| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
(a) Car frames and platforms shall be constructed of metal or a combination of metal and wood having a factor of safety of not less than 5 based on rated load.
(b) Cast iron shall not be used in any member of the car frame or platform other than for guides or guide shoe brackets.
(Title 24, Part 7, Section 7-3093.8)
NOTE: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.