This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html.


Subchapter 13. Logging and Sawmill Safety Orders
Article 17. Lath, Shingle, and Shake Mills

Return to index
New query
§6402. Bolters and Lath Machines, Appendix A



Whistle-Signals

The following standard signals shall be adopted and used for the type of operation listed. If a standard signal is not listed to cover an unusual or new situation, a new signal may be adopted and used for that specific situation.

HIGH-LEAD LOGGING WHISTLE SIGNALS

 
1 short...........................  Stop all lines                             
3 short -3 short..................  Ahead slow on mainline                     
3 short...........................  Ahead on mainline                          
2 short...........................  Ahead on haulback                          
2 short -2 short..................  Ahead slow on haulback                     
3 short -1 short..................  Ahead on strawline                         
3 short -1 short -3 short.........  Ahead slow on strawline                    
4 short...........................  Slack mainline                             
2 short -4 short..................  Slack haulback                             
3 short -1 short -4 short.........  Slack strawline                            
3 short -2 short..................  Tight line                                 
3 short...........................  When rigging is in:strawline               
                                    back on haulback                           
3 short plus "X" number of          When rigging is in: Indicates              
  shorts..........................                                             
                                    number of sections of                      
                                    strawline back on rigging                  
3 short -1 short -2 short.........  Strawline back on rigging                  
1 short...........................  When rigging is in: Chaser inspect         
                                    and repair rigging                         
2 short...........................  When rigging is in: No chokers back        
2 short -1 short plus "X" number    Number chokers back                        
  of shorts.......................                                             
2 short -4 short..................  When rigging in: Slack haulback -          
                                    hold all lines until 2 short blown         
3 medium..........................  Hooker                                     
3 medium -4 short.................  Hooker and his crew                        
5 long............................  Climber                                    
4 long............................  Foreman                                    
1 long -1 short...................  Start or stop work                         
7 long -2 short...................  Man injured, call transportation and       
                                      stretcher                                
1 long -1 short repeated..........  Fire                                       
 
 
GRABINSKI SYSTEM

 
2 short -1 short....  Slack mainline and haulback together
2 long..............  Take off or put on rider block      
 
 
SLACK LINE WHISTLE SIGNALS

 
2 short -2 short -2 short........  First cable up when road has been           
                                   changed and tail hold made fast             
2 short -2 short -2 short........  Drop skyline                                
1 short..........................  Stop any moving line                        
1 long...........................  When logging, slack skyline                 
2 short..........................  Ahead on skyline                            
1 long -2 short..................  Ahead easy on skyline                       
3 short..........................  Ahead on skidding line,                     
                                   holding haulback                            
3 short -3 short.................  Ahead easy on skidding line                 
                                   with slack haulback                         
4 short..........................  Slack skidding line                         
2 short -2 short -repeated         Ahead easy on haulback with                 
  once...........................                                              
                                   slack skidding line                         
2 short -2 short.................  Ahead on haulback                           
2 short -2 short -4 short........  Slack haulback                              
2 short -pause -3 short..........  Pick up skyline and skid                    
2 short -pause -2 short -2         Pick up skyline and skid                    
  short..........................                                              
3 short -1 short.................  When carriage is in: strawline              
                                   back on haulback                            
3 short -1 short -2 short........  When carriage is in: strawline              
                                   back on carriage                            
3 short -1 short.................  When strawline is out: ahead on strawline   
3 short -2 short.................  Tight line                                  
3 short -1 short -4 short........  Slack strawline                             
3 short -1 short -3 short........  Pull easy on strawline                      
2 long...........................  Ahead on transfer                           
2 long -4 short..................  Slack transfer                              
2 long -2 short -2 short.........  When carriage is in: transfer               
                                   back on carriage                            
1 long -1 short..................  When carriage is in: number of coils        
2 short -2 short -1 or more short  When carriage is in                         
  spaced.........................                                              
                                   number of chokers                           
1 short..........................  When carriage is in: inspect rigging,       
                                   repair, and send back                       
2 short -2 short -4 short........  When carriage is in: slack haulback         
                                   and hold all lines until 1 short            
                                   is blown; then send back                    
3 short -3 short.................  When carriage is in: send back powder       
5 medium.........................  Tail rigger                                 
5 medium -4 short................  Tail rigger and his crew                    
3 medium.........................  Head hooker                                 
3 medium -4 short................  Second hooker and his crew                  
5 long...........................  Climber                                     
4 long...........................  Foreman                                     
1 long -1 short..................  Start or stop work                          
7 long -2 short..................  Man injured, call transportation and        
                                     stretcher                                 
1 long -1 short repeated.........  Fire                                        
 
 
SKIDDER WHISTLE SIGNALS

 
1 short.........................  Stops moving carriage. Stops or goes ahead on
                                  slack puller as case may be, if carriage is  
                                    stopped                                    
2 short.........................  Go ahead on skidding line holding carriage   
1 short -2 short................  Pick up skidding line, easy                  
2 short -1 short................  Shake up carriage to clear choker            
2 short -2 short................  Ahead on receding line                       
3 short.........................  Ahead on carriage, holding at present level, 
                                  using interlock                              
2 short -3 short -3 short.......  Ahead easy on skidding line                  
2 short -2 short -2 short.......  Slack skyline, cable down                    
2 short -2 short -2 short -1      Pick up skyline, cable up                    
  short.........................                                               
2 short -2 short -4 short.......  Slack receding line                          
2 short -4 short................  Slack skidding line                          
2 short -2 short -1 short.......  Tighten all lines                            
1 short -4 short................  Slack off slack puller                       
1 short -2 short................  Pick up slack puller when slack              
2 short -2 short -1 short.......  When carriage is in: to be                   
                                  used for number of chokers wanted            
2 short -2 short -1 long........  To be used for bull choker                   
1 short.........................  When carriage is in: inspect butt rigging    
2 short -4 short -1 short.......  For each additional 10 feet of long line     
1 long -1 short.................  Number of coils of strawline wanted          
5 medium........................  Tail or second rigger                        
5 medium -4 short...............  Tail or second rigger and his crew           
2 medium........................  Skidder head rigger                          
3 medium -4 short...............  Hooker and his crew                          
2 long..........................  Ahead on transfer                            
2 long -4 short.................  Slack transfer                               
1 short -3 short................  Ahead on carriage with slack puller line     
1 long..........................  Ahead on strawline                           
1 long -4 short.................  Slack strawline                              
1 long -3 short.................  Ahead easy on strawline                      
5 long..........................  Climber                                      
4 long..........................  Foreman                                      
1 long -1 short.................  Start or stop work                           
7 long -2 short.................  Man injured, call transportation and         
                                    stretcher                                  
1 long -1 short repeated........  Fire                                         
 
 
RUNNING SKYLINE WHISTLE SIGNALS

 
1 short.............................  STOP or DROP dropline                    
2 short.............................  Go ahead on dropline                     
1 short -2 short....................  Go ahead on dropline EASY                
2 short -2 short....................  Ahead on haulback                        
3 short-3 short.....................  Ahead on mainline                        
3 short.............................  Ahead on mainline EASY                   
2 short -2 short -2 short...........  Slack carriage                           
2 short -2 short -1 short...........  Tight line                               
1 long..............................  Ahead on strawline                       
1 long -4 short.....................  Slack strawline                          
1 long -3 short.....................  Ahead EASY on strawline                  
3 short.............................  When carriage in: strawline back on      
                                        haulback                               
1 long -1 short.....................  START or STOP WORK                       
4 long..............................  FOREMAN                                  
2 short -2 short -plus "X"            When carriage is in, number of           
  shorts............................                                           
                                      chokers WANTED                           
1 long -1 short -plus "X" shorts....  Number of strawline sections             
                                      WANTED                                   
 
 

Go BackGo Back to Article 17 Table of Contents