| This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html. |
| Return to index New query |
The top car clearance shall be not less than 6 in. (152 mm) plus 1 in. (25 mm) for each 3 1/3 fpm (0.017 m/s) of the rated speed in excess of 30 fpm (0.15 m/s).
(Title 24, Part 7, Section 7-3093.3)
NOTE
Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
HISTORY
1. New section filed 7-22-86; effective thirtieth day thereafter (Register 86, No. 36).
2. Editorial correction (Register 97, No. 6).
3. Amendment of section heading filed 8-29-2001; operative 9-28-2001 (Register 2001, No. 35).
Go Back to Article 15 Table of Contents