This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at https://www.dir.ca.gov/od_pub/disclaimer.html.
 
Subchapter 7. General Industry Safety Orders
Group 10. Gas Systems for Welding and Cutting
Article 82. Stationary Automatic Acetylene Generators
Return to index
New query

§4810. Drain Connection.


Unless otherwise specifically approved, generators shall not be fitted with continuous drain connections leading to sewers but shall discharge through an open connection into a suitably vented outdoor receptacle or residue pit which may have such connections.

NOTE: An open connection for the sludge drawoff is desirable to enable the generator operator to observe leakage of generating water from the drain valve or sludge cock.

NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.