- |
10 |
|
|
|
|
12604589 |
|
Ferrovanadium dust |
-- |
1 |
|
-- |
3 |
|
14808607 |
|
Fibrous glass, see Glass |
|
|
|
|
|
|
|
|
Flour dust |
|
0.5(s) |
|
|
|
|
|
|
Fluorides, as F |
-- |
2.5 |
|
|
|
|
7782414 |
|
Fluorine |
0.1 |
0.2 |
|
|
|
|
75694 |
|
Fluorocarbon 11; see Trichlorofluoromethane |
|
|
|
|
|
|
75718 |
|
Fluorocarbon 12; see Dichlorodifluoromethane |
|
|
|
|
|
|
75434 |
|
Fluorocarbon 21; see Dichlorofluoromethane |
|
|
|
|
|
|
75456 |
|
Fluorocarbon 22; see Chlorodifluoromethane |
|
|
|
|
|
|
76120 |
|
Fluorocarbon 112; see 1,1,2,2-Tetrachloro- |
|
|
|
|
|
|
|
|
|
1,2-difluoroethane |
|
|
|
|
|
|
76131 |
|
Fluorocarbon 113; see 1,1,2-Trichloro-1,2,2- |
|
|
|
|
|
|
|
|
|
trifluoroethane |
|
|
|
|
|
|
|
|
Fluorocarbon 114; see 1,2- |
|
|
|
|
|
|
|
|
|
Dichlorotetrafluoroethane |
|
|
|
|
|
|
75694 |
|
Fluorotrichloromethane; see |
|
|
|
|
|
|
|
|
|
Trichlorofluoromethane |
|
|
|
|
|
|
944229 |
S |
Fonofos |
-- |
0.1 |
|
|
|
|
50000 |
|
Formaldehyde, see Section 5217 |
0.75 |
-- |
|
2 |
-- |
|
75127 |
S |
Formamide |
10 |
18 |
|
|
|
|
64186 |
|
Formic acid |
5 |
9 |
|
10 |
19 |
|
98011 |
S |
Furfural |
2 |
8 |
|
|
|
|
98000 |
S |
Furfuryl alcohol |
10 |
40 |
|
15 |
60 |
|
8006619 |
|
Gasoline |
300 |
900 |
|
500 |
1500 |
|
7782652 |
|
Germanium tetrahydride |
0.2 |
0.6 |
|
|
|
|
|
|
Glass, fibrous |
1.0 f/cc(q) |
|
|
|
|
|
111308 |
|
Glutaraldehyde (t) |
0.05 |
0.2 |
C(u) |
|
|
|
56815 |
|
Glycerin mist; see Particulates not otherwise regulated |
|
|
|
|
|
|
123944 |
|
Glyceryl stearate |
-- |
10 |
|
|
|
|
556525 |
|
Glycidol; 2,3-epoxy-1-propanol |
2 |
6.1 |
|
|
|
|
111762 |
|
Glycol monobutyl ether; see 2-Butoxyethanol |
|
|
|
|
|
|
110805 |
|
Glycol monoethyl ether; see 2-Ethoxyethanol |
|
|
|
|
|
|
109864 |
|
Glycol monoethyl ether; see 2-Methoxyethanol |
|
|
|
|
|
|
|
|
Grain dust (oat, wheat, barley) |
-- |
10 |
|
|
|
|
7782425 |
|
Graphite, natural respirable dust |
|
2.5 |
|
|
|
|
|
|
Graphite, synthetic |
|
|
|
|
|
|
|
|
|
Total dust |
-- |
10 |
|
|
|
|
|
|
|
Respirable fraction(n) |
-- |
5 |
|
|
|
|
13397245 |
|
Gypsum; Calcium sulfate dihydrate; see |
|
|
|
|
|
|
|
|
|
Particulates not otherwise regulated |
|
|
|
|
|
|
7440586 |
|
Hafnium |
-- |
0.5 |
|
|
|
|
151677 |
|
Halothane |
2 |
16 |
|
|
|
|
822060 |
|
HDI; see Hexamethylene diisocyanate |
|
|
|
|
|
|
7440597 |
|
Helium |
(h) |
-- |
|
|
|
|
76448 |
S |
Heptachlor; 1,4,5,6,7,8,8-hepta-chloro- |
|
|
|
|
|
|
|
|
|
3a,4,7,7a-tetrahydro-4,7-methanoindene |
-- |
0.05 |
|
|
|
|
142825 |
|
n-Heptane |
400 |
1,600 |
|
500 |
2000 |
|
118741 |
S |
Hexachlorobenzene |
-- |
0.002 |
|
|
|
|
87683 |
S |
Hexachlorobutadiene |
0.02 |
0.24 |
|
|
|
|
77474 |
|
Hexachlorocyclopentadiene |
0.01 |
0.11 |
|
|
|
|
67721 |
S |
Hexachloroethane; perchloroethane |
1 |
10 |
|
|
|
|
1335871 |
S |
Hexachloronaphthalene |
-- |
0.2 |
|
|
|
|
684162 |
S |
Hexafluoroacetone; 1,1,1,3,3,3-hexafluoro- |
|
|
|
|
|
|
|
|
|
2-propanone |
0.1 |
0.7 |
|
|
|
|
822060 |
|
Hexamethylene diisocyanate; HDI |
0.005 |
0.034 |
|
|
|
|
110543 |
S |
n-Hexane |
50 |
180 |
|
|
|
|
|
|
|
Hexane, other isomers |
500 |
1800 |
|
1000 |
3600 |
|
124094 |
|
1,6-Hexanediamine |
0.5 |
2.3 |
|
|
|
|
591786 |
|
2-Hexanone; see Methyl butyl ketone |
|
|
|
|
|
|
592416 |
|
1-Hexene |
50 |
180 |
|
|
|
|
108101 |
|
Hexone; see Methyl isobutyl ketone |
|
|
|
|
|
|
108849 |
|
sec-Hexyl acetate; 4-methyl-2-pentyl acetate; |
|
|
|
|
|
|
|
|
|
1,3-dimethyl-butyl acetate |
50 |
300 |
|
|
|
|
107415 |
|
Hexylene glycol |
25 |
125 |
C |
|
|
|
302012 |
S |
Hydrazine |
0.01 |
0.013 |
|
|
|
|
10035106 |
|
Hydrobromic acid; see Hydrogen bromide |
|
|
|
|
|
|
7647010 |
|
Hydrochloric acid; see Hydrogen chloride |
|
|
|
|
|
|
74908 |
|
Hydrocyanic acid; see Hydrogen cyanide |
|
|
|
|
|
|
7664393 |
|
Hydrofluoric acid; see Hydrogen fluoride |
|
|
|
|
|
|
1333740 |
|
Hydrogen |
(h) |
-- |
|
|
|
|
61788327 |
|
Hydrogenated terphenyls |
0.5 |
5 |
|
|
|
|
10035106 |
|
Hydrogen bromide |
3 |
10 |
C |
|
|
|
7647010 |
|
Hydrogen chloride; muriatic acid |
5 |
7 |
C |
|
|
|
74908 |
S |
Hydrogen cyanide |
4.7 |
5 |
C |
|
|
|
7664393 |
|
Hydrogen fluoride, as F |
3 |
2.5 |
|
6 |
-- |
|
7722841 |
|
Hydrogen peroxide, as H2O2 |
1 |
1.4 |
|
|
|
|
7783075 |
|
Hydrogen selenide, as Se |
0.05 |
0.2 |
|
|
|
|
7783064 |
|
Hydrogen sulfide |
10 |
14 |
50 ppm |
15 |
21 |
|
123319 |
|
Hydroquinone; 1,4-benezendiol |
-- |
2 |
|
|
|
|
999611 |
S |
2-Hydroxypropyl acrylate |
0.5 |
3 |
|
|
|
|
95136 |
|
Indene |
10 |
48 |
|
|
|
|
7440746 |
|
Indium |
-- |
0.1 |
|
|
|
|
|
|
Indium compounds |
-- |
0.1 |
|
|
|
|
7553562 |
|
Iodine |
0.1 |
1 |
C |
|
|
|
75478 |
|
Iodoform |
0.6 |
10 |
|
|
|
|
4098719 |
|
IPDI; see Isophorone diisocyanate |
|
|
|
|
|
|
1309371 |
|
Iron oxide fume |
-- |
5 |
|
|
|
|
13463406 |
|
Iron pentacarbonyl, as Fe |
0.1 |
0.8 |
|
0.2 |
1.6 |
|
|
|
Iron salts, soluble, as Fe |
-- |
1 |
|
|
|
|
123922 |
|
Isoamyl acetate; 3-methylbutyl acetate; see Pentyl acetate |
|
|
|
|
|
|
123513 |
|
Isoamyl alcohol; 3-methylbutanol |
100 |
360 |
|
125 |
450 |
|
110190 |
|
Isobutyl acetate; 2-methylpropyl acetate |
150 |
700 |
|
|
|
|
78831 |
|
Isobutyl alcohol; 2-methylpropanol |
50 |
150 |
|
|
|
|
26675467 |
|
Isoflurane |
2 |
15 |
|
|
|
|
26952216 |
S |
Isooctyl alcohol |
50 |
270 |
|
|
|
|
78591 |
|
Isophorone; 3,5,5-trimethyl-2-cyclohexene- |
|
|
|
|
|
|
|
|
|
1-one |
4 |
23 |
|
|
|
|
4098719 |
S |
Isophorone diisocyanate; IPDI |
0.005 |
0.045 |
|
0.02 |
-- |
|
109591 |
|
Isopropoxyethanol |
25 |
105 |
|
|
|
|
108214 |
|
Isopropyl acetate |
250 |
950 |
|
310 |
1185 |
|
67630 |
|
Isopropyl alcohol |
400 |
980 |
|
500 |
1225 |
|
75310 |
|
Isopropylamine |
5 |
12 |
|
10 |
24 |
|
768525 |
S |
N-isopropylaniline |
2 |
10 |
|
|
|
|
108203 |
|
Isopropyl ether; diisopropyl ether |
250 |
1,050 |
|
|
|
|
4016142 |
|
Isopropyl glycidyl ether; IGE; |
|
|
|
|
|
|
|
|
|
1,2-epoxy-3-isopropoxypropane |
50 |
240 |
|
75 |
360 |
|
1332587 |
|
Kaolin; (respirable dust containing no |
|
|
|
|
|
|
|
|
|
asbestos and <1% crystaline silica) |
-- |
2 |
|
|
|
|
463514 |
|
Ketene; ethenone |
0.5 |
0.9 |
|
1.5 |
3 |
|
|
|
Lead arsenate, see Sections 5214 and 5198 |
|
|
|
|
|
|
7758976 |
|
Lead chromate, as Pb |
-- |
0.02 |
|
|
|
|
|
|
|
as Cr |
-- |
0.005 |
|
|
|
|
|
|
|
(see also Section 5198, 1532.1, 1532.2, 5206 & 8359) |
|
|
|
|
|
|
|
|
Lead (metallic) and inorganic compounds, dust |
|
|
|
|
|
|
|
|
|
and fume, as Pb (see also Section 5198 ) |
-- |
0.05 |
|
|
|
|
78002 |
|
Lead tetraethyl, see Tetraethyl lead |
|
|
|
|
|
|
75741 |
|
Lead tetramethyl, see Tetramethyl lead |
|
|
|
|
|
|
1317653 |
|
Limestone; calcium carbonate; see |
|
|
|
|
|
|
|
|
|
Particulates not otherwise regulated |
|
|
|
|
|
|
58899 |
S |
Lindane; 1,2,3,4,5,6-hexachlorocyclohexane, |
|
|
|
|
|
|
|
|
|
gamma isomer |
-- |
0.5 |
|
|
|
|
7580678 |
|
Lithium hydride |
-- |
0.025 |
|
|
|
|
|
|
L.P.G.; liquefied petroleum gas |
1,000 |
1,800 |
|
|
|
|
4485125 |
|
Lithium stearate |
-- |
10 |
|
|
|
|
13717005 |
|
Magnesite; magnesium carbonate; see |
|
|
|
|
|
|
|
|
|
Particulates not otherwise regulated |
|
|
|
|
|
|
1309484 |
|
Magnesium oxide fume, as Mg |
-- |
10 |
|
|
|
|
557040 |
|
Magnesium stearate |
-- |
10 |
|
|
|
|
121755 |
S |
Malathion; o,o-dimethyl S-1(1,2- |
|
|
|
|
|
|
|
|
|
dicarboethyoxyethyl) phosphorodithioate |
-- |
10 |
|
|
|
|
108316 |
|
Maleic anhydride; cis-butenedioic anhydride |
0.1 |
0.4 |
|
|
|
|
|
|
Manganese and compounds, as Mn |
-- |
0.2 |
|
|
|
|
7439965 |
|
Manganese fume, as Mn |
-- |
0.2 |
|
-- |
3 |
|
12079651 |
S |
Manganese, cyclopentadienyl-tricarbonyl, |
|
|
|
|
|
|
|
|
|
as Mn |
-- |
0.1 |
|
|
|
|
|
|
Manganese tetroxide |
-- |
0.2 |
|
|
|
|
|
|
Marble; calcium carbonate; see |
|
|
|
|
|
|
|
|
|
Particulates not otherwise regulated |
|
|
|
|
|
|
101779 |
S |
MDA; see 4,4'-Methylene dianiline |
|
|
|
|
|
|
101688 |
|
MDI; see Methylene bis(phenylisocyanate) |
|
|
|
|
|
|
7439976 |
S |
Mercury alkyls, as Hg |
-- |
0.01 |
0.04 mg/M3 |
-- |
0.03 |
|
7439976 |
S |
Mercury, metallic and inorganic compounds as Hg |
-- |
0.025 |
0.1 mg/M3 |
|
|
|
7439976 |
S |
Mercury aryl compounds as Hg |
-- |
0.01 |
C |
|
|
|
108678 |
|
Mesitylene; see 1,3,5-Trimethylbenzene |
|
|
|
|
|
|
141797 |
|
Mesityl oxide; 4-methyl-3-pentene-2-one |
15 |
60 |
|
25 |
100 |
|
79414 |
S |
Methacrylic acid |
20 |
70 |
|
|
|
|
74828 |
|
Methane |
(h) |
-- |
|
|
|
|
74931 |
|
Methanethiol; see Methyl mercaptan |
|
|
|
|
|
|
67561 |
|
Methanol; see Methyl alcohol |
|
|
|
|
|
|
16752775 |
S |
Methomyl |
-- |
2.5 |
|
|
|
|
72435 |
|
Methoxychlor; 1,1,1-trichloro-2, |
|
|
|
|
|
|
|
|
|
2-bis(p-methoxyphenyl)ethane |
-- |
10 |
|
|
|
|
109864 |
S |
2-Methoxyethanol |
5 |
16 |
|
|
|
|
110496 |
|
2-Methoxyethyl acetate |
5 |
24 |
|
|
|
|
76380 |
|
Methoxyflurane |
2 |
13 |
|
|
|
|
150765 |
|
4-Methoxyphenol |
-- |
5 |
|
|
|
|
79209 |
|
Methyl acetate |
200 |
610 |
|
250 |
760 |
|
74997 |
|
Methyl acetylene; propyne |
1,000 |
1,650 |
|
|
|
|
|
|
Methyl acetylene-propadiene mixture; MAPP |
1,000 |
1,800 |
|
1250 |
2250 |
|
96333 |
S |
Methyl acrylate |
10 |
35 |
|
|
|
|
126987 |
S |
alpha-Methylacrylonitrile |
1 |
3 |
|
|
|
|
624419 |
|
2-Methylbutyl acetate; see Pentyl acetate |
|
|
|
|
|
|
109875 |
|
Methylal; dimethoxymethane |
1,000 |
3,100 |
|
|
|
|
67561 |
S |
Methyl alcohol; methanol |
200 |
260 |
1000 ppm |
250 |
325 |
|
74895 |
|
Methylamine |
5 |
6.4 |
|
15 |
19 |
|
108112 |
|
Methyl amyl alcohol; see Methyl |
|
|
|
|
|
|
|
|
|
isobutyl carbinol |
|
|
|
|
|
|
110430 |
|
Methyl n-amyl ketone; 2-heptanone |
50 |
235 |
|
|
|
|
100618 |
S |
N-Methylaniline; monomethylaniline |
0.5 |
2 |
|
|
|
|
95534 |
|
o-Methylaniline; see o-Toluidine |
|
|
|
|
|
|
74839 |
S |
Methyl bromide |
1 |
3.88 |
20 ppm |
|
|
|
591786 |
S |
Methyl butyl ketone; 2-hexanone |
5 |
20 |
|
|
|
|
74873 |
|
Methyl chloride |
50 |
105 |
300 ppm |
100 |
210 |
|
71556 |
|
Methyl chloroform; 1,1,1-trichloroethane |
350 |
1900 |
800 ppm |
450 |
2450 |
|
107302 |
|
Methyl chloromethyl ether; see Section 5209 |
|
|
|
|
|
|
75058 |
|
Methyl cyanide; see Acetonitrile |
|
|
|
|
|
|
137053 |
|
Methyl 2-cyanoacrylate |
0.2 |
0.908 |
|
4 |
|
|
108872 |
|
Methylcyclohexane |
400 |
1,600 |
|
|
|
|
25639423 |
|
Methylcyclohexanol (meta- and |
|
|
|
|
|
|
|
|
|
para-isomer mixture) |
50 |
235 |
|
|
|
|
583608 |
S |
o-Methylcyclohexanone |
50 |
230 |