Regulations concerning ramps and runways are as follows:

A. General requirements

  1. Ramps must be properly designed to provide a safe means of access for foot or vehicle traffic. 1623, 1624, 1625
  2. Open sides of ramps that are 7 1/2 ft. or more above ground must have standard guardrails. 1621(a)

B. Foot ramps

  1. Foot ramps must be at least 20 in. wide and must be secured and supported to avoid deflection or springing action. 1624(a)
  2. If the ramp slope exceeds 2 ft. of rise for every 10 ft. of run, cleats must be 8 in. or more in length and must be placed not more than 16 in. apart. 1624

C. Wheelbarrow ramps and runways

  1. Wheelbarrow ramps and runways must be firmly secured against displacement. 1624(c)
  2. Ramps more than 3 ft. high must be 30 in. wide, and planks must be firmly cleated together. 1623
  3. Falsework design loads must be increased by 10 psf for worker-propelled carts. 1717(a)