recovery button icon  Save Our Water icon


This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or warranty is made that the information is current or accurate. See full disclaimer at http://www.dir.ca.gov/od_pub/disclaimer.html.


Subchapter 4. Construction Safety Orders
Article 36. Fire Protection and Prevention

New query
§1938. Construction Site, General, Appendix A


Labor Code Excerpts; Accident Prevention Program Ideas; Etc.

PLATE A-1

LABOR CODE SECTIONS DEALING WITH DIVISION OF OCCUPATIONAL SAFETY AND HEALTH IN
GENERAL AS WELL AS CONSTRUCTION

Division 5. Safety in Employment
Part 1. Occupational Safety and Health
 
Chapter 1. Jurisdiction and Duties.......................    6300-6331  
Chapter 2. Education and Research........................    6350-6355  
Chapter 2.5 Hazardous Substances Information and Training               
                         Article                                        
 1. General Provisions...................................    6360-6363  
 2. Definitions..........................................    6365-6374  
 3. Hazardous Substances.................................    6380-6386  
 4. Duties...............................................   6390-6399.2 
 5. Liability and Remedies...............................  6399.5-6399.7
 Chapter 3. Responsibilities and Duties of Employers and                
Employees................................................   6400-6413.5 
Chapter 4. Penalties.....................................    6423-6436  
Chapter 5. Temporary Variances...........................    6450-6457  
Chapter 6. Permit Requirements...........................    6500-6511  
Chapter 7. Appeal Proceedings............................    6600-6633  
Chapter 8. Enforcement of Civil Penalties................    6650-6652  
Chapter 9. Miscellaneous Safety Provisions...............    6700-6715  
               Part 3. Safety on Buildings                              
    Chapter 1. Buildings Under Construction or Repair                   
                         Article                                        
 1. Floors and Walls.....................................    7100-7150  
 2. Scaffolding..........................................    7150-7158  
 3. Construction Elevators...............................    7200-7205  
 4. Structural Steel Framed Buildings....................    7250-7267  
  Chapter 3. Safety Devices Upon Buildings to Safeguard                 
Window Cleaners..........................................    7325-7332  
                    Chapter 5. Cranes                                   
                         Article                                        
 1. Permits for Tower Cranes.............................    7370-7374  
 2. Certification........................................    7375-7384  
 
 
Part 10. Use of Carcinogens
 
Chapter 1. General Provisions and Definitions....  9000-9009
Chapter 2. Exemptions............................    9015   
Chapter 3. Standards and Administration..........  9020-9022
Chapter 4. Reporting.............................  9030-9032
Chapter 5. Medical Examination...................    9040   
Chapter 6. Inspections...........................  9050-9052
Chapter 7. Penalties.............................  9060-9061
 
 
PLATE A-2 SUGGESTED SAFETY PROGRAM FOR CONTRACTORS GENERAL

1. Demonstrate your interest in safety by establishing a firm and positive accident prevention policy that includes the supplying of tangible items like hard hats, good ladders, first aid materials, and safety devices on equipment.

2. Provide that capable, responsible supervisors make regular inspections of all excavations, forms, scaffolds, stairs, ladders, structures, machinery, and equipment at frequent intervals; take immediate corrective measures to eliminate hazards directly under control of the employer, or report violations of Safety Orders and safe practices to the responsible employer.

3. Make certain that the foremen assume their share of the responsibility for accidents, and require a written report from them on each. Require that each report suggests a feasible means of avoiding future accidents of a similar nature.

4. Monthly, or more frequent, meetings of all foremen should be held under direction of the superintendent for a discussion of safety problems and accidents that have occurred. Have something specific ready for discussion, such as safety regulations, or any changes in equipment and methods that are to be adopted for safety reasons.

5. Display safety posters and warning signs. A sign indicating how many consecutive accident-free days have passed is often worthwhile.

6. Consider the advisability of posting a list of all foremen who have kept their crews accident free for a certain period of time.

7. Consider the advisability of establishing various forms of safety competition, including suitable rewards or recognition to individuals and crews with good records.

8. Require foremen to give individual safety instructions and orders, as needed, to new workers and those found to be working unsafely.

9. Consider the advisability of having the foremen call short "toolbox" or "tail-gate" safety meetings with their crews about once a week on the job, to emphasize some particular safety problem that needs special attention.

10. Keep track of your safety record and keep everyone posted as to progress. A graph or chart, indicating gains or losses, is good for this purpose.

11. Encourage safety suggestions from all workers and, if the suggestion cannot be followed promptly, explain why to the worker.

12. Consider the advisability of giving each worker a copy of certain important safety rules that they are expected to follow.

13. Arrange for frequent and regular field safety inspections.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

History

1. Amendment filed 4-3-85, effective thirtieth day thereafter (Register 85, No. 14).

2. Change without regulatory effect deleting appendices' introduction and index and amending Plate A-1 filed 6-14-93 pursuant to title 1, section 100, California Code of Regulations (Register 93, No. 25).

PLATE A-2-a ADVANCE PLANNING SUGGESTED FOR CONSTRUCTION WORK

Each operation of a construction job should be planned in advance. Such planning is needed at all stages of the project. It should start with the estimators, prior to preparations of bids, and continue throughout the job, with superintendents and foremen doing their share.

Construction planning will eliminate some accidents automatically, by creating a well-organized job. But expert planning gives special attention to safety, and thus is highly effective in making the operation safe and efficient.

1. Safe Access and Movement

 (a) Workers 


 (1) Adequate work areas. 


 (2) Adequate walkways and runways. 


 (3) Adequate ladders, stairways, or elevators. 


 (4) Work areas and passageways clear of rubbish, debris, nails, etc. 


 (5) Protection for floor and roof openings. 


 (6) Adequate illumination. 


 (b) Vehicles 


 (1) Good roads. 


 (A) Adequate turn space. 


 (B) Adequate parking area. 


 (C) Free from excessive mud and dump areas. 


 (2) Separate materials storage areas and dump areas. 


 (3) Adequate signs, signals, etc., to route vehicles on job. 


 (4) Maintenance and repair of vehicles. 


 (c) Location of Utilities and Service 


 (1) Locate saw, tool sheds, office, etc., in a safe, convenient place. 


 (2) Consider location of high-voltage lines. 


 (A) Arrange to move, de-energize, or erect barrier, if contact is a possibility. 


 (3) Locate sanitary facilities, drinking water, power, etc., for safety and convenience. 


2. Schedule Work for Safety

 (a) Have safety materials on job when needed, i.e., personal protective equipment, shoring, first aid, etc. 


 (b) Plan work so that too many trades are not in a small area at the same time. 


3. Work Procedures

 (a) Materials Handling 


 (1) Methods of elevating and handling materials. 


 (A) Adequate space. 


 (B) Proper auxiliary equipment, i.e., cranes, hoists, elevators, trucks, etc. 


 Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code. 


 History 


1. Amendment filed 4-3-85; effective thirtieth day thereafter (Register 85, No. 14).

PLATE A-2-b

 (2) Methods of loading and unloading. 


 (A) Adequate space. 


 (B) Proper auxiliary equipment, i.e., power shovels, cranes, rigging, fork lifts, etc. 


 (b) Tools and Equipment 


 (1) Repair, maintenance, and care. 


 (2) Inspection. 


 (3) Adequate supplies of the right tools for each part of job. 


 (c) Workers and Foremen 


 (1) Proper job placement. 


 (2) Adequate training and supervision. 


 (3) Adequate manpower. 


 (4) Plans for maintaining interest in safety. 


 (A) Safety bulletins, record charts, and posters. 


 (B) Recognition for groups or individuals with safety records. 


 (C) Investigation and reporting on all accidents. 


 (D) Knowledge of safety orders. 


 (E) Safety meetings. 



wear your hard hat

Image 1 (8.5" X 6.75") Not available for Offline Print to STP or FAX

A RULE BREAKER IS AN ACCIDENT MAKER

 Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code. 


 History 


1. New NOTE filed 4-3-85; effective thirtieth day thereafter (Register 85, No. 14).

2. Change without regulatory effect providing more legible illustrations filed 8-4-2008 pursuant to section 100, title 1, California Code of Regulations (Register 2008, No. 32).

PLATE A-3 CODE OF SAFE PRACTICES

(This is a suggested code. It is general in nature and intended as a basis for preparation by the contractor of a code that fits his/her operations more exactly.)

GENERAL

1. All persons shall follow these safe practices rules, render every possible aid to safe operations, and report all unsafe conditions or practices to the foreman or superintendent.

2. Foremen shall insist on employees observing and obeying every rule, regulation, and order as is necessary to the safe conduct of the work, and shall take such action as is necessary to obtain observance.

3. All employees shall be given frequent accident prevention instructions. Instructions shall be given at least every 10 working days. When applicable, the accident prevention instructions shall also include specific instruction on the safe use, care and maintenance of fall protection equipment (i.e. fall arrest systems, positioning device systems, safety nets, etc.) used at the jobsite.

4. Anyone known to be under the influence of drugs or intoxicating substances which impair the employee's ability to safely perform the assigned duties shall not be allowed on the job while in that condition.

5. Horseplay, scuffling, and other acts which tend to have an adverse influence on the safety or well-being of the employees shall be prohibited.

6. Work shall be well planned and supervised to prevent injuries in the handling of materials and in working together with equipment.

7. No one shall knowingly be permitted or required to work while the employee's ability or alertness is so impaired by fatigue, illness, or other causes that it might unnecessarily expose the employee or others to injury.

8. Employees shall not enter manholes, underground vaults, chambers, tanks, silos, or other similar places that receive little ventilation, unless it has been determined that it is safe to enter.

9. Employees shall be instructed to ensure that all guards and other protective devices are in proper places and adjusted, and shall report deficiencies promptly to the foreman or superintendent.

10. Crowding or pushing when boarding or leaving any vehicle or other conveyance shall be prohibited.

11. Workers shall not handle or tamper with any electrical equipment, machinery, or air or water lines in a manner not within the scope of their duties, unless they have received instructions from their foreman.

12. All injuries shall be reported promptly to the foreman or superintendent so that arrangements can be made for medical or first aid treatment.

13. When lifting heavy objects, the large muscles of the leg instead of the smaller muscles of the back shall be used.

14. Inappropriate footwear or shoes with thin or badly worn soles shall not be worn.

15. Materials, tools, or other objects shall not be thrown from buildings or structures until proper precautions are taken to protect others from the falling objects.

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

History

1. Amendment filed 4-3-85; effective thirtieth day thereafter (Register 85, No. 14).

2. Amendment of first paragraph and provision number 3. filed 7-30-97; operative 8-29-97 (Register 97, No. 31).

PLATE A-3-a

16. Employees shall cleanse thoroughly after handling hazardous substances, and follow special instructions from authorized sources.

17. Hod carriers should avoid the use of extension ladders when carrying loads. Such ladders may provide adequate strength, but the rung position and rope arrangement make such climbing difficult and hazardous for this trade.

18. Work shall be so arranged that employees are able to face ladder and use both hands while climbing.

19. Gasoline shall not be used for cleaning purposes.

20. No burning, welding, or other source of ignition shall be applied to any enclosed tank or vessel, even if there are some openings, until it has first been determined that no possibility of explosion exists, and authority for the work is obtained from the foreman or superintendent.

21. Any damage to scaffolds, falsework, or other supporting structures shall be immediately reported to the foreman and repaired before use.

USE OF TOOLS AND EQUIPMENT

22. All tools and equipment shall be maintained in good condition.

23. Damaged tools or equipment shall be removed from service and tagged "DEFECTIVE."

24. Pipe or Stillson wrenches shall not be used as a substitute for other wrenches.

25. Only appropriate tools shall be used for the job.

26. Wrenches shall not be altered by the addition of handle-extensions or "cheaters."

27. Files shall be equipped with handles and not used to punch or pry.

28. A screwdriver shall not be used as a chisel.

29. Wheelbarrows shall not be pushed with handles in an upright position.

30. Portable electric tools shall not be lifted or lowered by means of the power cord. Ropes shall be used.

31. Electric cords shall not be exposed to damage from vehicles.

32. In locations where the use of a portable power tool is difficult, the tool shall be supported by means of a rope or similar support of adequate strength.

MACHINERY AND VEHICLES

33. Only authorized persons shall operate machinery or equipment.

34. Loose or frayed clothing, or long hair, dangling ties, finger rings, etc., shall not be worn around moving machinery or other sources of entanglement.

35. Machinery shall not be serviced, repaired or adjusted while in operation, nor shall oiling of moving parts be attempted, except on equipment that is designed or fitted with safeguards to protect the person performing the work.

<General Materials (GM) - References, Annotations, or Tables>


    Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.  


 HISTORY 
   
1. Amendment filed 4-3-85; effective thirtieth day thereafter (Register 85, 
No. 14).

 PLATE A-3-b 
   
36. Where appropriate, lock-out procedures shall be used.

37. Employees shall not work under vehicles supported by jacks or chain hoists,
without protective blocking that will prevent injury if jacks or hoists should
fail.

38. Air hoses shall not be disconnected at compressors until hose line has been
bled.

39. All excavations shall be visually inspected before backfilling, to ensure
that it is safe to backfill.

40. Excavating equipment shall not be operated near tops of cuts, banks, and
cliffs if employees are working below.

41. Tractors, bulldozers, scrapers and carryalls shall not operate where there
is possibility of overturning in dangerous areas like edges of deep fills, cut
banks, and steep slopes.

42. When loading where there is a probability of dangerous slides or movement
of material, the wheels or treads of loading equipment, other than that riding
on rails, should be turned in the direction which will facilitate escape in
case of danger, except in a situation where this position of the wheels or
treads would cause a greater operational hazard.

 BLASTING OPERATIONS 
  
1. Cases that have contained explosives shall be destroyed by burning out-of-
doors. Do not burn in a stove or furnace.

2. Shoes with nails or metal plates shall not be worn in magazines or near
explosives.

3. Blasting caps shall only be carried in approved containers.

4. The least amount of proper strength explosive that will do the job
effectively shall be used.

5. Detonators and primers shall be separated from the explosives until it is
necessary to bring them together in preparing for the blast.

6. Holes loaded during a shift should be fired during that shift.

7. The operations of loading and firing should be carried out with as few
workers as possible.

8. Drill holes shall be blown out and made ready before explosives are brought
to the site.

9. In tamping explosives, steady, even pressure should be used.

10. For electric blasting, the following shall apply:

(a) Tight electrical connections.

(b) No short circuits or breaks in the wires.

(c) Enough current to fire all shots.

(d) A strong, properly-applied force when using a blasting machine operated by
physical effort.

(e) Care not to damage the insulation of wires when tamping charges.

11. If misfires occur, the licensed blaster shall be contacted.

Note: Authority cited: Section 142.3, Labor Code. Reference: 
Section142.3, Labor Code.

History
 
1. Amendment filed 4-3-85; effective thirtieth day thereafter (Register 85, 
No. 14).

2. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, 
No. 39).

 PLATE A-3-c ROOFING OPERATIONS 
  
1. Knotted hand lines should not be used.

2. Roofers tending kettles, or carrying buckets of hot tar, shall wear gloves
that fit snugly at the wrists, and long sleeved shirts fastened at the wrists.

3. At no time should a roofer, while handling or exposed to injury from hot
tar, work without a shirt or appropriate footwear.

4. Appropriate portable fire extinguishers shall be kept at or near the kettle,
attached, if practicable, to the tongue of the kettle, away from the danger
zone.

5. Kettle covers should be equipped with a handle that projects at least
fourteen inches (14 ") away from the surface of the cover or lid.

6. Kettle covers shall be closed and latched when in transit and the kettle
should be slop-proof when cover is closed.

7. When parked, means shall be provided to prevent inadvertent movement of the
kettle.

8. Ladders should be used with great caution, and roof gutters should not be
depended upon for support.

9. Workers handling buckets of hot tar should not carry anything that will
interfere with the safety of this operation.

10. The gallows frame shall be securely anchored before hoisting materials.

11. Only muscular power shall be used to hoist materials by means of a gallows
frame. A winch or power hoist shall not be used.

Note: Authority cited: Section 142.3, Labor Code. Reference: 
Section142.3, Labor Code.

History
 
1. Repealer of Item No. 58 and renumbering of Item Nos. 59-61 filed 6-6-80;
effective thirtieth day thereafter (Register 80, No. 23).

2. Amendment filed 4-3-85; effective thirtieth day thereafter (Register 85, 
No. 14).

Go BackGo Back to Article 36 Table of Contents