§3093.16. Operation of Safeties.

The car safety shall be of the inertia or other approved type operated by the breakage of the suspension means or by the action of a speed governor. If it is a speed governor type, the governor shall operate the safety at a maximum speed of 75 fpm (0.38 m/s). On the breakage of the suspension means, the safety shall operate without delay and independent of the speed governor action.

(Title 24, Part 7, Section 7-3093.16)


Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.